Honeywell DirectConnect AMX300 Installation Instructions Manual Download Page 5

AMX300 DIRECTCONNECT™ MIXING VALVE KITS

5

62-3113—01

thermostrip, ensure the hot water tank recovers from any 

aquastat adjustment and the temperature of the hot water in 

the heater has stabilized.

Measure the mixed water supply temperature by opening 

the hot water tap at the nearest faucet supplied by the 

AMX300 mixing valve. A minimum flow rate of 1 to 1.5 gpm 

(4 to 6 L/min) is recommended for accurate temperature 

readings on the thermostrip (see Fig. 8). Allow the hot water 

to run until a steady temperature reading is displayed on 

the thermostrip.

Fig. 8. Flow vs. pressure drop.

WARNING

Increasing water temperature increases the risk of 

scald injury. Scalding may occur within 5 seconds 

at a setting of 140°F (60°C). Water temperature 

over 125°F (52°C) can cause burns or death from 

scalds. Children, the disabled, and the elderly are 

at highest risks of being scalded. Please feel the 

water before bathing or showering.

.

The mixed water supply temperature may require adjustment. 

The mixing valve kit is set at approximately 120°F when the 

arrow on the hand wheel and the arrow on the valve body are 

aligned.

1. To Increase mixed water supply temperature:

 Push 

in and rotate the hand wheel counter-clockwise until the 

desired set point is reached as indicated on the ther-

mostrip reading (see Fig. 9). Ensure the hand wheel 

snaps back to a locked position once desired set point is 

reached.

2. To Decrease mixed water supply temperature:

 Push 

in and rotate the hand wheel clockwise until the desired 

set point is reached as indicated on the thermostrip 

reading (see Fig. 9). Ensure the hand wheel snaps back 

to a locked position once desired set point is reached.

Fig. 9. Thermostrip.

MAINTENANCE

Honeywell recommends that the AMX300 mixing valve kit be 

checked annually to ensure proper operation. In areas with 

adverse water conditions, such as extremely hard water, more 

frequent intervals are recommended.

Hard water conditions may result in scale deposits causing 

binding of internal parts in extreme cases. Scale build-up 

occurs more quickly with high water hardness and higher 

temperature of the water stored in the tank.

Cleaning the internal parts will usually restore the valve 

operating conditions. In some cases, it may be necessary to 

replace the thermostatic element assembly (See Fig. 10). A 

Thermostatic Element Replacement Kit, AM-1-025RP, is 

available through Honeywell distributors.

To remove scale from the internal surfaces of the AMX300 

mixing valve, or to replace the thermostatic element, it is not 

necessary to remove the valve from the piping. Simply 

perform the following steps:

1.

Shut off cold water supply to the water heater

2.

Open a hot water faucet to drain hot water from the sys-

tem piping

3.

Follow directions in the MAINTENANCE section of 

“AMX300 Series DirectConnect™ Mixing Valve Installa-

tion Instructions”, Honeywell literature # 62-3112 (sup-

plied with the AMX300 mixing valve kit)

4.

Open the cold water supply shut-off valve until hot water 

flows from the hot water faucet that was opened in step 

2 above.

5.

When a steady stream of water flows from the faucet, 

close the faucet

6.

Check for leaks on the AMX300 mixing valve and 

tighten components as required

7.

Restart the water heater, following the water heater 

manufacturer's directions, and wait until it reaches set-

point and the temperature in the tank has stabilized

8.

Test the temperature at the mixed water outlet (as 

described in the TEMPERATURE ADJUSTMENT sec-

tion above) and adjust hand wheel position as neces-

sary to achieve desired temperature.

Table 1. Time/Temperature Relationship in Scalds.

Water Temperature

Time to scald (approximate)

155 °F (68 °C)

About 1 second

150 °F (66 °C)

About 1-1/2 seconds

145 °F (63 °C)

Less than 3 seconds

140 °F (60 °C)

Less than 5 seconds

135 °F (57 °C)

About 10 seconds

130 °F (54 °C)

About 30 seconds

125 °F (52 °C)

1-1/2 – 2 minutes

120 °F (49 °C)

More than 5 minutes

 

FLOW VERSUS PRESSURE DROP

PRESSURE

DROP

(PSI)

FLOW (GPM)

50

40

30

20

0

4

12

16

20

M29789

MIXED

TEMPERATURE

OF 140°F

60

10

0

2

8

6

10

14

18

MIXED

TEMPERATURE

OF 120°F

MIXED

TEMPERATURE

OF 95°F

Thermostrip

Accuracy expires

after MMMYYYY

11

0

43

11

2

44

11

4

46

11

6

47

11

8

48

120

49

122

50

124

51

126

52

128

53

130

54

132

55

134

56

136

57

138

58

140

60

ºF ºc

11

6

47

11

8

48

120

49

122

50

124

51

M29700

Summary of Contents for DirectConnect AMX300

Page 1: ...us injury GETTING STARTED CAUTION For the homeowner s comfort safety and convenience it is recommended this mixing valve kit be installed and serviced by a plumbing professional These instructions provide detailed instructions for installation and maintenance of the mixing valve kit You must read these instructions carefully and completely to ensure proper installation Safety Precautions WARNING W...

Page 2: ...ternal components causing it to not regulate the mixed water temperature properly If using sweat fittings to connect the mixing valve kit to the plumbing system DO NOT apply heat to the mixing valve after it is connected to the water heater Sweat the copper tubing of the plumbing system to the threaded adapter before connecting the adapter to the mixing valve 4 The valve MUST NOT be allowed to fre...

Page 3: ...ixtures refer to literature 62 3112 AMX300 Series DirectConnect Mixing Valve Installation Instructions Refer to Fig 2 and 3 for descriptions and locations of the inlet and outlet ports on the mixing valve and cold water tee Fig 2 Mixing valve connections Fig 3 Cold water tee connections WARNING Do not return recirculation loop to any other location other than R inlet of the mixing device If recirc...

Page 4: ...the AMX300 mix ing valve and cold water tee as shown in Fig 7 Tighten flare connectors until leak tight At this time the mixing valve kit should be leak tight Fig 7 Install flexible connector Continue installation of potable water system as indicated in the installation and operation instruction manual supplied with the water heater Once potable water system has been completely installed and all c...

Page 5: ...re quickly with high water hardness and higher temperature of the water stored in the tank Cleaning the internal parts will usually restore the valve operating conditions In some cases it may be necessary to replace the thermostatic element assembly See Fig 10 A Thermostatic Element Replacement Kit AM 1 025RP is available through Honeywell distributors To remove scale from the internal surfaces of...

Page 6: ...xing valve kit due to seasonal temperature variations in the cold water supply Fig 10 Exploded view of AMX300 Mixing Valve M31029 VALVE BODY PLUG SPRING AQUAMIX 1 THERMAL ELEMENT PLASTIC SPOOL HANDWHEEL FLAT SHOULDER SCREW SPRING SPINDLE ASSY O RING DIFFUSER CONTENTS OF THERMOSTATIC ELEMENT REPLACEMENT KIT AM 1 025RP ...

Page 7: ...AMX300 DIRECTCONNECT MIXING VALVE KITS 7 62 3113 01 Replacement Parts Rebuild kit for AMX300 mixing valve AM 1 025RP Thermostrips in packs of 10 TS205 064 ...

Page 8: ... Honeywell International Inc 1985 Douglas Drive North Golden Valley MN 55422 Honeywell Limited Honeywell Limitée 35 Dynamic Drive Toronto Ontario M1V 4Z9 customer honeywell com U S Registered Trademark 2010 Honeywell International Inc 62 3113 01 M S 01 10 Printed in U S A ...

Reviews: