Falcon MJ M-Bus Operating instructions

 

 

05/18 Generation 1.2 

 

Page 10 of 38 

 

Activate short tel. 

switches the mode for the M-Bus protocol on the Falcon MJ to short-form 
telegram (without monthly values)  

 

Activate long tel. 

switches  the  mode for  M-Bus  protocol  on  the  Falcon  MJ  to  long  telegram  (with 
monthly values). 

 

Read

 

updates M-Bus data on the selected tab card. 

 

Write

 

sends the current settings to the device where they will be stored. 

Notice: 

 

If  a  new  device  is  connected,  the  control  button  "Connect  to  meter"  must  first  be  pressed. 

Afterwards the tab card of the Falcon MJ will be shown. 

  

3.4  Extended configuration / alarms tab 
 

 

  

 

 

 

 

 

Summary of Contents for FALCON MJ Pulse/M-Bus

Page 1: ...ration alarms tab 10 3 4 1 Alarm Activation 11 3 4 2 Occurred alarms 11 3 4 3 Pulse settings 12 3 4 4 Manufacturer generation 13 3 4 5 Other 13 3 4 6 Security 13 4 M Bus telegrams 15 4 1 SND_UD Send User data telegram selection 15 4 1 1 Select Normal readout Short telegram 15 4 1 2 Select Enhanced readout Long telegram 16 4 2 RSP_UD data transfer on request 17 4 2 1 Short telegram for Modules with...

Page 2: ...ially stored on the configured date at 00 00 change of day to the reporting date A write protect function prevents pre set values from being modified This write protection can be improved by using a password optional Warning If this password get lost the write protection cannot be disabled anymore When the module is connected to a M Bus network the device gets its power from the M Bus The internal...

Page 3: ...ameterization software for the Falcon MJ is a 32 bit application that can be executed on an IBM compatible PC running a Windows 95 98 XP 7 10 operating system The desktop or laptop PC to be used must have a free USB interface connection This interface connection must be connected to an M Bus level converter MR003 USB MikroMaster The Falcon MJ device which I configured must have a 1 1 connection i ...

Page 4: ...estarted it will not be necessary to make this setting again Baudrate specifies the PC s interface speed It can be set to 300 2400 and 9600 baud and corresponds to the currently used M Bus baudrate The Falcon MJ module supports the baud rates 300 2400 and 9600 WITH automatic detection that means the baud rate do not need to be configured and adopts automatically to the baud rate of the M Bus netwo...

Page 5: ...Depending on the manufacturer and type of M Bus device new tab cards will then be created Manufacturer is a field that following a successful read Meter connection will display a 3 character M Bus manufacturer code upper case ASCII letters Generation displays the version of the connected M Bus module s firmware Type displays the device type of the connected device here Honeywell Elster Falcon MJ T...

Page 6: ... clipboard with the CTRL C key combination From the clipboard it is easy to paste the data into a text processing program for documenting purposes As soon as this window has reached its storage capacity no more data will be entered The displayed data must be deleted in order to allow recording to continue The following control buttons are also always visible Erase log deletes all output in the log...

Page 7: ...e changed Primary address is the M Bus address of the Falcon MJ A value between 0 and 250 can be entered into this field if the primary address needs to be changed Click on Write control button will transfer the primary address and other alterable settings on this tab card to the Falcon MJ module The addresses 253 254 and 255 are broadcast addresses 253 deselect all slaves 254 select all slaves 25...

Page 8: ...rent time into this window A click on the control arrow at the right of the date field will open a calendar for convenient selection of the date Edit Time activation of this control check box permits editing and programming of the current date and time This checkbox will automatically deactivate again after parameterization has been done successfully Volume is the current meter index in liters By ...

Page 9: ...he day and the month Read clock of PC reads the PC system s current date and time and enters this data into the Current time field Due date cnt is the stored meter counter index for the Due date This field cannot be edited read only Due date is the last reporting date i e date when the meter index was stored the last time in the format DD MM YY This field cannot be edited read only Next due date i...

Page 10: ...long tel switches the mode for M Bus protocol on the Falcon MJ to long telegram with monthly values Read updates M Bus data on the selected tab card Write sends the current settings to the device where they will be stored Notice If a new device is connected the control button Connect to meter must first be pressed Afterwards the tab card of the Falcon MJ will be shown 3 4 Extended configuration al...

Page 11: ...ire which alarm just occurs Backward flow alarm is activated when more than 3 litres continuous backflow are measured Magn Manipulation alarm is activated when a manipulation attempt with an external magnet is detected Removal alarm Is activated when the module is removed from the meter Battery alarm Is activated when the remaining lifetime of the battery is lower than app 13 months 3 4 2 Occurred...

Page 12: ...e width For the pulse output an open drain is used The polarity must be observed The pulse output is compatible to the most systems that were used with a Reed switch before Pulse incr Specifies the pulse output resolution in litres per pulses All full values between 1 and 1000 liters are possible Dosing applications For special dosing applications you can enter the value 9999 This value will give ...

Page 13: ...odule should show app 3 6 V 3 4 6 Security The security settings enable or disables the write protection setting With activated write protection values like the meter index or due date values cannot be changed anymore In addition there is the possibility to protect the write protection with an additional password The password can be max 32 signs long Use of Password to activate write protection En...

Page 14: ... 14 of 38 The following control buttons are also always visible Read updates M Bus data on the selected tab card Even fields which cannot be modified will be updated Exit Close the extended configuration alarm tab Reset alarms All stored alarms will be cleared to 0 ...

Page 15: ...te 68h 5 C Field Send user data 53h 6 A Field Secondary addressing mode FDh 7 CI Field Application Select long Header 53h Transport Layer TPL 8 Ident Nr Ident No LSB BCD 78h 9 Ident Nr Ident No BCD 56h 10 Ident Nr Ident No BCD 12345678 34h 11 Ident Nr Ident No MSB BCD 12h 12 Manufr Manufacturer code 92h 13 Manufr Manufacturer code 15h 14 Version Version or Generation number B1h 15 Device type Devi...

Page 16: ... 53h 6 A Field Secondary addressing mode FDh 7 CI Field Application Select long Header 53h Transport Layer TPL 8 Ident Nr Ident No LSB BCD 78h 9 Ident Nr Ident No BCD 56h 10 Ident Nr Ident No BCD 12345678 34h 11 Ident Nr Ident No MSB BCD 12h 12 Manufr Manufacturer code 92h 13 Manufr Manufacturer code 15h 14 Version Version or Generation number B1h 15 Device type Device type Medium Water 07h 16 Acc...

Page 17: ...9 Ident Nr Ident No BCD 56h 10 Ident Nr Ident No BCD 12345678 34h 11 Ident Nr Ident No MSB BCD 12h 12 Manufr Manufacturer code 92h 13 Manufr Manufacturer code 15h 14 Version Version or Generation number xxh 15 Device type Device type Medium Water 07h 16 Access No Access number of Meter 2Ah 17 Status M Bus state 00h 18 Config Field no Encryption 00h 19 Config Field no Encryption 00h 20 DR1 DIF 8 di...

Page 18: ...R6 Value 00h 52 DR6 Value 0 003 m 00h 53 DR6 Value MSB 00h 54 DR7 DIF Date Max Value Type G 12h 55 DR7 VIF Date 6Ch 56 DR7 Value xxh 57 DR7 Value xxh 58 DR8 DIF 16 bit Int Max Value 12h 59 DR8 VIF Flow Rate l h 3Bh 60 DR8 Value xxh 61 DR8 Value xxh 62 DR9 DIF 16 Bit Int 02h 63 DR9 VIF Flow Rate l h 3Bh 64 DR9 Value xxh 65 DR9 Value xxh 66 DR10 DIF Backflow Alarm Date Type F C4h 67 DR10 DIFE Storag...

Page 19: ... Secondary addressing mode FDh 7 CI Field 72h long header 72h Transport Layer TPL 8 Ident Nr Ident No LSB BCD 78h 9 Ident Nr Ident No BCD 56h 10 Ident Nr Ident No BCD 12345678 34h 11 Ident Nr Ident No MSB BCD 12h 12 Manufr Manufacturer code 92h 13 Manufr Manufacturer code 15h 14 Version Version or Generation number xxh 15 Device type Device type Medium Water 07h 16 Access No Access number of Meter...

Page 20: ...47 DR6 DIF 8 digit BCD 0Ch 48 DR6 VIF Volume l Extension 93h 49 DR6 VIFE backward flow 3Ch 50 DR6 Value LSB 03h 51 DR6 Value 00h 52 DR6 Value 0 003 m 00h 53 DR6 Value MSB 00h 54 DR7 DIF Date Max Value Type G 12h 55 DR7 VIF Date 6Ch 56 DR7 Value xxh 57 DR7 Value xxh 58 DR8 DIF 16 bit Int Max Value 12h 59 DR8 VIF Flow Rate l h 3Bh 60 DR8 Value xxh 61 DR8 Value xxh 62 DR9 DIF 16 Bit Int 02h 63 DR9 VI...

Page 21: ...DIFE Storagenumber 20 0Ah 92 DR14 VIF Date Type G 6Ch 93 DR14 Value LSB xxh 94 DR14 Value MSB xxh 95 DR15 DIF 8 digit BCD Ext 8Ch 96 DR15 DIFE Storagenumber 8 04h 97 DR15 VIF Volume l 13h 98 DR15 Value LSB xxh 99 DR15 Value xxh 100 DR15 Value xxh 101 DR15 Value MSB xxh 102 DR16 DIF 8 digit BCD Ext CCh 103 DR16 DIFE Storagenumber 9 04h 104 DR16 VIF Volume l 13h 105 DR16 Value LSB xxh 106 DR16 Value...

Page 22: ...enumber 14 07h 139 DR21 VIF Volume l 13h 140 DR21 Value LSB xxh 141 DR21 Value xxh 142 DR21 Value xxh 143 DR21 Value MSB xxh 144 DR22 DIF 8 digit BCD Ext CCh 145 DR22 DIFE Storagenumber 15 07h 146 DR22 VIF Volume l 13h 147 DR22 Value LSB xxh 148 DR22 Value xxh 149 DR22 Value xxh 150 DR22 Value MSB xxh 151 DR23 DIF 8 digit BCD Ext 8Ch 152 DR23 DIFE Storagenumber 16 08h 153 DR23 VIF Volume l 13h 154...

Page 23: ...DR27 Value xxh 184 DR27 Value xxh 185 DR27 Value MSB xxh 186 DR28 DIF Manufacturer specific Frame 1Fh 187 DR28 PBIT xxh 188 Checksum xxh DLL 189 Stop Stop byte 16h Frame 2 RSP UD M Bus OMS M Bus frame Meter example Layer Byte No Field Name Content Bytes hex 1 Start Start byte 68h Data Link Layer DLL 2 L Field Length of data xx bytes xxh 3 L Field Length of data xx bytes xxh 4 Start Start byte 68h ...

Page 24: ...31 DIF 16 bit Int max Val Extension D2h 31 DR31 DIFE Storagenumber 29 0Eh 32 DR31 VIF Date Type G 6Ch 33 DR31 Value xxh 34 DR31 Value xxh 35 DR32 DIF 16 bit Int max Val Extension D2h 36 DR32 DIFE Storagenumber 29 0Eh 37 DR32 VIF Volume flow l h 3Bh 38 DR32 Value xxh 39 DR32 Value xxh 40 DR33 DIF 16 bit Int max Val Extension 92h 41 DR33 DIFE Storagenumber 30 0Fh 42 DR33 VIF Date Type G 6Ch 43 DR33 ...

Page 25: ... xxh 78 DR40 DIF 16 bit Int max Val Extension D2h 79 DR40 DIFE Extension 80h 80 DR40 DIFE Storagenumber 33 01h 81 DR40 VIF Volume flow l h 3Bh 82 DR40 Value xxh 83 DR40 Value xxh 84 DR41 DIF 16 bit Int max Val Extension 92h 85 DR41 DIFE Extension 81h 86 DR41 DIFE Storagenumber 34 01h 87 DR41 VIF Date Type G 6Ch 88 DR41 Value xxh 89 DR41 Value xxh 90 DR42 DIF 16 bit Int max Val Extension 92h 91 DR4...

Page 26: ...47 VIF Date Type G 6Ch 124 DR47 Value xxh 125 DR47 Value xxh 126 DR48 DIF 16 bit Int max Val Extension D2h 127 DR48 DIFE Extension 82h 128 DR48 DIFE Storagenumber 37 01h 129 DR48 VIF Volume flow l h 3Bh 130 DR48 Value xxh 131 DR48 Value xxh 132 DR49 DIF 16 bit Int max Val Extension 92h 133 DR49 DIFE Extension 83h 134 DR49 DIFE Storagenumber 38 01h 135 DR49 VIF Date Type G 6Ch 136 DR49 Value xxh 13...

Page 27: ... xxh 156 DR53 DIF 16 bit Int max Val Extension 92h 157 DR53 DIFE Extension 80h 158 DR53 DIFE Storagenumber 40 01h 159 DR53 VIF Date Type G 6Ch 160 DR53 Value xxh 161 DR53 Value xxh 162 DR54 DIF 16 bit Int max Val Extension 92h 163 DR54 DIFE Extension 80h 164 DR54 DIFE Storagenumber 40 01h 165 DR54 VIF Volume flow l h 3Bh 166 DR54 Value xxh 167 DR54 Value xxh 168 Checksum xxh DLL 169 Stop Stop byte...

Page 28: ... No MSB BCD 12h 12 Manufr Manufacturer code 92h 13 Manufr Manufacturer code 15h 14 Version Version or Generation number xxh 15 Device type Device type Medium Water 07h 16 Access No Access number of Meter 2Ah 17 Status M Bus state 00h 18 Config Field no Encryption 00h 19 Config Field no Encryption 00h 20 DR1 DIF 8 digit BCD 0Ch Application Layer APL 21 DR1 VIF Volume l 13h 22 DR1 Value LSB 73h 23 D...

Page 29: ...xh 58 DR8 DIF 32 bit Int Max Value 14h 59 DR8 VIF Flow Rate l h 3Bh 60 DR8 Value xxh 61 DR8 Value xxh 62 DR8 Value xxh 63 DR8 Value xxh 64 DR9 DIF 32 Bit Int 04h 65 DR9 VIF Flow Rate l h 3Bh 66 DR9 Value xxh 67 DR9 Value xxh 68 DR9 Value xxh 69 DR9 Value xxh 70 DR10 DIF Backflow Alarm Date Type F C4h 71 DR10 DIFE Storage No 7 03h 72 DR10 VIF Date Time 6Dh 73 DR10 Value LSB xxh 74 DR10 Value xxh 75...

Page 30: ... 9 Ident Nr Ident No BCD 56h 10 Ident Nr Ident No BCD 12345678 34h 11 Ident Nr Ident No MSB BCD 12h 12 Manufr Manufacturer code 92h 13 Manufr Manufacturer code 15h 14 Version Version or Generation number xxh 15 Device type Device type Medium Water 07h 16 Access No Access number of Meter 2Ah 17 Status M Bus state 00h 18 Config Field no Encryption 00h 19 Config Field no Encryption 00h 20 DR1 DIF 8 d...

Page 31: ...m 00h 53 DR6 Value MSB 00h 54 DR7 DIF Date Max Value Type G 12h 55 DR7 VIF Date 6Ch 56 DR7 Value xxh 57 DR7 Value xxh 58 DR8 DIF 32 bit Int Max Value 14h 59 DR8 VIF Flow Rate l h 3Bh 60 DR8 Value xxh 61 DR8 Value xxh 62 DR8 Value xxh 63 DR8 Value xxh 64 DR9 DIF 32 Bit Int 04h 65 DR9 VIF Flow Rate l h 3Bh 66 DR9 Value xxh 67 DR9 Value xxh 68 DR9 Value xxh 69 DR9 Value xxh 70 DR10 DIF Backflow Alarm...

Page 32: ...t 8Ch 100 DR15 DIFE Storagenumber 8 04h 101 DR15 VIF Volume l 13h 102 DR15 Value LSB xxh 103 DR15 Value xxh 104 DR15 Value xxh 105 DR15 Value MSB xxh 106 DR16 DIF 8 digit BCD Ext CCh 107 DR16 DIFE Storagenumber 9 04h 108 DR16 VIF Volume l 13h 109 DR16 Value LSB xxh 110 DR16 Value xxh 111 DR16 Value xxh 112 DR16 Value MSB xxh 113 DR17 DIF 8 digit BCD Ext 8Ch 114 DR17 DIFE Storagenumber 10 05h 115 D...

Page 33: ...mber 15 07h 150 DR22 VIF Volume l 13h 151 DR22 Value LSB xxh 152 DR22 Value xxh 153 DR22 Value xxh 154 DR22 Value MSB xxh 155 DR23 DIF 8 digit BCD Ext 8Ch 156 DR23 DIFE Storagenumber 16 08h 157 DR23 VIF Volume l 13h 158 DR23 Value LSB xxh 159 DR23 Value xxh 160 DR23 Value xxh 161 DR23 Value MSB xxh 162 DR24 DIF 8 digit BCD Ext CCh 163 DR24 DIFE Storagenumber 17 08h 164 DR24 VIF Volume l 13h 165 DR...

Page 34: ...tart Start byte 68h Data Link Layer DLL 2 L Field Length of data xx bytes xxh 3 L Field Length of data xx bytes xxh 4 Start Start byte 68h 5 C Field Respond user data 08h 6 A Field Secondary addressing mode FDh 7 CI Field 72h long header 72h Transport Layer TPL 8 Ident Nr Ident No LSB BCD 78h 9 Ident Nr Ident No BCD 56h 10 Ident Nr Ident No BCD 12345678 34h 11 Ident Nr Ident No MSB BCD 12h 12 Manu...

Page 35: ... Volume flow l h 3Bh 40 DR32 Value xxh 41 DR32 Value xxh 42 DR32 Value xxh 43 DR32 Value xxh 44 DR33 DIF 16 bit Int max Val Extension 92h 45 DR33 DIFE Storagenumber 30 0Fh 46 DR33 VIF Date Type G 6Ch 47 DR33 Value xxh 48 DR33 Value xxh 49 DR34 DIF 32 bit Int max Val Extension 94h 50 DR34 DIFE Storagenumber 30 0Fh 51 DR34 VIF Volume flow l h 3Bh 52 DR34 Value xxh 53 DR34 Value xxh 54 DR34 Value xxh...

Page 36: ...nt max Val Extension D4h 89 DR40 DIFE Extension 80h 90 DR40 DIFE Storagenumber 33 01h 91 DR40 VIF Volume flow l h 3Bh 92 DR40 Value xxh 93 DR40 Value xxh 94 DR40 Value xxh 95 DR40 Value xxh 96 DR41 DIF 16 bit Int max Val Extension 92h 97 DR41 DIFE Extension 81h 98 DR41 DIFE Storagenumber 34 01h 99 DR41 VIF Date Type G 6Ch 100 DR41 Value xxh 101 DR41 Value xxh 102 DR42 DIF 32 bit Int max Val Extens...

Page 37: ...36 DR46 Value xxh 137 DR46 Value xxh 138 DR47 DIF 16 bit Int max Val Extension D2h 139 DR47 DIFE Extension 82h 140 DR47 DIFE Storagenumber 37 01h 141 DR47 VIF Date Type G 6Ch 142 DR47 Value xxh 143 DR47 Value xxh 144 DR48 DIF 32 bit Int max Val Extension D4h 145 DR48 DIFE Extension 82h 146 DR48 DIFE Storagenumber 37 01h 147 DR48 VIF Volume flow l h 3Bh 148 DR48 Value xxh 149 DR48 Value xxh 150 DR4...

Page 38: ...IF Volume flow l h 3Bh 176 DR52 Value xxh 177 DR52 Value xxh 178 DR52 Value xxh 179 DR52 Value xxh 180 DR53 DIF 16 bit Int max Val Extension 92h 181 DR53 DIFE Extension 80h 182 DR53 DIFE Storagenumber 40 01h 183 DR53 VIF Date Type G 6Ch 184 DR53 Value xxh 185 DR53 Value xxh 186 DR54 DIF 32 bit Int max Val Extension 94h 187 DR54 DIFE Extension 80h 188 DR54 DIFE Storagenumber 40 01h 189 DR54 VIF Vol...

Reviews: