CT54 THERMOSTAT

69-1696EF

2

MERCURY NOTICE

If this thermostat is replacing a control that 
contains mercury in a sealed tube, do not place 
the old thermostat in the trash. Contact your local 
waste management authority for instructions 
regarding recycling and proper disposal of this 
control or of an old control containing mercury in 
a sealed tube.

STEP 3. CONNECT WIRES TO NEW 

THERMOSTAT

IMPORTANT

All wiring must comply with local building codes 
and ordinances. If you are unsure about house-
hold wiring procedures, please call your local 
heating/cooling contractor.   

1.

Remove the cover on the new thermostat. To 
remove the cover, insert your thumb into the inden-
tation on the bottom and pull the cover away from 
the thermostat (see Fig. 3). 

2.

Loosen the R and W terminal screws on the back 
of the new thermostat (see Fig. 4). 

3.

Remove the two wires from the pencil and attach 
one wire to the R terminal and the other wire to the 
W terminal (see Fig. 4 and 5).

4.

Plug the hole in the wall with insulation to prevent a 
warm or cool draft from affecting the operation of 
the thermostat.

Fig. 3. Remove cover on new thermostat.

Fig. 4. R and W terminals on new thermostat.

Fig. 5. Wraparound and straight wiring connections.

STEP 4. MOUNT NEW 

THERMOSTAT TO WALL

1.

Position the thermostat on the wall.

 

Place a level 

on top of the thermostat and use a pencil to mark 
the two mounting holes on the wall (see Fig. 6).

2.

Move the thermostat to the side and drill the 
mounting

 

holes in the wall

 

using a 1/16 in. drill bit 

at the locations you marked. 

3.

Position the thermostat over the drilled holes and 
loosely insert the mounting screws into the drilled 
holes. Check the leveling of the thermostat and 
tighten the mounting screws. Do not over tighten.

Fig. 6. Mount new thermostat to wall.

M19646

BOTTOM OF
THERMOSTAT

COVER

M19647

R

W

M19648

FOR WRAPAROUND 
INSERTION STRIP 
7/16 IN. (11 MM)

FOR STRAIGHT
INSERTION 
STRIP 
5/16 IN. (8 MM)

.18

.2

.25

.3

.9

.7

.5

.4

L

O NGER

LEVEL

D

A

TE CODE

MODEL NO

.

M19649

NOTE: MOVE TEMPERATURE 

LEVER IF IT BLOCKS 
MOUNTING HOLE

MOUNTING
HOLE

MOUNTING
HOLE

Summary of Contents for CT54

Page 1: ...that may fasten the cover to the thermostat 3 Locate the heat anticipator scale and the heat anticipator lever on the old thermostat see Fig 1 Fig 1 Heat anticipator on old thermostat example 4 Record the number that the heat anticipator lever points to on the heat anticipator scale NOTE If you cannot find the heat anticipator setting on your thermostat you can use a standard setting for your type...

Page 2: ... the W terminal see Fig 4 and 5 4 Plug the hole in the wall with insulation to prevent a warm or cool draft from affecting the operation of the thermostat Fig 3 Remove cover on new thermostat Fig 4 R and W terminals on new thermostat Fig 5 Wraparound and straight wiring connections STEP 4 MOUNT NEW THERMOSTAT TO WALL 1 Position the thermostat on the wall Place a level on top of the thermostat and ...

Page 3: ...ditional information go to www honeywell com your home or call Honeywell Customer Care at 1 800 468 1502 Before calling please have the following information available Thermostat model number and date code refer to Fig 6 for the location of the model number and date code Type of heating system for example gas or oil warm air hot water Heating System Heat Anticipator Setting Amps Hot Water 8 High E...

Page 4: ...S A on recycled paper containing at least 10 post consumer paper fibers Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Page 5: ... toute vis qui retiendrait le couvercle au thermostat 3 Repérer l échelle de la résistance anticipatrice de chaleur et le doigt de réglage de la résistance anticipatrice de chaleur de l ancien thermostat voir la Fig 1 Fig 1 Résistance anticipatrice de l ancien thermostat exemple 4 Inscrire le chiffre vers lequel pointe le doigt de réglage de la résistance anticipatrice de chaleur REMARQUE S il est...

Page 6: ... 5 4 Obstruer l ouverture dans le mur à l aide d isolant pour éviter qu un courant d air chaud ou froid ne nuise au fonctionnement du thermostat Fig 3 Retirer le couvercle du nouveau thermostat Fig 4 Bornes et R et W du nouveau thermostat Fig 5 Connexion droite et connexion enroulé ÉTAPE 4 INSTALLATION DU NOUVEAU THERMOSTAT AU MUR 1 Placer le thermostat sur le mur Placer un niveau sur le dessus du...

Page 7: ...mposer le numéro d assistance sans frais de Honeywell 1 800 468 1502 Avant de composer assurez vous d avoir en main l information suivante Numéro de modèle du thermostat et code de date voir la Fig 6 pour savoir où trouver le numéro de modèle et le code de date Type de système de chauffage p ex gaz ou mazout air chaud eau chaude Systèmes de chauffage Réglage de la résistance anticipatrice de chale...

Page 8: ...0 de fibres post consommation 69 1696EF J S 9 03 www honeywell com Solutions de régulation et d automatisation Honeywell International Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Reviews: