PRODUCT SPECIFICATIONS
Range:
15 m x 18 m (50' x 60')
Alarm relay (DT-7450):
Energized Form A
125 mA, 25 VDC, 20 Ohm series resistor
Alarm relay (DT-7450C):
Energized Form C
125 mA, 25 VDC, 20 Ohm series resistor
Tamper switch:
(NC) 50 mA, 24 VDC
Power requirements:
7.5 - 16 VDC (for UL 8.0 - 16 VDC)
DT-7450 -- 25 mA typical, 30 mA maximum, 12 VDC
DT-7450C -- 30 mA typical, 35 mA maximum, 12 VDC
AC Ripple: 3 V peak-to-peak at nominal 12 VDC
Microwave frequencies:
24.125 GHz
PIR white light immunity:
6,500 Lux typical
Fluorescent light filter:
50 Hz or 60 Hz selectable
RFI immunity:
30 V/m,10 MHz - 1000 MHz
Operating temperature:
14
o
F to +131
o
F (-10
o
C to +55
o
C)
5 - 95% relative humidity (non-condensing)
Temperature compensation:
Advanced Dual Slope
Self-test intervals:
Microwave Supervision
PIR self-test
Temp. Comp.
PIR fields-of-view:
Standard Wide Angle Lens
22 long range edges
12 intermediate edges
6 lower edges
4 Look-down edges
Dimensions:
11.9 cm H x 7.1 cm W x 4.2 cm D
(4.685" H x 2.795" W x 1.654" D)
Sensitivity:
Low (Pulse count 2) 3 - 4 steps
High (Pulse count 1) 2 - 3 steps
Accessories:
Optional Lens Kit -- Curtain Lens Kit (P/N DT7000-LRLK)
SMB-10 Swivel Mount Bracket (P/N 0-000-110-01)
SMB-10C Swivel Mount Ceiling Bracket (P/N 0-000-111-01)
SMB-10T Swivel Mount Bracket w/ Tamper (P/N 0-000-155-01)
Approvals/listings:
FCC
IC
cULus
© 2001 Honeywell
International Inc. • Honeywell, IntelliSense and DUAL TEC are registered trademarks of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved.
5-051-640-00 Rev E
LED INDICATORS
DIP SWITCH SETTINGS (SW1)
Factory default settings are shown in grey.
DETECTION PATTERNS
DT
-7450/7450C DU
AL TEC
®
Motion Sensor Product Information
40' 50'
30'
20'
10'
0
0
15 m
40'
12 m
12 m
12 m
40'
30'
9 m
9 m
9 m
30'
20'
6 m
6 m
6 m
20'
10'
3 m
3 m
3 m
10'
0
0
floor
long range
intermediate
lower
down
Zones
50'
40'
30'
20'
10'
0
2.3 m (7'6")
3 m
6 m
9 m
12 m 15 m
DT-7450/7450C Side View
Wide Angle Lens
TROUBLE SHOOTING
Problem:
Red LED is flashing rapidly.
Explanation:
The sensor is in one of three conditions:
Microwave supervision failure: The sensor continues operating
using PIR as the only detection method. When detection occurs
on the PIR channel, the alarm relay will latch open until the
Microwave trouble is removed.
PIR self-test failure: Alarm relay does not actuate.
Temperature compensation failure: When alarm occurs, the
alarm relay will latch open until the trouble is cleared.
Solution:
Power down the sensor or enter the zone finder mode
which will perform self-test. If the trouble does not clear, replace
the sensor.
LED
Red
Yellow
Green
Normal
ON
Alarm
ON
Microwave
ON
PIR
Power Up
Slow
Blink
OFF
OFF
Trouble
Fast
Blink
OFF
OFF
Zone Finder
OFF
ON
Microwave
ON
PIR
OPERATION MODE
DT-7450/7450C Top View
Wall Mounted Wide Angle Lens with Typical Alarm Pattern
FCC Notice
: This equipment has been tested and found to comply with the limits for
a field disturbance sensor pursuant to Part 15 of the FCC Rules. The user is
cautioned that changes or modifications not expressly approved by Honeywell could
void the user’s authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
S
witch
1
2
3
OFF
Low Sensitivity
(Pulse Count 2)
LED Disabled
60 Hz Fluorescent Filter
ON
High Sensitivity
(Pulse Count 1)
LED Enabled
50 Hz Fluorescent Filter