background image

1400  

 

 
 

System Sensor 

Ionization Smoke Detector 

 

Features

 

 

• 

Unique dual unipolar sensor provides exceptional 
stability.

 

• 

Built-in tamper-resistant feature. 

• 

Built-in test switch. 

• 

Built-in visual alarm indicator. 

• 

Remote LED option. 

• 

Compatible with FCI control panels. 

• 

Field metering of detector sensitivity. 

• 

Removable insect screen and cover for field 
cleaning. 

• 

Sealed against dirt, insects, and back pressure. 

• 

Insect-resistant screening (.020"/.508mm 

 openings). 

• 

Convenient terminal strip wiring. 

GAMEWELL-FCI 

12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118 

Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 

©2006 Gamewell-FCI.   All rights reserved. 

www.gamewell-fci.com

 

 

9020-0586 Rev. B  page 1 of 2

 

Description

 

 

The System Sensor 1400 dual-chamber ionization smoke 
detector is specifically designed to meet the performance 
requirements of fire detection/alarm systems. This detec-
tor uses a state-of-the-art unipolar sensing chamber. The 
detector is designed to provide open area detection and is 
compatible with FCI fire alarm control panels. The detec-
tor operation and sensitivity can be tested in place.  

 

The detector has an LED which flashes every ten seconds 
indicating that power is being applied to the detector. The 
LED lights steadily when the detector is in alarm. A re-
mote LED annunciator is available as an optional acces-
sory. 

 

The 1400 detector includes a tamper-resistant feature 
that, when used, prevents removal of the detector without 
the use of a tool. 

 

Sensitivity testing is performed by inserting a tool into the 
recessed test switch opening.  

 

Field metering of detector sensitivity may be performed 
with the aid of a voltmeter and test kit MOD 400R. 

 

Specifications 

Nominal sensitivity  1.5%/ft. obscuration 
Operating voltage  8.5 - 35 VDC (24 VDC nominal) 
Standby current 

100 µA maximum 

Operating  
temperature 

 
32

°

 to 120

°

 F (0

°

 to 49

°

 C) 

Operating humidity  10 % - 93 % relative humidity 
Air velocity 

1,200 ft. per minute maximum 

Altitude 10,000 

feet 

Construction 

Off-white flame retardant plastic 

Diameter 

5.5 inches 

(14 cm)

 

Height 

3.12 inches 

(8.0 cm)

 

Weight 

0.7 lb 

(310 gm)

 

Note: Alarm current is limited by the control panel initiating 
device circuit. 

 

Part Number 

1400 

Ordering Information 

Description 

Ionization detector 

1400 

An ISO 9001-2000 Company 

 

Reviews: