background image

END-OF-SEASON CARE AND STORAGE

• Follow weekly CLEANING instructions at end of humidification season or when 
humidifier will not be used for at least one week or more. Remove and throw away
the filter

;

do not store with a used filter.

• Let humidifier dry completely before storing. Do not store with water inside the
Reservoir Base or water tank.

• Pack the unit in its original carton and store in a cool, dry location.

• Remember to install a new filter and clean the humidifier at the start of the next
humidification season.

Models HCM-1000 Series are rated 0.45 Amps at 120V, 60 Hz.
Models HCM-2000 Series are rated 0.6 Amps at 120V, 60 Hz.

WARNING: IF YOU EXPERIENCE A PROBLEM WITH YOUR HUMIDIFIER’S POWER
UNIT, PLEASE SEE THE WARRANTY FOR INSTRUCTIONS. PLEASE DO NOT
ATTEMPT TO OPEN OR REPAIR THE HUMIDIFIER YOURSELF. DOING SO MAY VOID
THE WARRANTY AND COULD CAUSE DAMAGE OR PERSONAL INJURY. IF THE
PROBLEM STILL PERSISTS, PLEASE CALL:

HONEYWELL INC. 
CUSTOMER SERVICE DEPARTMENT

TOLL FREE:  1-800-332-1110

Mail questions or 
comments to:

HONEYWELL INC.

Consumer Relations Dept.
250 Turnpike Road
Southborough, MA  
01772
U.S.A.

Please be sure to specify model number.

ELECTRICAL RATINGS

Summary of Contents for DH835

Page 1: ...OWNER S MANUAL Moisture Control Off High Med Lo w POWER REFILL DESIRED HUMIDITY COOL MOISTURE HUMIDIFIER Models HCM 1000 2000 Series Model HCM 2000 ...

Page 2: ...than a 120V AC polarized outlet If you are unable to insert the plug fully into the outlet try reversing the plug If the plug should still fail to fit contact an electrician to replace the obsolete outlet DO NOT defeat the safety purpose of the polarized plug 6 A loose fit between the AC outlet and plug may cause overheating of the plug Have a qualified electrician replace the outlet 7 The humidif...

Page 3: ...he proper moisture level in your home or office with your Honeywell Cool Moisture Humidifier may also Replace needed moisture in furniture Keep indoor plants moist and healthy Eliminate cracking and dryness in wood furniture and fixtures Minimize static electricity H O W D O E S I T W O R K Dry air is pulled through the Cool Moisture system and a quiet fan disperses invisi ble moisture balanced ai...

Page 4: ...difier Turn the Water Tank upside down so that the fill cap is facing up Fill the Water Tank with COOL tap water Fig 3 Distilled water is not necessary as the water is filtered by the Cool Moisture filter DO NOT USE HOT WATER Replace the fill cap CAUTION WHEN CARRYING THE FILLED WATER TANK PLEASE USE THE HANDLE AND PLACE YOUR OTHER HAND UNDER THE TANK FOR ADDITIONAL SUPPORT Turn Water Tank right s...

Page 5: ... THE HUMIDIFIER FAN WILL NOT START OR RESTART WHEN YOU SELECT A FAN SPEED THE HUMIDISTAT MAY BE SET TOO LOW MOVING THE HUMIDITY LEVEL KNOB TO A HIGHER SETTING THE LARGEST BLACK DOT BEFORE THE SIGN SHOULD RESTART THE FAN When a comfortable humidity level is reached lower the Moisture Control Humidistat setting slowly by turning the knob clockwise until the fan stops Fig 4 The DESIRED HUMIDITY light...

Page 6: ...ER OR DAMAGE THE HUMIDIFIER THEREBY HINDERING THE HUMIDIFIER S EFFECTIVENESS DO NOT USE SOAP DETERGENTS OR ABRASIVE CLEANSERS Cleaning involves two steps SCALE REMOVAL and DISINFECTING Be sure to per form these in the proper order to avoid harmful chemical interactions First turn off and unplug the humidifier Then remove the Water Tank by grasping the handle and pulling straight up Fig 6 Lift the ...

Page 7: ...Reservoir Base A F T E R D I S I N F E C T I N G Clean all surfaces of the power unit with a dry soft cloth WARNING DO NOT USE WATER TO CLEAN THE POWER UNIT THIS MAY DAMAGE THE HUMIDIFIER OR CAUSE ELECTRIC SHOCK If you have hard water you may need to clean or change the filter more often If the filter is dirty rinse it under cold tap water and turn the filter upside down before repositioning in th...

Page 8: ...rt of the next humidification season Models HCM 1000 Series are rated 0 45 Amps at 120V 60 Hz Models HCM 2000 Series are rated 0 6 Amps at 120V 60 Hz WARNING IF YOU EXPERIENCE A PROBLEM WITH YOUR HUMIDIFIER S POWER UNIT PLEASE SEE THE WARRANTY FOR INSTRUCTIONS PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HUMIDIFIER YOURSELF DOING SO MAY VOID THE WARRANTY AND COULD CAUSE DAMAGE OR PERSONAL INJURY IF...

Page 9: ...tions or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This warranty applies only to the original purchaser of this product from the original date of purchase B At its option Honeywell will repair or replace this product if it is found defective in material or workmanship Defective produ...

Reviews: