- 2 -
T
C
V
-
V
+
T
NC
5
12V
Zone
#
Zone
COM
Zone
#
Zone
COM
Tamper
30 mA
25 VDC
Power
17 mA
9-15 VDC
(UL: 9.5-15 VDC)
Alarm
30 mA
25 VDC
6
4
2 1
5
3
22-20 AWG
(0.31-0.52mm
2
)
2
2
1
T
C
V
-
V
+
T
NC
6
4
2 1
5
3
Panel / Panneau / Panel / Controle
Sensor / Détecteur / Sensor / Sensor
30 sec
30
0
45
20
10
6
MW
SENSITIVITY
MAX
MIN
*
ON
PI
LED
1/2 sec.
hold 4x
< 4’ (1.2m)
Walk Test Reset
1. Apply power to the sensor. Initialization is complete when the LED stops
flashing slowly (about 30 seconds).
2. Turn the microwave sensitivity counterclockwise to reduce the microwave
range (minimum = 16.4’ / 5m) and close the sensor.
3. Walk through the detection area and observe the LED.
4. Adjust the microwave range as necessary to meet installation requirements.
Walk test mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal
operation mode. For an additional 10 minute walk test, enable walk test mode again with the flashlight feature (see Walk
Test Reset above).
Note
: During power up and walk test modes the LED is active regardless of the LED Enable/Disable DIP switch setting.
7
PLAN VIEW
ALL ZONES
A
B
C
D
7.5ft
(2.3m)
0ft
(0m)
7ft
(2m)
13ft
(4m)
20ft
(6m)
27ft
(8m)
33ft
(10m)
40ft
(12m)
13ft
(4m)
0ft
(0m)
7ft
(2m)
13ft
(4m)
20ft
(6m)
27ft
(8m)
33ft
(10m)
40ft
(12m)
7ft
(2m)
0ft
(0m)
7ft
(2m)
13ft
(4m)
20ft
(6m)
20ft
(6m)
27ft
(8m)
33ft
(10m)
27ft
(8m)
33ft
(10m)
Top View
Vue de dessus
Vista Desde Arriba
Vista Superior
Side View
Vue de coté
Vista Lateral
Vista Lateral
LED
Power Up
Walk Test
Normal
Fault
Red
Slow
Blink
ON
Alarm
ON
Alarm
Fast
Blink
Yellow
OFF
ON
Microwave
ON
Microwave
OFF
Green
OFF
ON
PIR
ON
PIR
OFF
Zones / Zones / Zonas / Zonas
A
2
Look-down / Basses / Vista Zona 0 /
Vigilância inferior
B
18
Lower / Courtes / Cercana/ Mais baixas
C
46
Intermediate / Intermédiaires / Intermedia /
Intermédias
D
36
Long / Longues / Largo Alcance / Longo
alcance