Installing the Lens

1.

Remove the lens mount cap 
from the camera (if present).

2.

Screw the lens clockwise 
onto the lens mount of the 
camera (A). If you are using a 
C-mount lens, you will need 
to attach the C-mount 
adapter first.

3.

Connect the auto-iris drive 
cable to the 4-pin connector 
interface on the side of the 
camera (B).

Connecting the Wiring

Note   

Do not turn on the power of any connected equipment until all 

connections are completed.

1.

Connect the power input of 
the camera to an external 
12 V DC or 24 V AC power 
supply.

2.

Connect the video output of 
the camera to the video input 
of your monitor. 

3.

Optionally, make alarm input 
and output connections. 
Alarm input is active when 
shorted to ground. Alarm out 
is open collector controlled by 
alarm in. Absolute maximum 
alarm out values are 12 V DC 
and 200 mA.

4.

Optionally, connect the D/N input of the camera to an external day/night 
control and set the OSD Day/Night menu to EXT1 or EXT2. When the 
D/N terminal is connected to the ground (G) terminal, the camera is 
forced into night mode. The camera remains in night mode until the D/N 
terminal is disconnected from the ground (G) terminal. 

5.

Optionally, connect a DVR or keyboard using the RS-485 terminals 
(D+, D–). Connect T+,T– of the DVR or keyboard to D+, D– of the 
camera. The default baud rate is 4800, address is 001, and protocol is 
Pelco-D.

Note   

The camera address cannot be changed. Only one camera address is 

supported.

Mounting the Camera

The camera can be installed to a tripod, housing, wall mount, or ceiling mount 
using the 1/4–20 UNC mounting holes on the top and bottom of the camera.

Adjusting the Lens

After installing the lens and connecting the wiring, you can adjust the lens focus 
and zoom. If the correct focus cannot be obtained, you can adjust the back 
focus manually using the back focus screw on the side of the camera.

To adjust the back focus:

1.

Fully open the iris, set the zoom ring (if applicable) to full WIDE, set the 
focus ring to NEAR.

2.

Loosen the back focus screw, adjust the back focus ring to focus the 
picture, and then retighten the back focus screw. 

Configuring the Camera

After you have installed the lens, connected the wiring, mounted the camera, 
and adjusted the lens focus and zoom, you can configure the camera settings 
using the on-screen display (OSD) setup menu.

For more information about setting up the camera, refer to the 

High Resolution 

Indoor Box Camera User Guide

 (800-15952).

A

B

Power input
(12 V DC or 24 VAC)

Video output

Alarm I/O
D/N input

RS-485

Specifications

Video Standard

NTSC, PAL

Image Sensor

1/3-inch interline transfer CCD

Number of Pixels (H×V)

HCC10(X): 768 × 494 (NTSC); 752 × 582 (PAL)
HCC210(X): 976 × 494 (NTSC); 976 × 582 (PAL)

Minimum Illumination

0.1 lux color @ F1.2, 50 IRE, AGC on

Horizontal Resolution

HCC10(X): 600 TVL
HCC210(X): 650 TVL

Video Output

1.0 

V

p-p, 75 ohms

Sync System

Internal, line lock

S/N Ratio

50 dB or more (AGC off)

Auto Gain Control

6 dB to 44.8 dB (Manual)

Automatic Electronic Shutter

1/60–1/100,000 s (NTSC)
1/50–1/100,000 s (PAL)

White Balance

ATW/Push/User1/User2/AntiCR/Manual/Push Lock

BLC/HLC

Off/BLC/HLC

Day/Night

Auto/Day/Night/Ext1/Ext2

Noise Reduction

Y reduction

Motion Detection

Off/On; 4 programmable zones

Privacy Masking

Off/On; 8 programmable zones

Input Voltage

12 V DC/24 V AC (±10%)

Power Consumption

4 W (max)

Dimensions (L×W×H))

4.4

ʺ

 × 2.7

ʺ

 × 2.2

ʺ

 (111.0 mm × 68.8 mm × 56.0 mm)

Weight

0.88 lb (0.4 kg)

Camera Mount

1/4-20 UNC

Lens Mount

C/CS Mount

Connectors

Lens: 4-pin connector
Video Output: BNC connector
Power Input: 2-pin terminal block
Alarm/DN/RS-485: 6-pin terminal block

Temperature

Operating: 14°F to 122°F (–10°C to 50°C)
Storage: –4°F to 140°F (–20°C to 60°C)

Relative Humidity

Less than 90%, non-condensing

3.9 (100 mm)

4.4 (111 mm)

2.7 (68.8 mm)

2.2