2 | High Resolution Indoor Box Camera
www.honeywell.com/security
+1.800.323.4576 (North America only)
https://www.honeywellsystems.com/ss/techsupp/index.html
© 2013 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any
means without written permission from Honeywell. The information in this publication is believed to be accurate
in all respects. However, Honeywell cannot assume responsibility for any consequences resulting from the use
thereof. The information contained herein is subject to change without notice. Revisions or new editions to this
publication may be issued to incorporate such changes.
Document 800-15951 – Rev A – 09/2013
Installing the Lens
1.
Remove the lens mount cap
from the camera (if present).
2.
Screw the lens clockwise
onto the lens mount of the
camera (A). If you are using a
C-mount lens, you will need
to attach the C-mount
adapter first.
3.
Connect the auto-iris drive
cable to the 4-pin connector
interface on the side of the
camera (B).
Connecting the Wiring
Note
Do not turn on the power of any connected equipment until all
connections are completed.
1.
Connect the power input of
the camera to an external
12 V DC or 24 V AC power
supply.
2.
Connect the video output of
the camera to the video input
of your monitor.
3.
Optionally, make alarm input
and output connections.
Alarm input is active when
shorted to ground. Alarm out
is open collector controlled by
alarm in. Absolute maximum
alarm out values are 12 V DC
and 200 mA.
4.
Optionally, connect the D/N input of the camera to an external day/night
control and set the OSD Day/Night menu to EXT1 or EXT2. When the
D/N terminal is connected to the ground (G) terminal, the camera is
forced into night mode. The camera remains in night mode until the D/N
terminal is disconnected from the ground (G) terminal.
5.
Optionally, connect a DVR or keyboard using the RS-485 terminals
(D+, D–). Connect T+,T– of the DVR or keyboard to D+, D– of the
camera. The default baud rate is 4800, address is 001, and protocol is
Pelco-D.
Note
The camera address cannot be changed. Only one camera address is
supported.
Mounting the Camera
The camera can be installed to a tripod, housing, wall mount, or ceiling mount
using the 1/4–20 UNC mounting holes on the top and bottom of the camera.
Adjusting the Lens
After installing the lens and connecting the wiring, you can adjust the lens focus
and zoom. If the correct focus cannot be obtained, you can adjust the back
focus manually using the back focus screw on the side of the camera.
To adjust the back focus:
1.
Fully open the iris, set the zoom ring (if applicable) to full WIDE, set the
focus ring to NEAR.
2.
Loosen the back focus screw, adjust the back focus ring to focus the
picture, and then retighten the back focus screw.
Configuring the Camera
After you have installed the lens, connected the wiring, mounted the camera,
and adjusted the lens focus and zoom, you can configure the camera settings
using the on-screen display (OSD) setup menu.
For more information about setting up the camera, refer to the
High Resolution
Indoor Box Camera User Guide
(800-15952).
A
B
Power input
(12 V DC or 24 VAC)
Video output
Alarm I/O
D/N input
RS-485
Specifications
Video Standard
NTSC, PAL
Image Sensor
1/3-inch interline transfer CCD
Number of Pixels (H×V)
HCC10(X): 768 × 494 (NTSC); 752 × 582 (PAL)
HCC210(X): 976 × 494 (NTSC); 976 × 582 (PAL)
Minimum Illumination
0.1 lux color @ F1.2, 50 IRE, AGC on
Horizontal Resolution
HCC10(X): 600 TVL
HCC210(X): 650 TVL
Video Output
1.0
V
p-p, 75 ohms
Sync System
Internal, line lock
S/N Ratio
50 dB or more (AGC off)
Auto Gain Control
6 dB to 44.8 dB (Manual)
Automatic Electronic Shutter
1/60–1/100,000 s (NTSC)
1/50–1/100,000 s (PAL)
White Balance
ATW/Push/User1/User2/AntiCR/Manual/Push Lock
BLC/HLC
Off/BLC/HLC
Day/Night
Auto/Day/Night/Ext1/Ext2
Noise Reduction
Y reduction
Motion Detection
Off/On; 4 programmable zones
Privacy Masking
Off/On; 8 programmable zones
Input Voltage
12 V DC/24 V AC (±10%)
Power Consumption
4 W (max)
Dimensions (L×W×H))
4.4
ʺ
× 2.7
ʺ
× 2.2
ʺ
(111.0 mm × 68.8 mm × 56.0 mm)
Weight
0.88 lb (0.4 kg)
Camera Mount
1/4-20 UNC
Lens Mount
C/CS Mount
Connectors
Lens: 4-pin connector
Video Output: BNC connector
Power Input: 2-pin terminal block
Alarm/DN/RS-485: 6-pin terminal block
Temperature
Operating: 14°F to 122°F (–10°C to 50°C)
Storage: –4°F to 140°F (–20°C to 60°C)
Relative Humidity
Less than 90%, non-condensing
3.9 (100 mm)
4.4 (111 mm)
2.7 (68.8 mm)
2.2