background image

Europe

The CE marking on the product indicates that this device is in confor-

mity with all essential requirements of the 1999/5/EC R&TTE Direc-

tive and 2011/65/EU RoHS directive. In addition, complies to 2006/

95/EC Low Voltage Directive, when shipped with recommended 

power supply.

 

European contact:

Hand Held Products Europe B.V.

 

Nijverheidsweg 9-13

 

5627 BT Eindhoven

 

The Netherlands
Honeywell shall not be liable for use of our product with equipment 

(i.e., power supplies, personal computers, etc.) that is not CE marked and does 

not comply with the Low Voltage Directive. 

Honeywell Scanning & Mobility Product Environmental 
Information

Refer to 

www.honeywellaidc.com/environmental

 for the RoHS / REACH / 

WEEE information.

Product Agency Compliance - AP-010BT

 Class II

Brazil

Product Agency Compliance - AP-100BT

 Class I

Patents

For patent information, please refer to 

www.hsmpats.com

.

Modelo: AP-010BT

0921-11-6583

(01)07898927490089

" Este equipamento opera em caráter secundário, isto é, não tem 
direito a proteção contra interferência prejudicial, mesmo de estações 
do mesmo tipo, e não pode causar interferência a sistemas operando 
em caráter primário."

Summary of Contents for FocusBT AP-010-BT

Page 1: ...Access Point AP 010BT AP 100BT Quick Start Guide Acc Pt QS Rev D 1 15 ...

Page 2: ...l the O ring the Access Point will be rated to IP41 instead of IP54 2 Plug the interface cable into the Access Point first and then into the appropriate port on the computer The Page button blinks when the Access Point is first connected to the host 3 Turn on the computer laptop desktop USB Connection Page button ...

Page 3: ...RS232 Connection Page button RS485 Connection Page button ...

Page 4: ...e Access Point to establish a connection between the Access Point and the scanner The scanner emits a short beep and flashes the green LED to confirm a connection with the Access Point The Access Point s Page button light turns solid blue Keyboard Wedge Connection Page button ...

Page 5: ...on remains blue If you have difficulty connecting with your 4820 it may be due to Code XML software in your scanner Scan the following bar code then scan the 4820 Linking bar code These steps may resolve this connection problem Managing Connections Auto Reconnect Mode By default the Access Point is set to Auto Reconnect On so the scanner begins the relink process immediately when a con nection to ...

Page 6: ...period is one hour Pull the scanner s trigger to power the scanner back up If the scanner was linked to the Access Point when it went to sleep it will re link as long as it is in range If multiple scanners use the same Access Point it is possible to inadvertently unlink a scanner that is in sleep mode that has a dead battery or is in the process of getting a new battery To prevent this from happen...

Page 7: ...ccess Point will begin beeping 3 short and 1 long beep If you pull the trigger on a scanner that is beeping in response or press the Page button on the Access Point a second time all associ ated scanners will stop beeping LED Dimmer Scan a bar code to set the brightness of your Page button Page button LED Dimmer Off LED Dimmer Low LED Dimmer Bright ...

Page 8: ...standard defaults disconnects the scanner from the Access Point Scan the Linking bar code to re establish a connection Refer to your User s Guide at www honeywellaidc com for additional information about product defaults Additional Programming The Access Point has all the programming capability of a Cordless Charge Base Refer to Cordless System Operation information in your User s Guide at www hon...

Page 9: ...Required Safety Labels Label location for item number serial number revision information compli ance and safety information ...

Page 10: ...Ranges Operating 32 F to 122 F 0 C to 50 C Storage 40 F to 158 F 40 C to 70 C Radio Frequency 2 4 to 2 5 GHz ISM Band Frequency Hopping Bluetooth v 2 1 Range AP 010BT 33 ft 10m typical Range AP 100BT 328 ft 100m typical Data Rate Up to 1MBps Humidity 5 to 95 non condensing Mechanical Drop Operational after 50 drops from 3 28 feet 1 m to concrete Vibration 5G Peak from 22Hz to 300Hz ESD Sensitivity...

Page 11: ...o radio communications However there is no guar antee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna...

Page 12: ...device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation Conformité à la règlementation canadienne Cet appareil ISM est conforme à la norme CNR 210 du Canada Son fonctionnement est assujetti aux conditions suivantes 1 Cet appareil ne doit pas causer de brouillage préjudiciable 2 Cet appareil doit pouvoir accepter tout br...

Page 13: ...lies personal computers etc that is not CE marked and does not comply with the Low Voltage Directive Honeywell Scanning Mobility Product Environmental Information Refer to www honeywellaidc com environmental for the RoHS REACH WEEE information Product Agency Compliance AP 010BT Class II Brazil Product Agency Compliance AP 100BT Class I Patents For patent information please refer to www hsmpats com...

Page 14: ...s contained herein nor for incidental or consequential damages resulting from the fur nishing performance or use of this material This document contains proprietary information that is protected by copy right All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written con sent of HII 2010 2015 Honeywell International ...