PROCESS INFORMATION DISPLAYS
6510020335
144
Fields
Description
Recipe List
Displays all the recipes that have already been
established
Recipe Start / Recipe End
1.
When you press the “
Recipe Start
” button then
any information that the scanner collects about
your process is used in the statistical and MIS
reports. You press the “
Recipe Start
” button
when actual product is being produced.
2.
When you press the “
Recipe End
” button, then
although the scanner is still collecting data about
your product, this information is not included in
the statistical information.
6.9.1
Selecting the Next Recipe
To select the next recipe, follow the below instructions:
1.
From the Recipe Change window, select the name of the recipe you want to use . The
selected recipe is highlighted.
2.
Click the Retrieve Recipe button. This loads the selected recipe in the Next position.
All the recipe parameters, as set for this recipe appears in the Next Target column.
3.
You have now set up the next recipe to run. However, the system is still using the
data in the Current Target column. You can select the next recipe to run at any time
without affecting the system.
6.9.2
Loading the Current Recipe
To load a recipe, follow the below instructions:
1.
Select the recipe to load. See section Selecting the Next Recipe.
2.
Make any necessary edits to the next recipe’s parameters.
3.
If you are collecting data for statistical purposes and MIS reports, press the Recipe
End button to stop collecting the data and to generate reports for the product that
was being measured.
4.
When the new material to be measured reaches the calendar, press the Load Recipe
button. This causes all the information (including any parameters that you edited)
about this new material to be loaded into the QCS system.
5.
The Next Position column transfers into Current Position column.
Summary of Contents for Experion MX
Page 1: ...Experion MX RELEASE 702 1 Operators Guide 6510020335 Rev 02 May 2019 ...
Page 7: ...6510020335 7 8 NOTICES 168 ...
Page 20: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 20 Fig 15 Cable End Voltage Zones ...
Page 21: ...SCANNER SAFETY AND LOCAL CONTROLS 6510020335 21 Fig 16 Distant End Voltage Zones ...
Page 124: ...PROCESS INFORMATION DISPLAYS 6510020335 124 Fig 105 Profile Display ...
Page 159: ...PROCESS INFORMATION DISPLAYS 6510020335 159 Fig 148 Precision Platform 4000 01 Scanner ...
Page 160: ...PROCESS INFORMATION DISPLAYS 6510020335 160 Fig 149 Precision Platform 4000 20 21 Scanner ...