8.3
PARAMETERS WHICH APPLY TO A SPECIFIC PROGRAM
AS A WHOLE
Parameter
Message
Display
Function
Available Settings (Lower Main Display)
Cycle Count
Defines the number of
times a program will be
repeated.
0 - 9999
Program will repeat
the set number of
times
Program will repeat
indefinitely
Guaranteed
Soak
Selects operation of
Guaranteed Soak facility
(relative to setpoint) - see
Figure 8-1.
No Guaranteed Soak
Above setpoint only
Below setpoint only
Above and below
setpoint
Guaranteed
Soak Band
Defines the width of the
Guaranteed Soak Band
-see Figure 8-1.
Numerical value (0 to-span)
Guaranteed
Soak On
Defines whether the
Guaranteed Soak facility
is used on ramps only, on
soaks only or on both
ramps and soaks.
On ramps and soaks
On soaks only
On ramps only
Pre-x60
Defines whether the
timebase for the program
is pre-selected to be
hours/minutes or
minutes/seconds (NOTE:
This parameter setting is
over-ruled by the
external “x60” input).
No pre-selection
Minutes/seconds
Hours/minutes
Timer (RTC
only)
Selects/de-selects timer
control of program.
Timer control selected
Timer control not
selected
Start Hour
(Timer On)
Defines start time for
program.
24.00 (0.00) to 23.59
Start Day
(Timer On)
Defines day(s) for
program to run.
Sun
,
Mon
,
tue
,
Wed
,
thu
,
Fri
,
Sat
,
5 dY
(Mon - Fri),
6 dY
(Mon - Sat) or
ALL
(all 7 days of the week)
This se quence may be viewed/ed ited for any pro gram by chang ing the Pro gram
Num ber with the
PROG
key, then step ping through the pa rame ters with the
SET
UP
key.
8-3
Program Number = 1 to 8
Segment Number = Blank
Summary of Contents for dcp100t
Page 1: ...EN1I 6240 ...
Page 2: ......
Page 10: ...2 3 DISPLAYS 2 3 Figure 2 2 Front Panel Displays ...
Page 22: ...8 4 Figure 8 1 Guaranteed Soak Operation ...
Page 33: ...9 7 Figure 9 1 Proportional Band and Deadband Overlap ...
Page 34: ...9 8 Figure 9 2 Alarm Operation ...
Page 41: ......
Page 42: ......