Honeywell Enraf FlexLine RMA805 Quick Start Installation Manual Download Page 4

RMA805 Enraf FlexLine Remote Indicator Quick Start Guide 

 

 
 

MSG 

CODE  AGENCY  TYPE OF PROTECTION 

Electrical 

Parameters  Ambient Temperature 

cCSAus 

Explosion proof: 

Class I, Division 1, Groups A, B, C, 

D;T6..T4 

 

Dust Ignition Proof: 

Class II, III, Division 1, Groups E, 

F, G; T4 

Class I Zone 1 Ex db IIC T4 Gb 

Ex db IIC T4 Gb 

 

Zone 21 Ex tb IIIC T 95°C Db 

Ex tb IIIC T 95°C Db 

Note 1 

T6: -50°C to +65°C 

T4 T5: -50°C to 85°C 

Intrinsically Safe: 

CSA 14.2689056 

Class I, II, III, Division 1, Groups 

A, B, C, D, E, F, G; T4 

Ex ia IIC T4 Ga 

Note 2 

-50°C to 70°C 

Non-Incendive 

Class I, Division 2, Groups A, B, 

C, D; T4 

Class I Zone 2 Ex nA IIC T4 Gc 

Ex nA IIC T4 Gc 

Note 1 

-50°C to 85°C

 

Enclosure: 4X/ IP66/ IP67  

ALL 

ALL

 

Standards: CSA C22.2 No. 0: 2015; CSA C22.2 No. 30: 2016; CSA C22.2 No. 

94-M91; CSA C22.2 No. 25: 2017; CSA C22.2 No. 61010-1: 2017; CSA-

C22.2No.157: 2016; C22.2 No. 213: 2017; C22.2 No. CSA 60079-0:2015; 

C22.2 No. 60079-1: 2016; C22.2 No. 60079-11: 2014; C22.2 No. 60079-15: 

2016; C22.2 No. 60079-31: 2015; 

ANSI/ ISA12.12.01-2017; ANSI/ ISA 61010-1: 2016; ANSI/ UL 60079-0: 2013; 

ANSI/ UL 60079-1: 2015; ANSI/ UL 60079-11: 2014; ANSI/ UL 60079-15: 

2013; ANSI/ UL 60079-31: 2015;   

FM 3600: 2011; FM 3615: 2006; FM Class 3616: 2011; ANSI/ UL 913:  2015; 

UL 916: 2015; ANSI/ UL 12.27.01: 2017; ANSI/UL 50E: 2015 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

MSG 

CODE  AGENCY  TYPE OF PROTECTION 

Electrical 

Parameter

Ambient Temperature 

 

 

NEPSI 

 

Flame-proof:  

Ex d IIC Ga/Gb T4  

Ex tb IIIC Db T 85°C 

Note 1 

 

-50°C to 85°C  

 

Intrinsically Safe:  

Ex ia IIC Ga T4  

Note 2 

-50°C to 70°C  

 

Nonincendive:  

Ex nA IIC Gc T4  

Note 1 

 

-50°C to 85°C 

 

  

Enclosure: IP 66/67  

    

All 

All 

 

Notes 

 

1. 

Operating Parameters:  

Voltage= 12 to 42 V  

Current= 25 mA  

 

2. Intrinsically Safe Entity Parameters 

 

For details see Control Drawing, 50089981. 

 

 

 

 

 

 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Enraf FlexLine RMA805

Page 1: ...red to a Horizontal or Vertical Pipe 2 Figure 3 Two Position FF Terminal Block 2 Documentation To access complete documentation including language variants scan the QR code below using your smart phone device or QR code scanner Go to the APP store for your free Smartphone QR scanner Or you can follow the URL to access the online Tank Storage Documentation The Documentation page will contain direct...

Page 2: ...ipped wire should be in the insulated portion of the ferrule The ferrule can be also be used on the solid core wire Figure 3 Two Position FF Terminal Block Electrical Wiring The Remote Indicator shall be connected to the Loop and Loop terminals of the FlexLine Gauge Typically these are terminals 24 and 25 See the installation manual of the FlexLine Gauge for more information It is possible that ot...

Page 3: ...s see table 6 Display Setup LCD Contrast For details see table 5 Device Setup HART Setup Parameters For details see table 4 Information Display Comm Module For details see table 3 Return Return to the Level 1 menu LCD Contrast Return Set Contrast 0 9 Default 5 Adjust the LCD contrast level Press to edit or to select number and to enter Return Return to the Level 1 menu Return Parameters HART Addre...

Page 4: ...6 CSA C22 2 No 94 M91 CSA C22 2 No 25 2017 CSA C22 2 No 61010 1 2017 CSA C22 2No 157 2016 C22 2 No 213 2017 C22 2 No CSA 60079 0 2015 C22 2 No 60079 1 2016 C22 2 No 60079 11 2014 C22 2 No 60079 15 2016 C22 2 No 60079 31 2015 ANSI ISA12 12 01 2017 ANSI ISA 61010 1 2016 ANSI UL 60079 0 2013 ANSI UL 60079 1 2015 ANSI UL 60079 11 2014 ANSI UL 60079 15 2013 ANSI UL 60079 31 2015 FM 3600 2011 FM 3615 20...

Page 5: ...IZED WARNING OPEN CIRCUIT BEFORE REMOVING COVER All Protective Measures WARNING FOR CONNECTION IN AMBIENTS ABOVE 60 C USE WIRE RATED 105 C A 3 Conditions of Use for Ex Equipment Hazardous Location Equipment or Schedule of Limitations a Consult the manufacturer for dimensional information on the flameproof joints for repair b Painted surface of the RMA 800 series may store electrostatic charge and ...

Page 6: ...6 RMA805 Enraf FlexLine Remote Indicator Quick Start Guide A 4 Control Drawing ...

Page 7: ...Sales Email enraf us honeywell com or TAC hfs tac support honeywell com Web Knowledge Base search engine http bit ly 2N5Vldi WARRANTY REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship Contact your local sales office for warranty information If warranted goods are returned to Honeywell during the period of coverage Honeywell will repair o...

Reviews: