background image

F116 (SERIES 16000) SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER

68-0200-2  Revised 10-07

16

LIMITED TWO-YEAR WARRANTY

Air-Pure Systems

16873 Fish Point Rd. SE
Prior Lake, MN  55372-1714
Phone: (800) 998-1919
Fax: (800) 221-3248

Air-Pure Systems warrants its air cleaner products to be free from defects in workmanship or materials under normal use and service, for a
period of two (2) years from the date of purchase by the originial end-user. If at anytime during the warranty period the product is defective
or malfunctions, Air-Pure Systems, through the distributor or dealer, from which the product was purchased, or through an authorized
warranty repair station, shall at Air-Pure Systems option, replace or repair the defective product or component.

This warranty does not cover removal or installation costs. This warranty shall not apply if it is shown that the defect or malfunction was
caused by damage which occurred during handling or shipment, improper electrical connections, improper use of the product or abuse.

Air-Pure Systems sole responsibility shall be to repair or replace the product within the terms stated above. 

AIR-PURE SYSTEMS SHALL

NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER
FAILURE OF THIS PRODUCT. 

(Some states do not allow the exclusion or limitation or incidental or consequential damages, so this

limitation may not apply to you.)

. THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND AIR-PURE SYSTEMS EXPRESSLY

DISCLAIMS ALL OTHER WARRANTIES, WHETHER WRITTEN OR ORAL, IMPLIED OR STATUTORY, INCLUDING BUT NOT
LIMITED TO ANY WARRANTIES OR MERCHANTABILITY, WORKMANSHIP, OR FITNESS FOR A PARTICULAR USE.

This warranty gives you specific legal rights and you may have other rights which vary from state to state.

How to make a warranty claim or have questions answered:

Should you have a warranty claim or questions about the warranty policy, contact the distributor or dealer from which you purchased the
product or the authorized warranty repair stations nearest your location.

NOTE:  Do not return any products or parts to the factory without a factory issued "Return Warranty Good Label" issued by Air-Pure
Systems.

In the event you or other persons, have any questions concerning the use and care of this product of this warranty please call or write the
factory.

Air-Pure Systems

16873 Fish Point Rd. SE
Prior Lake, MN 55372-1714
Phone: (800) 998-1919
Fax : (800) 221-3248

Summary of Contents for F116

Page 1: ... application Three speed direct drive forward curve blower motor circulates up to 2500 cfm 72 m3 min for large areas Negative and positive pressure rooms can be created with the air cleaner Charcoal permanganate and zeolite CPZ disposable modules can be used for odor control Two stage and three stage air cleaners are compatible with a wide range of applications 120 Vac 60 Hz and 208 220 Vac 50 60 ...

Page 2: ...at 120V or 7A at 220V Refer to Table 2 for maximum starting loads l e d o M e g a t l o V g n i r e t l i F s e g a t S s n i a t n o C s n o i t a c i l p p A d e t s e g g u S 1 2 0 1 A 6 1 1 F z H 0 6 c a V 0 2 1 A 4 1 S H P 1 o w T d n a r e t l i f e r p 1 r e t l i f A P E H 1 s m o o r n a e l c l a i r t s u d n i s d r a w n o i t a l o s i l a c i d e M s e t a l u c i t r a p c i x o t ...

Page 3: ... l i f A P E H 9 4 0 0 6 1 G W 3 1 8 6 9 4 1 4 0 0 6 1 7 4 0 1 A 6 1 1 F 8 4 0 2 A 6 1 1 F 5 9 r e t l i f P O D 2 5 0 0 8 1 G W 1 1 9 5 0 3 1 r e t l i f t o p s t s u d E A R H S A 5 9 8 5 0 0 0 2 G W 0 1 9 4 8 0 1 r e t l i f t o p s t s u d E A R H S A 5 6 8 5 0 0 0 2 G W 5 7 0 9 4 8 0 1 s e l u d o m t n e b r o s Z P C 9 4 0 0 6 1 G W 5 0 5 6 3 4 1 2 1 0 6 1 0 2 1 1 A 6 1 1 F 1 2 1 2 A 6 1 1...

Page 4: ...3 x 0 1 6 x 0 1 6 0 0 8 1 t a n o r c i m 3 0 t a 5 9 m 2 5 m f c 3 n i m e m a r f l a t e m n I t o p s t s u d E A R H S A 2 1 x 4 2 x 4 2 5 0 3 x 0 1 6 x 0 1 6 t a t o p s t s u d E A R H S A 5 9 m 8 5 m f c 0 0 0 2 3 n i m e m a r f l a t e m n I 2 1 x 4 2 x 4 2 5 0 3 x 0 1 6 x 0 1 6 t a t o p s t s u d E A R H S A 5 6 m 8 5 m f c 0 0 0 2 3 n i m e m a r f l a t e m n I e l u d o M t n e b r ...

Page 5: ...D INSERT HOLE FOR HANGING INSTALLATION HEPA D O P OR ASHRAE FILTER ELECTROSTATIC PRECIPITATOR COLLECTING CELLS PREFILTER SORBENT MODULES M10810 TOP 7 8 22 FLANGE 12 1 8 308 13 1 2 343 10 254 7 178 FRONT VIEW Fig 1 Approximate dimensions of two stage filtering model in in mm Please Note Electrostatic Precipitator Collecting Cells are no longer available ...

Page 6: ...PRECIPITATOR COLLECTING CELLS PLANNING THE INSTALLATION Application and Operation The F116 series 16000 self contained ductable commercial air cleaner is designed for use in smoking areas hospitals in plant office areas or plant satellite offices printing shops areas that do brazing soldering or gluing and commercial cooking areas Because the air cleaner provides its own air circulation it can be ...

Page 7: ...NG Remove packing materials from Blower Wheel prior to installation or initial power on 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After insta...

Page 8: ... Fig 4 Positioning air cleaners at the far end of the restaurant smoking section to draw the smoke away from the nonsmoking section Fig 5 Positioning air cleaners to create a negative pressure in polluted spaces and creating a positive pressure in nonpolluted areas Use this positioning in in plant offices and hospitals M7782 ...

Page 9: ... air cleaner to create a negative pressure booth that contains a contamination generating process Fig 8 Positioning air cleaner to remove pollutants from a conveyor feed process such as screen printing TOP VIEW CURTAIN CONVEYOR DRYER HOOD INPUT CURTAIN OUTPUT DRYER INPUT SIDEVIEW M10797 AIR CLEANER AIR CLEANER Fig 9 Positioning air cleaner to create positive pressure for a plant satellite office P...

Page 10: ... WHERE THERE IS HEAVY OIL SMOKE COOKING HEAVY WELDING OR HEAVY CUTTING M10800 AIR CLEANER DO NOT INSTALL WHERE THERE IS HEAVY OIL SMOKE COOKING HEAVY WELDING OR HEAVY CUTTING M10801 AIR CLEANER Fig 11 Connecting air cleaner directly to a canopy hood with a minimum air entrance velocity of 120 fpm Fig 12 Positioning air cleaner to recirculate existing exhaust system air which contains light to medi...

Page 11: ...re connection when attaching the air cleaner outlet to the blower discharge flange See Fig 16 The outlet connection can be used with a Y branch distribution box or manifold as required Fig 16 Square to round connection attached to the air cleaner outlet Wire All wiring must comply with applicable codes and ordinances The power source must agree with the air cleaner electrical rating 120 Vac 60 Hz ...

Page 12: ...urn off power to the air cleaner Stand on a stable platform when working with the air cleaner Maintenance 1 Remove the air cleaner cover and set it aside 2 Remove the prefilter and primary filters 3 Locate the blower motor and apply 3 to 4 drops of light weight oil to the shaft bearings NOTE Shaft bearings need oil once a year or every 3 or 4 months when the air cleaner operates 24 hours a day 4 U...

Page 13: ... e r n o i t c e t o r p l a m r e h t r o t o m t o h r o f k c e h C r o t o m e c a l p e R l e e h w r e w o l b m o r f g n i k c a p g n i p p i h s e v o m e R n o i t a r b i V y c n e u q e r F h g i H r o e c n a l a b d n a e v o m e r d e c n a l a b s i l e e h w r e w o l b t a h t k c e h C l e e h w e c a l p e r n o i t a r b i V y c n e u q e r F w o L e c u d e r e r u s s e r p...

Page 14: ...9 1 0 0 0 2 3 4 2 0 0 6 8 5 9 r e t l i f t o p s t s u d E A R H S A 1 6 9 1 0 0 0 2 3 5 2 0 0 6 8 5 6 r e t l i f t o p s t s u d E A R H S A 1 7 9 1 0 0 0 2 3 6 2 0 0 6 8 2 s e r i u q e r e l u d o m t n e b r o s Z P C 1 1 0 0 8 7 0 4 0 0 2 3 A N 2 s e r i u q e r e l u d o m t n e b r o s y l n o l a o c r a h C 1 2 0 0 8 7 0 4 0 0 2 3 A N 2 s e r i u q e r e l u d o m t n e b r o s y l n o ...

Page 15: ...G CELL 1 PREFILTER 2 SORBENT MODULES M10812 HEPA D O P OR ASHRAE FILTERS 1 1 TWO STAGE MODELS WILL HAVE ONLY ONE PRIMARY FILTER AREA 2 2 Fig 18 Exploded view of F116 series 16000 self contained ductable commercial air cleaner components Please Note Electrostatic Precipitator Collecting Cells are no longer available ...

Page 16: ...E FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation or incidental or consequential damages so this limitation may not apply to you THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND AIR PURE SYSTE...