background image

Checking 

 

 

The batteries have to be replaced when the red 
LED at the room unit HCW 80 flashes (see 
section “8 Changing batteries”). 

 

 

Remove the batteries. 

 

Mark the drill holes according to the drilling template 
(see Fig. 11). 

 

 

 

Fig. 11: Drilling scheme (measurements in mm) 

 

 

Drill the holes. 

 

Screw on the room unit. 

 

Re-insert the batteries. 

 

Place the housing cover in 
position above and snap it down 
(see Fig. 12).

 

Fig. 12: Placing housing 
cover in position 

 

 

3.3. 

Teach-in (single devices only) 

The teach-in operation is required if the relay module 
HC60NG and the room unit HW80 is not bounded e.g. new 
single devices or product replacement. 

 

 

3.3.1. 

Assignment to the relay module 
HC60NG 

After the power up of the relay module HC60NG the red 
LED will start to flash at  0,1 sec on/ 0,9 sec off. 
If it is not the case set the HC60NG into the reset mode see 
section “6 Factory reset of relay module HC60NG”. 

 

Press and hold the teach-in button of the HC60NG for  
5 sec to enter into the teach-in mode.

 

The red LED flashing at 0.5 sec on/0.5 sec off confirms 
the teach-in mode has been entered.

 

 

Press the teach-in button of the 

HCW 80

 to send the 

binding signal to the HC60NG.

 

The red LED of the HC60NG is switched off to confirm a 
successful teach-in operation.  

The time out is after 5 min. 

 

3.3.2. Failed 

teach-in 

 

If the teach-in has failed: 

 

 See section “3.3.1 Assignment to the relay module 
HC60NG”.

 

 

Improve the data transfer.

 

 

Improving the data transfer 

 

When selecting the operating site of each device ensure 
that the distance to radio devices such as radio 
headphones, cordless phones, etc. according to the DECT 
standard amounts to at least 1 m. 

 

Do not install the devices over metallic wall connecting 
sockets and at least 30 cm away from the cover of the heat 
generator. 

 

Correct the installation site of the room unit HCW 80 if 
necessary. 

 

4. Checking 

 

4.1. System 

check 

 

Adjust the set point of the room unit HCW 80 to 30 °C. 

The relay module HC60NG is switched on. 

 

Change the set point of the room unit HCW 80 to 5 °C.  

The relay module HC60NG is switched off. 

 

4.2.  Radio transmission check 

The room unit HCW 80 can send a test signal to the 
assigned relay module HC60NG in order to test the signal 
strength. 

 

Keep the teach-in button of the HCW 80 pressed for at 
least 15 sec until the red LED of the HCW 80 extinguishes. 

The HCW 80 is now in test mode and sends a test signal 
every 5 sec. 
The LED of the HCW80  flashes briefly at every test 
signal the HCW 80 is sending. 

When the green LED of the HC60NG flashes every 5 sec, 
the wireless communication is proceeding successfully. 
The field strength is indicated by flashing of the red LED of 
the HC60NG (1 = sufficient, 5 = strong). 

Summary of Contents for HCW 80

Page 1: ...HCW 80 Wireless Room Thermostat Y6630D1007 Installation and Operation ...

Page 2: ......

Page 3: ...terference of the relay module HC60NG in the device through metallic objects or further frequency devices Mount the device with a distance of at least 30 cm to metallic objects such as wall boxes or boiler housings according to the DECT standard etc Do not mount on metal wall boxes 2 Overview The room unit HCW 80 is used for intelligent room temperature control It controls a single heating system ...

Page 4: ...the terminal covers 7 mm Æ 7 mm Æ Fig 4 Connecting the relay module to the power supply max 2 5 mm2 Fig 5 Wiring the terminal Caution Incorrect wiring Install in accordance with local wiring regulations Observe ambient temperature and current limits see HC60NG wiring label ...

Page 5: ...sufficient distance to metallic objects Mount the device with a distance of at least 1 m to radio devices such as radio headphones cordless phones according to the DECT standard etc Select another installation site if the radio interference cannot be rectified Fig 8 Positioning the room unit HCW 80 Place the room unit HCW 80 at the installation site but do not install it yet Remove the housing cov...

Page 6: ...in operation The time out is after 5 min 3 3 2 Failed teach in If the teach in has failed See section 3 3 1 Assignment to the relay module HC60NG Improve the data transfer Improving the data transfer When selecting the operating site of each device ensure that the distance to radio devices such as radio headphones cordless phones etc according to the DECT standard amounts to at least 1 m Do not in...

Page 7: ...e adjustment dial see Fig 13 7 2 Limiting the adjustment range You can limit the adjustment range that can be used at the adjustment dial Remove the housing cover see Fig 9 Page 5 Fig 14 Limiting the adjustment range Place the two small pins into the holes of the adjustment dials in order to limit the adjustment range see Fig 14 Orientate yourself on the basis of the inner scale In Fig 14 the pins...

Page 8: ...80 see section 8 9 2 Technical data Batteries 1 5 V type LR06 AA Frequency 868 3 MHz transmitter Operating temperature 0 C to 50 C Storage temperature 20 C to 70 C Humidity 5 to 90 relative humidity 9 3 Device and function definition in accordance with EN 60730 1 Purpose of the device is temperature controlling Device fulfils Protection class 1 EN 60730 1 Independently installable electronic contr...

Page 9: ......

Page 10: ...ywell com The right is reserved to make modifications This document is definitive for the enclosed product and replaces all previous publications Honeywell Inc hereby declares that this device complies with the basic requirements and other relevant regulations of guideline 1999 5 EC The declaration of conformity of the product can be requested from the manufacturer Note to non EU countries This pr...

Reviews: