HP24100ULWP, HP28100ULWP Product Installation Document —
P/N 53434:A 9/9/08
– Ground to terminal marked “G”
8. Connect CCTV cameras (or other external loads) to output terminals on the power supply. Maintain a 1/4” separation
between factory wiring and all AC field wiring.
9. After wiring is complete, restore power to the branch circuit.
10. Verify that all connections are correct and that the load current does not exceed output limitations.
11. After installation is complete, secure cabinet door to prevent unauthorized access.
!
WARNING:TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE. RISK OF ELECTRICAL SHOCK AND/OR
EQUIPMENT DAMAGE, DISCONNECT POWER BEFORE SERVICING THIS APPLIANCE.
• FOR CONTINUOUS PROTECTION AGAINST HAZARD, REPLACE FUSES WITH
ONLY EXACT TYPE AND RATING.
•
MAINTAIN A 1/4” OF SEPARATION BETWEEN THE AC MAINS AND ALL LOW
VOLTAGE WIRING.
• A READILY ACCESSIBLE SWITCHED CIRCUIT BREAKER MUST BE AVAILABLE
TO DISCONNECT MAIN POWER AS REQUIRED.
• THIS UNIT CONTAINS NO USER SERVICEABLE PARTS, INSTALLATION AND
SERVICING SHOULD ONLY BE MADE BY QUALIFIED PERSONNEL.
• INSTALL IN ACCORDANCE WITH ALL LOCAL REGULATIONS AND NATIONAL
ELECTRIC CODE.