background image

9

69-1081—3

STEP 5. MOUNT THE THERMOSTAT

STEP 6. CUSTOMIZE YOUR THERMOSTAT

Your Honeywell CT3611 thermostat comes preset to the most commonly used settings. The settings are:
— Auxiliary and/or Emergency Heat type.
— Smart Response™ technology on.
— Temperature °F.
— 12-hour clock format.

You can change any or all of these settings.

IMPORTANT

Always press the keys with your fingertip or a similar blunt tool. Sharp instruments like pens and pencil 
points can damage the keyboard.

69-1081.fm  Page 9  Wednesday, May 18, 2005  9:03 AM

Summary of Contents for CT3611

Page 1: ...ode demploi en français composer le 1 800 468 1502 Table of Contents Step 1 Prepare for Installation 5 Step 2 Remove Old Thermostat 5 Step 3 Mount thermostat Wallplate 6 Step 4 Wire Wallplate Terminals 7 Step 5 Mount the Thermostat 9 Step 6 Customize Your Thermostat 9 Step 7 Set the Clock 11 Step 8 Programming 12 Step 9 Operating Your Thermostat 15 Step 10 Set the Fan and System Switches 17 If You...

Page 2: ...le or set your own This manual answers many of the questions that can arise as you become familiar and comfortable with your Honeywell thermostat the state of the art in home comfort controls Read these instructions carefully Failure to follow these instructions can damage the product or cause a hazardous condition MERCURY NOTICE If this thermostat is replacing a control that contains mercury in a...

Page 3: ... HEAT OFF COOL DIGITAL DISPLAY SET CURRENT DAY TIME SETS CURRENT TIME AND DAY RUN PROGRAM RETURNS THERMOSTAT TO NORMAL OPERATING MODE HEAT COOL SETTING SWITCHES BETWEEN HEAT SETPOINTS AND COOL SETPOINTS WHILE PROGRAMMING TIME TIME SETS TIME FORWARD OR BACK DAY SETS DAY OF THE WEEK HOLD TEMP SETS A HOLD TEMPERATURE SETTING AND ACTIVATES VACATION HOLD FEATURE DAYLIGHT TIME SELECTS STANDARD TIME OR D...

Page 4: ...AYS EITHER ROOM OR SET TEMPERATURES SHOWS SMART RESPONSE IS OFF CONVENTIONAL RECOVERY IS ON SHOWS THERMOSTAT IS PROCESSING INFORMATION AND WAITING TO CALL FOR HEAT OR COOL SHOWS SMART RESPONSE IS CHANGING THE TEMPERATURE TO MEET THE CURRENT PROGRAMS SHOWS THAT THERMOSTAT IS CALLING FOR HEAT OR COOL SHOWS CURRENT SYSTEM KEY POSITION EM HEAT HEAT OFF COOL SHOWS CURRENT PROGRAM PERIOD OR PERIOD BEING...

Page 5: ...tioning dealer To avoid compressor damage do not operate the cooling system when outdoor temperature is below 50 F 10 C q Turn off power to the system at the furnace or the fuse circuit breaker panel q Carefully unpack your new thermostat and wallplate Save package of screws instructions and receipt q Remove the cover from the old thermostat If the cover does not snap off when pulled firmly from t...

Page 6: ... Remove the wallplate from the wall Drill two 3 16 in holes in wall if drywall as shown For materials such as plaster or wood drill 7 32 in holes where marked Gently tap the provided anchors into the drilled holes until they are flush with the wall q Reposition the wallplate over the holes Pull the wires through the wiring opening Loosely insert mounting screws into each of the holes q Level the w...

Page 7: ...eeded see page 21 q Loosen the terminal screws Slip each wire beneath its matching terminal Wraparound and straight connections are both acceptable see illustration Tighten the terminals q Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation q Match the terminals from your old thermostat to the terminals on the CT3611 Find the column from T...

Page 8: ...Y1 to Y and W2 to W2 d Use electrical tape to tape off the end of the wire and push the taped end back into the wall wiring hole Table 1 Terminal Designations on Old and New Thermostats CT3611a Typical Terminal Designations from the Existing Thermostat Alternative Terminal Designations Function Description Trane American Standard Lennox York Borg Warner General Electric Rheem Ruud C C C or X C B X...

Page 9: ...The settings are Auxiliary and or Emergency Heat type Smart Response technology on Temperature F 12 hour clock format You can change any or all of these settings IMPORTANT Always press the keys with your fingertip or a similar blunt tool Sharp instruments like pens and pencil points can damage the keyboard 69 1081 fm Page 9 Wednesday May 18 2005 9 03 AM ...

Page 10: ... efficiency furnace 90 or better 6 Gas or oil forced air furnace 9 Electric heat system preset To change your Emergency Heat type q Press until display shows your Emergency Heat type q Press Time to move to next feature or to return to main display Smart Response Technology Feature Number 13 Smart Response technology options are 0 Smart Response technology on preset 1 Smart Response technology off...

Page 11: ...Press once q Press to return to main display Factory Set Function Feature Number 37 Do not change this setting STEP 7 SET THE CLOCK Set Current Day and Time NOTE On initial power up the screen flashes 1 00 pm until you press a key q Press q Press until screen shows current day q Press Time or until screen shows current time Tapping the will advance the time in one hour increments M13344 Run Progra...

Page 12: ...u get ready for work or school This is a higher temperature during the heating season and a lower temperature during the cooling season The program period you can set for an energy saving temperature while you are away at work or school This is a lower temperature during the heating season and a higher temperature during the cooling season The program period when you want the house at a comfortabl...

Page 13: ...by programming the wake time and temperature for one day q Press and release q Press until the desired day displays Mon Tue Wed Thu Fri Sat Sun q Press time or until the desired time shows in the display Period Default Setting Monday Mon Tuesday Tue Wednesday Wed Thursday Thu Friday Fri Saturday Sat Sunday Sun Wake Time 6 00AM Heata 70 F 21 C Coolb 78 F 25 5 C Leave Time 8 00AM Heata 62 F 16 5 C C...

Page 14: ... The first day is now programmed q Repeat each step in Program the First Day for the rest of the week NOTE After the first day is programmed you can copy that day to any other day using procedure in Copy a Day q Press when the entire week is programmed Copy a Day Your thermostat can copy program settings from one day to another q Press or to enter programming mode q Press until the display shows t...

Page 15: ...re clear q Repeat the above steps for each period to be cleared q Press STEP 9 OPERATING YOUR THERMOSTAT Change Temperature Setting Until the Next Program Period Temporary Change q Press or until the screen shows the desired temperature setting NOTE The temporary temperature setting is displayed for about 3 seconds and then the room temperature is dis played Temporary appears in the display The se...

Page 16: ...nt the program to restart NOTE If the Vacation Hold needs to be cancelled before the designated time press to return to the program Daylight Savings Time Key This feature allows you to switch between standard time and daylight savings time q Press during fall to set the time back one hour q Press during the spring to set time forward one hour DST is displayed when operating on daylight savings tim...

Page 17: ...d air circulation or for more efficient central air cleaning In a heat only system fan runs continuously only if fan relay is connected to the G thermostat terminal Fan Auto Normal setting for most homes The equipment controls the fan operation Then set the system switch Heat The thermostat controls your heating system Off Both the heating and cooling systems are off Cool The thermostat controls y...

Page 18: ...ped and reset it if necessary Make sure the power switch at the equipment is in the On position and set it to On if it is in the Off position Wait five minutes for the system to respond Set the system switch to Heat Cooling does not come on Make sure the cooling setpoint is below the room temperature Make sure the circuit breaker is not tripped and reset it if necessary Make sure the system switch...

Page 19: ...ached The heating setting range is 40 F to 90 F 4 5 C to 32 C The cooling setting range is 45 F to 99 F 7 C to 35 C Temperature change occurs at the wrong times 1 Check the program times for the period in question 2 Make sure the AM and PM settings are correct 3 Make sure the current time and day settings are correct 4 Reprogram any incorrect settings NOTE If your thermostat is set for Smart Respo...

Page 20: ...your lifestyle the construction of your home and your heating cooling system You can turn off Smart Response technology by selecting Conventional Recovery Honeywell does not recommend this because the auxiliary heat comes on once the program time begins and run continuously until the setpoint is reached See Step 6 Customize Your Thermostat System Operating in Energy Savings Mode Recovery Begins Re...

Page 21: ... THERMOSTAT B R W2 L C E W1Y O G M15110B L2 L1 HOT HEAT CHANGEOVER VALVE EQUIPMENT MONITOR AUX HT RELAY COOL CHANGEOVER VALVE FAN RELAY EM HEAT RELAY 1ST STAGE HEAT RELAY COMPRESSOR RELAY 2 Typical hookup of CT3611 1 2 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED 2 LEAVE FACTORY INSTALLED JUMPER IN PLACE 1 THERMOSTAT B R W2 L C E W1Y O G M15113A L2 L1 HOT HEAT CHANGEOV...

Page 22: ...lden Valley MN 55422 3992 Scarborough Ontario M1V 4Z9 This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywells sole responsibility shall be to repair or replace the product within the terms stated above HON...

Page 23: ...g this warranty please write our Customer Relations Center Honeywell Inc 1885 Douglas Dr N Golden Valley MN 55422 3992 or call 1 800 468 1502 Monday Friday 7 00 a m to 5 30 p m Central time In Canada write Retail Products ON30 Honeywell Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 69 1081 fm Page 23 Wednesday May 18 2005 9 03 AM ...

Page 24: ... 1081 3 J H Rev 11 01 www honeywell com yourhome Home and Building Control Home and Building Control Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 69 1081 fm Page 24 Wednesday May 18 2005 9 03 AM ...

Reviews: