![Honeywell Enraf 1010 CB Programming Manual Download Page 65](http://html.mh-extra.com/html/honeywell/enraf-1010-cb/enraf-1010-cb_programming-manual_151423065.webp)
Metering Lines (4)
6 - 11
Model 1010 Application Pack CB
Part No.: 4418024 - Rev. 1
Programming Manual
Meter n
Manual DP
If the Pm is regulated, enter the manual value for Dp.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Available only if commodity type is NGL and LPG(E) and
Regulated PM is selected as YES.
Enter a value in the following range:
Meter n
Calculate FP
Selects whether to calculate the Compressibility Factor or not.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Available only if commodity type is NGL and LPG(E) and
Regulated PM is selected as NO.
Select one of the following options:
Yes
No*
Meter n
Manual FP
This prompt allows entry of the manual value for the compressibility
factor (F)
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode
and
•
Commodity type is NGL and LPG(E) and Regulated PM is
selected as YES.
Or
•
Regulated PM is selected as NO and calculate FP is selected as
NO.
Table 6-5: MPMS Equilibrium and Compressibility Calculations
Units
Base
Temp
Entry Ranges
Equilibrium Pressure (Pe)
Manual Entry of Dp
Psig
60 °F
0 to 2200.0
0 to 2200.0
kPa
15 °C
0 to 15168.47
0 to 15168.47
20 °C