69-1055—1

4

T8524C,D MULTISTAGE MICROELECTRONIC THERMOSTATS

A combination of key presses are required to use the
Installer Setup feature.

To enter the Installer Setup mode, press and hold the
Information

   i   

key with the increase 

 and decrease

 keys until the first number is displayed. All display

segments appear for approximately three seconds
before the number is displayed. See Fig. 9 and 10.

To advance to the next Installer Setup number, press
the Information

   i   

key.

To change a setting, use the increase 

 or de-

crease 

 key.

To exit the Installer Setup, press and hold the
Information

   i   

key until the display returns to normal

(approximately three seconds). The display scrolls the
numbers backwards to get to the normal display. The
Installer Setup is automatically exited if no key
presses are made for five minutes.

IMPORTANT

Only configurable numbers are shown on the
device. Example: If the thermostat does not have
a system key, Installer Setup Number 12 will not
be displayed. Review Table 2 factory-settings
and mark any desired changes in the Actual
Setting column. When Installer Setup in com-
plete, review the settings to confirm that they
match the system.

Fig. 8. T8524D system and fan keys location.

NOTE:

Always press the system and fan keys with your
fingertip or similar blunt tool. Sharp instruments
like a pen or pencil point can damage the
keyboard.

Temperature Settings

The default setpoint for heat is 70

°

F (21

°

C) and for cool is

78

°

F (25.5

°

C). Press the increase 

 or decrease 

 key to

change the present setting. To change between heat and
cool, press the Information

   i   

key until the setting to be

changed appears.

INSTALLER SETUP

NOTE:

For most applications, the thermostat factory-
settings do not need to be changed. Review the
factory-settings in Table 2 and if no changes are
necessary, go to the Installer System Test
section.

The Installer Setup is used to customize the thermostat to
specific systems. Installer Setup Numbers are listed in
Table 2. The table includes all the configuration options
available.

Fig. 7. T8524C system and fan switches location.

M10147

i

Press to select
heating or cooling
equipment.

  

Em. Ht.-Emergency heating
Heat— Heating equipment
Off — No equipment
Cool—Cooling equipment
Auto—Thermostat

automatically selects
heating and cooling
equipment.

Press to select
heating or cooling
equipment.

  

On

Fan runs continuously

Auto—Fan runs when

heating or cooling
equipment operates

System

System

System

Fan

Fan

Fan

1

1

CHECK LIGHT ON SELECT MODELS

M10105

MODE NUMBER DISPLAY 
(COLUMN 2 OF TABLE 2)

FACTORY SETTING OR
OTHER CHOICE DISPLAY
(COLUMN 3 OR 5 OF TABLE 2)

Em HeatOffCool Auto Only

Heat Cool

OnAuto

System

Fan

Room

Outdoor

Em Ht Temporary Setting

Wait

%Humid

Aux Ht

Remote

Repl

Batt

M4844

M10146

i

HEAT      OFF      COOL

ON    AUTO

HEAT      OFF      COOL

ON    AUTO

SYSTEM

Selection for heating or cooling
equipment operation.

Heat - Heating equipment
Off - No equipment
Cool - Cooling equipment

FAN

On - Fan runs continuously
Auto  - Fan runs when

heating or cooling
equipment operates

Fig. 9. Display of all the segments of the LCD.

Fig. 10. Display of Installer Setup mode and setting.

CAUTION

Electric heat systems must be configured to 01 in
Installer Setup 02 to prevent equipment damage
caused by the system running without the fan.

Summary of Contents for DMULTISTAGE T8524C

Page 1: ... your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check out the product operation CAUTION Disconnect power supply to prevent electrical shock or equipment damage Location Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average temperature See Fig 1 Do not install th...

Page 2: ...ews into the holes 6 Tighten mounting screws WIRING All wiring must comply with local electrical codes and ordinances Refer to Fig 3 for typical hookups A letter code is located near each terminal for identification CAUTION Disconnect power before wiring to prevent electrical shock or equipment damage 1 Loosen the terminal screws on the wallplate and connect the system wires See Fig 4 IMPORTANT Us...

Page 3: ...A B PRESS LOWER EDGE OF CASE TO LATCH A ENGAGE TABS AT TOP OF THERMOSTAT AND WALLPLATE M6801 DISPLAY PRESENT SETTINGS AND SCROLL THROUGH INSTALLER SETUP MODES INFORMATION KEY i DECREASE TEMPERATURE SETTING INCREASE TEMPERATURE SETTING Using Thermostat Keys The thermostat keys are used to set temperature display present setting configure Installer Setup check System Test display outdoor temperature...

Page 4: ...ting To change between heat and cool press the Information i key until the setting to be changed appears INSTALLER SETUP NOTE For most applications the thermostat factory settings do not need to be changed Review the factory settings in Table 2 and if no changes are necessary go to the Installer System Test section The Installer Setup is used to customize the thermostat to specific systems Install...

Page 5: ...geover Not used 13 Degree temperature display 14 00 Temperature is displayed in F 01 Temperature is displayed in C Not used 15 thru 18 Extended fan operation in heatinga b 19 00 No extended fan operation after the call for heat ends 01 Fan operation is extended 90 seconds after the call for heat ends Extended fan operation in coolinga 20 00 No extended fan operation after the call for cool ends 01...

Page 6: ...nAuto System Fan Room Outdoor Em Ht Temporary Setting Wait Humid Aux Ht Remote Repl Batt M4844 M6792 TEST MODE NUMBER a Available on select models b T8524D is 48 F 9 C IMPORTANT Review the settings to confirm that they match the system INSTALLER SYSTEM TEST Use the Installer System Test to check the thermostat configurations and operation Refer to Table 3 for a list of the available system tests T...

Page 7: ...n T8524C 31 Stage one cool and system fan come on 32 Stage two cool comes on Stage one cool and system fan remain on 31 Stage two cool turns off 30 Stage one cool and system fan turn off Fan Equipment System test T8524D only i 40 Change from cooling to fan equipment system test 41 Fan comes on 40 Fan turns off Key or Switch Operation System test IMPORTANT Test Numbers will only be displayed when t...

Page 8: ...ill not come on Thermostat is not being powered Check that C terminal is connected to the system transformer Check for 24 Vac between C and R or RH terminals If missing 24 Vac check if the circuit breaker is tripped reset the circuit breaker check if the system fuse is blown replace the fuse check if the power switch on the HVAC equipment is in the Off position set to the On position check wiring ...

Page 9: ...pment replace any broken wires and tighten any loose connections If 24 Vac is present proceed with troubleshooting Thermostat minimum off time is activated Wait up to five minutes for the system to respond Enter Installer Setup mode number 33 Reconfigure minimum off time if required System selection is not set to Cool Set system selection to Cool Cooling setpoint is above room temperature Check co...

Page 10: ...69 1055 1 10 T8524C D MULTISTAGE MICROELECTRONIC THERMOSTATS ...

Page 11: ...69 1055 1 11 T8524C D MULTISTAGE MICROELECTRONIC THERMOSTATS ...

Page 12: ...ATS Home and Building Control Honeywell Limited Honeywell Limitée 155 Gordon Baker Road North York Ontario M2H 3N7 Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 69 1055 1 J H Rev 6 97 www honeywell com yourhome ...

Reviews: