H46C HUMIDITY CONTROLLER 

H46C 

HUMIDITY  CONTROLLER 
RISE 

DEHUMIDIFIER 

L1 

EXHAUST FAN 

(HOT) 

OR AIR 

POWER 

CONDITIONER 

SUPPLY 

L2 

PROVIDE DISCONNECT MEANS AND OVERLOAD 

M7923

PROTECTION AS REQUIRED. 

Fig. 2. Typical H46C wiring diagram. 

Connections and Operation 

A dehumidistat in combination with the thermostat can be 

used to run the air conditioner to control relative humidity 
levels. The dehumidistat and thermostat can be wired in 

parallel or in series. 

Wiring in parallel allows the dehumidistat to indepen­

dently control the humidity level, but could cause 

overcooling of the home. During unoccupied times, the 

homeowner should set the thermostat to a relatively high 

setting and control moisture using the dehumidistat. 

Wiring in series prevents overcooling but the air 
conditioner runs only when both the thermostat and 
dehumidistat are calling. During unoccupied times, the 

homeowner should set the thermostat to a relatively low 
setting and control moisture using the dehumidistat. 

SETTING AND ADJUSTMENT 

The H46 makes contact on a relative humidity rise to the 

setpoint to start the dehumidifier. On a decrease in 
relative humidity to the setpoint (minus the differential), 
the switch breaks contact to stop the dehumidifier. Turn 

the knob clockwise to the setting stop to place the H46 in 

the On position. Turn the knob counterclockwise to the 

setting stop to place the H46 in the Off position. 

CHECKOUT 

After completing all mounting and wiring, turn on the 

power supply. Place the system into operation by turning 

the setting knob toward the low end of the scale until the 

dehumidifier motor starts. Turn the setting knob slowly 

toward the high end of the scale until the dehumidifier 

motor stops. 

H46C 

T87F/Q539A INTERNALSCHEMATIC 

TEMPERATURE 
FALL 

PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS 
AS REQUIRED. 

HEATING DAMPER MOTOR, IF USED. 

CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION. 

B

R1 

W1 

Y1 

R

H

HEAT 

OFF 

FAN

AUTO 

ON

COOL 

HEAT 

OFF 

COOL 

FIXED 
COOL 
ANTICIPATOR 

ADJUSTABLE 
HEAT 
ANTICIPATOR 

HEATING 
RELAY OR 
VALVE COIL 

COOLING 
CONTACTOR 
COIL 

FAN RELAY 
COIL 

FILTER 
LIGHT 

T87F 

M7913 

Fig. 3. Typical parallel wiring hookup for H46C with T87F/Q539A combination

for dehumidification and mildew control. 

95-5367-4 

Summary of Contents for H46C

Page 1: ...Mounting 1 Remove the setting knob 2 To remove cover pull cover forward from device 3 Install a 2 in x 3 in 51 mm x 76 mm vertical switch box at the selected location 4 Using the two screws provided fasten the adapter plate to the switch box as shown 5 Pull the wires from the switch box through the opening in the adapter plate and connect to the H46 leadwires with the solderless connectors provide...

Page 2: ...es contact on a relative humidity rise to the setpoint to start the dehumidifier On a decrease in relative humidity to the setpoint minus the differential the switch breaks contact to stop the dehumidifier Turn the knob clockwise to the setting stop to place the H46 in the On position Turn the knob counterclockwise to the setting stop to place the H46 in the Off position CHECKOUT After completing ...

Page 3: ...X O R1 W Y W1 Y1 G R H R HEAT OFF FAN AUTO ON COOL HEAT OFF COOL FIXED COOL ANTICIPATOR ADJUSTABLE HEAT ANTICIPATOR HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL FAN RELAY COIL FILTER LIGHT T87F CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION 1 M7914 Fig 4 Typical series wiring hookup of H46C with T87F Q539A combination for dehumidification and mildew control 3 95 5367 4 ...

Page 4: ...ational Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 Printed in U S A on recycled 95 5367 4 G H Rev 07 03 paper containing at least 10 www honeywell com yourhome post consumer paper fibers ...

Reviews: