DR4500A Classic Series Circular Chart Recorder With or Without Control Product Manual
13
April 2017
2.2 Model Number Interpretation
Model number
The model number interpretation is shown in Figure 2-1. Write the model number into the spaces provided
and compare it to the model number interpretation. This information will also be useful when you wire
your recorder. The example on the next page will help you to decode the model.
Figure 2-1 Model number interpretation
Input Actuation (Note 1)
D R
4 5 A
0
0
0
1
3
=
=
=
None
T/C, RTD, Radiamatic ,
mV, 0–5V, 4–20mA
0–10 Vdc
External Output
0 0
1 0
1 1
4 0
4 4
5 0
6 0
6 6
= None
= 1 Control Output
= 2 Control Outputs
= 1 Control w/SP Programming
= 2 Controls w/SP Programming
= Pulse Output
= 1 Control Output with FM Approval
= 2 Control Outputs with FM Approval
Table 1
Table 2
Table 3
Table 4
Table 5
Key Number
Hardware Options
0 - - - - -
1 - - - - -
E - - - - -
F - - - - -
5 - - - - -
6 - - - - -
Software Options
0
A
B
E
F
H
K
L
M
= None
= Totalization , Input 1
= Math Only
= Totalization , Inputs 1 & 2
= Fo Sterilization Calculation
= Totalization , Inputs 1, 2, 3, & 4
= Totalization , Input 1 + Math
= Totalization , Input 1 and 2 + Math
= Totalization , Input 1, 2, 3, 4 + Math
–
–
–
–
–
–
Table 6
Key Number
T
R
W
H
P
S
=
=
=
=
=
=
Standard Recorder
Relay expansion Recorder
Flow Recorder
HTST
Pasteurization Recorder - Flow
Safety Thermal Limit Recorder
NOTE 1:
Every DR4500A recorder has all the available inputactuations stored in its nonvolatile memory
and can accept up to 4 inputs which must be specified sequentially in 1–4 entries in Table 1.
Therefore, you can easily change the input actuation in the field by re-wiring input connections,
changing the input jumper position, and reconfiguring the input type, as applicable.
Gray door / Glass window
Gray door / Acrylic window
Gray door / Glass window and keypad
Gray door / Acrylic window and keypad
Blue door / Glass window
Blue door / Acrylic window
External Interface
0 – –
1 – –
3 – –
4 – –
– 0 –
– 1 –
– – 0
– – 1
– – 2
– – 3
– – 4
= None
= Auxiliary 4-20 mA Output
= RS485 Modbus RTU**
= RS485 Modbus RTU** plus Auxiliary Output
= Standard Pen
= Abrasion Resistant Pen
= None
= 2 Alarm Outputs/2 Digital Inputs
= 4 Alarm Outputs/2 Digital Inputs
= 6 Alarm Outputs/2 Digital Inputs
= 1 Alarm/1 Timer/2 Digital Inputs **
**Only available with key number DR45AT, AR, AW
=
=
=
=
=
=
L - - - - -
9 - - - - -
Black door / Glass window
Black door / Acrylic window
=
=
P - - - - -
R - - - - -
S - - - - -
NEMA4X door / Glass window
NEMA4X door / Acrylic window
NEMA4X HTST door
=
=
=
- 0 - - - -
- A - - - -
- K - - - -
- - 0 - - -
- - L - - -
- - M - - -
- - N - - -
- - - 0 - -
- - - K - -
- - - L - -
- - - M - -
- - - N - -
- - - P - -
Standard door latch
Keyed latch
Door lock with key
No illumination
Configuration lockout / Chart plate seal
Configuration Lockout / Chart plate seal / Illumination
Chart illumination
No approvals
CE Mark
CE Mark + UL + CSA certification
CE Mark + FM approval
CE Mark + UL + FM / CSA certification
UL l CSA certification
=
=
=
=
=
=
=
=
=
=
=
=
=
- - - R - -
FM approved - Class 1, Div. 2, Groups A, B, C, D
=
- - - U - -
- - - - 0 -
- - - - T -
- - - - B -
- - - - C -
- - - - D -
- - - - E -
- - - - - 0
- - - - - 1
UL l CSA certifi FM approval
No I.D. Tag
Customer I.D. Tag (30 characters maximum)
Certificate of Conformance (F3391)
Custom Calibration / Test Report (F3399)
Certificate of Confo I.D. Tag
Customer Calib I.D. Tag
None
Product Configuration
=
=
=
=
=
=
=
=
=
1
= 1 Pen Recorder
2
= 2 Pen Recorder