background image

It is important that the installation instructions below are followed for successful installation of this 

portable air conditioner. Please call Customer Support if you have any difficulties or queries regarding 

these installation procedures.

1. Locate and snap the 2 half pieces of the Window Bracket Panel Adapter securely together. Install 

onto the plastic hose by rotating anti-clockwise over the plastic hose. Install and rotate (anti-clock-
wise) the hose connector over the opposite end of the plastic hose. Ensure secure fit on both ends.

2. Adjust the window bracket as per width or 

height of your window and insert the plastic 
pin to fix at the desired position. There is a 
hole where the Plastic Hose will be inserted 
later. Make sure this hole is not blocked.

3. Connect the plastic hose to the hose 

connector on back of the unit. Slide-in the 
hose connector downwards until it is locked 
in place.

4. Connect the window bracket to the window 

bracket panel adapter. Ensure that all 
connections are tight and installed properly.

Note:

After setting the window bracket to the size of your 

window, please remove it from the window and 

follow the instructions below.

INSTALLATION

1.
2.
3.
4.
5.
6.

Window Bracket Kit.............................
Window Bracket Panel Adapter..........
Plastic Pin............................................
Hose Connector..................................
Plastic Hose........................................
Drain Tube (refer to Continuous 
Draining for Dehumidifier Mode)..........

Installation Kit:

Installation Steps:

1 Set
2 Half Pieces
1 Piece
1 Piece
1 Piece

1 Piece

Plastic Pin

Hole for Window Bracket
Panel Adapter & Plastic Hose

26.6", 33.1" to 49.6"
(67.5cm, 84cm to 126cm)

5. Connect the window bracket to the window.

6. The Portable Air Conditioner is now ready to use.

EN

3

Plastic Hose: 
Dia. 5.9" (15cm)
Length: 14.2" to 47.2" (36cm to 120cm)

o

C

o

F

COOL

DRY

FAN

POWER

TIMER

SLEEP
WATER

FULL

HIGH

MID

LOW

TIMER

SLEEP

o

C

o

F

COOL

DRY

FAN

POWER

TIMER

SLEEP
WATER

FULL

HIGH

MID

LOW

TIMER

SLEEP

1

2

x 2

5

x 1

x 1

3

x 1

x 1

4

6

x 1

=

Summary of Contents for HL10CESWB

Page 1: ...0CESWK HL10CESWG HL10CESWB HL12 Series HL12CESWW HL12CESWK HL12CESWG HL12CESWB HL14 Series HL14CESWW HL14CESWK HL14CESWG HL14CESWB HL14CHESWW HL14CHESWK HL14CHESWG HL14CHESWB Customer Support USA 1 800 474 2147 CANADA 1 888 209 0999 Canada Customer Support service available for models sold in Canada only Email usinfo jmatek com Web www jmatek com Portable Air Conditioner User Manual Read and save ...

Page 2: ...heat outside The air conditioner includes a window venting kit No permanent installation is needed The unit is easy to move from room to room and offers a truly flexible air conditioning solution Auto Evaporation System The unit automatically evaporates the condensate through the air outlet hose There is no need to empty the drainage tank except in very humid conditions Read and follow the instruc...

Page 3: ... gasoline paint or other flammable goods are stored Basic safety precautions should always be followed when using electrical appliances This household appliance has been manufactured for use in domestic environments and should not be used for other purposes Only use the installation kit provided to install this unit DO NOT attempt to extend the exhaust hose or install this unit using other methods...

Page 4: ...de in the hose connector downwards until it is locked in place 4 Connect the window bracket to the window bracket panel adapter Ensure that all connections are tight and installed properly Note After setting the window bracket to the size of your window please remove it from the window and follow the instructions below INSTALLATION 1 2 3 4 5 6 Window Bracket Kit Window Bracket Panel Adapter Plasti...

Page 5: ...ast 50 cm 20 inches away from the wall Do not place the unit in front of curtains or drapes as this could obstruct the airflow USE OPERATION CONTROL PANEL 1 Power Control 2 Indicator Lights 3 Timer Control Sleep Control 4 Timer Temperature Set Controls 5 Mode Control 6 Fan Speed Control Model with Heat Mode Model without Heat Mode FUNCTION BUTTONS EN 4 MIN 55 5 cm 50 cm 20 RECOMMENDED NOT RECOMMEN...

Page 6: ...outside the room when using heating mode Sleep Mode SLEEP When the Sleep Mode is activated in Air Conditioning mode the set temperature will increase by 1 F or 1 C after the first hour of cooling and will increase a further 1 F or 1 C after the second hour of cooling The unit will maintain this temperature for 5 hours The set temperature will then reduce by 1 F or 1 C on the seventh hour and reduc...

Page 7: ...e in the unit If the bottom internal tank is 50 full the WATER FULL light will illuminate If the bottom internal tank is 100 full an alarm will beep for 30 seconds The unit will not operate until the water has been drained from the bottom drain plug refer to Water Condensa tion Drainage After switching the air conditioner off the compressor will not start immediately You must wait about 3 minutes ...

Page 8: ...art 15 of the FCC Rules Operation is subject to following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to pr...

Page 9: ...st Replace the Upper Grill onto the unit and reinstall the Lower Grill with the screws End of Season Storage Maintenance If the appliance will not be used for a long time 1 2 3 4 5 6 7 8 Be sure to drain the left over water condensation Remove the lower drain plug and use a shallow pan to collect the water make sure to replace the drain plug when finished To dry excess moisture run the unit in Fan...

Page 10: ...ce Place a shallow pan under the lower rubber drain plug See diagram Remove the rubber drain plug Water will drain out and collect in the shallow pan After the water is drained replace the rubber drain plug You can now turn on the unit 1 2 3 4 5 6 Unplug the unit from the power source Remove the upper lower rubber drain plug Some residual water may spill so please have a pan to collect the water C...

Page 11: ...operly connected Connect exhaust hose as per instructions on page 4 Runs but not cooling A door or window is open The air filter is dirty The exhaust hose is detached Temperature setting is too high Air outlet or intake is blocked Room exceeds recommended size Large size or number of windows are decreasing cooling effectiveness Make sure the window or door is closed Clean the air filter Reinstall ...

Page 12: ...nternational Inc Honeywell International Inc makes no representations or warranties with respect to this product This product is manufactured by Airtek Int l Corp Ltd subsidiary of JMATEK Ltd JMATEK North America LLC Mahwah New Jersey 07495 USA Phone 1 800 474 2147 Email usinfo jmatek com Web www jmatek com Customer Support USA 1 800 474 2147 CANADA 1 888 209 0999 Canada Customer Support service a...

Reviews: