6. Operation
6.1 Checking before use
Before using the sampler :
Check the good state of the device.
Check the cleanliness of the unit (sampler and bottle) to prevent any contamination of the
sample.
Inspect the bottle tape end for breaks, kinks and wear. If there is some damage, replace the
tape before use.
Check of the attachment of the hook locking device on the tape.
Check the closure of the hook locking device according to Fig. 1. The swivel hook has to be
locked in use.
Nota: Clean the instrument of any excess of liquid after use. Remove the carter winder and clean
the storage tube. This cleaning must be done very properly, in particular when corrosive liquids are
gauged, such as strong acids or caustic soda for instance.
Store the instrument in a dry location.
Tape inspection
Fig. 1
Hook Locked
Hook Unlocked