INTRODUCTION 

The DC300 Series are single use filtering facepieces with a National Institute for Occupational Safety and 
Health (NIOSH) classification of N95. 

 

DC300N95 

Filtering Facepiece Respirator without nose clip 

 

DC300N95V 

Filtering Facepiece Respirator without nose clip, includes exhalation valve 

 

DC301N95 

Filtering Facepiece Respirator with nose clip 

This Instruction Manual refers only to the use of these filtering facepieces. These filtering facepieces should 
only be used by individuals who have completely read and understand the instructions contained within this 
Instruction Manual. For any questions please contact Honeywell Respiratory Technical Services at (800) 873-
5242 (press 2)  
 

 

WARNINGS 

 

This respirator helps protect against certain contaminants. It may not eliminate the risk of 
contracting disease or infection. Misuse may result in sickness or death. Materials which may come 

into contact with the wearer’s skin could cause allergic reactions to s

usceptible individuals.  

 

This respirator has not been evaluated to determine whether it is safe or effective for the prevention of 
COVID-19 or other communicable illnesses.

 

 

NOT for use in any 

surgical setting or where significant exposure to liquid, bodily or hazardous fluids, 

may be expected. 

 

NOT

 for use in presence of high intensity heat source or flammable gas. 

 

NOT

 evaluated for use in a clinical setting. 

 

NOT

 evaluated for antimicrobial or antiviral protection. 

 

 

WARNINGS 

 

Improper Use of Your Respirator Can Be Harmful or Deadly! 

For Your Safety, Read and Follow These Directives. 

If You Do Not Understand Them

Ask Your Supervisor!   

 

1.

 

Failure to follow all instructions and limitations concerning the use of the respirator and/or 
failure to wear the respirator for the whole duration of exposure to contaminants can seriously 

reduce the performance characteristics of the respirator and lead to illness, injury or death.  

2.

 

Never use this respirator: 

a)

 

To perform or observe sand-blasting/abrasive-blasting; 

b)

 

To perform or observe spray painting; 

c)

 

To fight fires; 

d)

 

For protection from asbestos; 

e)

 

In oxygen deficient atmospheres (any atmosphere having less than 19.5% oxygen by 
volume at sea level); 

f)

 

In atmospheres where the concentrations of toxic contaminants are unknown, or are 
Immediately Dangerous to Life or Health (IDLH). An IDLH atmosphere is any 
atmosphere which has a concentration of any toxic, corrosive or asphyxiant substance 

that poses an immediate threat to life, which would cause irreversible debilitating 
effects on health, or which would interfere with the ability to escape from a dangerous 
atmosphere; 

 

 

Summary of Contents for DC300 Series

Page 1: ...nual Honeywell International Inc 10 Thurber Boulevard Smithfield RI 02917 USA 800 873 5242 US Canada 001 800 446 1495 México 54 911 3578 8295 Argentina 54 911 3578 8295 y 55 11 3309 1021 Latinoamérica 11 3309 1000 Brasil 50165841 001 Rev A ...

Page 2: ...icant exposure to liquid bodily or hazardous fluids may be expected NOT for use in presence of high intensity heat source or flammable gas NOT evaluated for use in a clinical setting NOT evaluated for antimicrobial or antiviral protection WARNINGS Improper Use of Your Respirator Can Be Harmful or Deadly For Your Safety Read and Follow These Directives If You Do Not Understand Them Ask Your Supervi...

Page 3: ...ions or modifications including painting or affixing labels can reduce protection and expose the user to the risk of illness injury or death CAUTIONS 1 Before occupational use of this respirator a written respiratory protection program must be implemented meeting all the local government requirements 2 In the United States employers must comply with OSHA 29 CFR 1910 134 which includes medical eval...

Page 4: ...negative pressure should be felt inside the respirator 4 If you detect air leaking in readjust the respirator by a applying additional pressure on the nose clip to assure a secure seal on the nose b adjusting the position of the respirator on your face and or c adjusting the position of the head straps WARNING If you cannot achieve satisfactory fit do NOT enter the contaminated area See your Super...

Reviews: