background image

Model: CO30XE

Modelo: CO30XE

Power rating: 288 Watts

Potencia: 288W

Voltage rating: 120 Volt AC, 60Hz

Tensión: 120V~60Hz

Made in China

Fabricado en China

Customer Support : 1-800-474-2147
Centro de servicios al cliente: 1-800-474-2147

For product inquiries or support, visit www.honeywellaircoolers.com

Para consultas sobre productos o soporte técnico visite: www.honeywellaircoolers.com

Portable Evaporative Air Cooler

for Outdoor, Indoor & Commercial Use

Enfriador de aire portátil por evaporación

Ideal para Uso Externo, Interno y Comercial

OWNER’S MANUAL

Read and save these instructions before use

MANUAL DEL USUARIO

Lea y guarde estas instrucciones antes de usar

Summary of Contents for CO30XE

Page 1: ...For product inquiries or support visit www honeywellaircoolers com Para consultas sobre productos o soporte técnico visite www honeywellaircoolers com Portable Evaporative Air Cooler for Outdoor Indoor Commercial Use Enfriador de aire portátil por evaporación Ideal para Uso Externo Interno y Comercial OWNER S MANUAL Read and save these instructions before use MANUAL DEL USUARIO Lea y guarde estas ...

Page 2: ...aporative air cooler requires cross ventilation Turn ON and enjoy the cooling breeze Note Start with LOW speed and gradually increase to higher speed for optimum cooling performance Note Please make sure the household power voltage matches the product specifications 1 2 3 QUICK START GUIDE 1 2 3 ...

Page 3: ... carefully before setting up and operating the unit and please keep this instruction manual for future reference This manual is designed to provide you with important information needed to setup operate maintain and troubleshoot your cooler Failure to follow these instructions may damage and or impair its operation and void the warranty Fill Water Function Buttons Low water alarm and cooler locati...

Page 4: ...ead Place the cooler in front of an open door or window Ensure that there is adequate cross ventilation in the room by leaving a door or window open opposite the cooler Following these guidelines will ensure your cooler will work as effectively as possible Not an Air Conditioner Important Please Read The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigeran...

Page 5: ...imize energy efficiency and keep costs low Warm air is drawn into the cooler through the Honeycomb Cooling Media Water pumped from the tank pours over the honeycomb media As the warm air passes through the media the water absorbs the heat naturally cooling and humidifying the air A fan propels the cooled air out into the room This no compressor system cools naturally efficiently and inexpensively ...

Page 6: ... enclosed spaces It must be kept level and there must be water in the water tank The room should have doors and windows opened to allow free air flow The evaporative air cooler works best when placed near an open window so that outside air is drawn into the evaporative air cooler the air circulates in the room then exits via the door The maximum cooling effect is felt when a person is in the flow ...

Page 7: ...over it with rugs or runners Keep the cord away from areas where it may be tripped over Always unplug the product before refilling the water tank Always unplug the appliance from the power source before cleaning servicing or relocating the unit Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug end only never pull the cord DO NOT use the product in ...

Page 8: ...with this appliance packaging or plastic bags If the unit is damaged or if it malfunctions do not continue to use it Refer to the Troubleshooting Guide page 18 and contact the service center Place the unit on a level floor This product is not intended for use in wet or damp locations DO NOT use in bathrooms Never locate the product where it may fall into a bathtub or other water container Store in...

Page 9: ...and connections must be waterproof Be sure the connections to the air cooler never get wet Your unit is waterproof but everything attached to it must be waterproof too Set up your unit so it cannot be tripped over or wobble loose It must rest on a solid Warning To reduce the risk of fire or electric shock do not use this appliance with any solidstate speed control device support SAFETY RULES ...

Page 10: ...nt Panel Water Level Indicator Remote Control Latch Right Side Panel Water Fill Door 1 2 3 4 5 6 7 8 Ice Compartment Lid 9 10 11 12 13 14 15 16 17 Water Regulator under part 9 18 PARTS DESCRIPTION 1 11 12 17 14 15 16 13 2 4 3 5 8 9 18 10 ACCESSORIES Remote Control 2 AAA Batteries not included 7 Drain Plug ...

Page 11: ...9 CONTROL PANEL USE OPERATION Lighted Display Icons Low water level in tank Cool Speed Natural Low speed Medium speed High speed Swing Time delay set NATURAL ...

Page 12: ...speed will switch to low SPEED Press the FAN or SPEED button repeatedly and the speed will change The indicator light will show the selected speed COOL To begin cooling the desired area press the COOL button The indicator light will come on and the water pump will operate You will feel the cooler air after the Honeycomb Cooling Media is completely wet COOL SPEED Low Speed Medium Speed High Speed ...

Page 13: ... Press the TIMER button until the indicator light comes on to your desired timer Once the set time has passed the unit will automatically shut off The Timer function allows you to program the unit for up to 8 hours of use TIMER SWING Press the SWING button The indicator light will come on and the louvers will begin to move from right to left automatically Manually adjust the horizontal louvers to ...

Page 14: ...p inside the unit will be cut off to protect the life of the pump To disengage the alarm function turn off and unplug the unit from the power outlet and fill the tank with water above the minimum level To turn off the alarm function and continue to use it in FAN mode turn off the unit and turn the unit on If the COOL button is pressed again without filling the tank with water the low water alarm w...

Page 15: ...the Honeycomb Cooling Media This results in less water evaporation and reduces the effect When the Water Regulator is set to MAX the water pump distributes the maximum amount of water to the Honeycomb Cooling Media This results in maximum water evaporation and the cooling performance improves Water Regulator USE OPERATION 13 ...

Page 16: ...battery compartment at the back of the remote control and insert two new AAA dry cell batteries Care must be taken to insert the batteries according to the correct polarity markings shown inside the battery compartment Always point the remote control signal transmitter towards the unit when operating Make sure that the signal path is not obstructed Remove the batteries if the unit is not going to ...

Page 17: ... tank open the Water Fill Door located below the right side panel and fill water to the Max Level as indicated on the Water Level Indicator Do not fill water above the Max water level mark For better cooling performance it is recommended to put ice cubes inside the ice compartment located on the top of the cooler After refilling the water tank and loading ice close the water fill door connect the ...

Page 18: ...nd allow the tank to empty see parts description on page 8 Once the tank is empty unlock the latches on both sides and lift off the cooler top section as shown in the figure and place it vertically on the floor Be careful not to bend the water pickup tube that hangs below the unit Refill the water tank with clean water and drain it completely Clean the water tank with detergent or a damp cloth and...

Page 19: ...refill with fresh water especially if the tank has not been cleaned in a long time The cleaning frequency for the Honeycomb Cooling Media depends on local air and water conditions In areas where the mineral content of water is high mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow Draining the water reservoir and refilling with fresh water at least once a week will...

Page 20: ...w or no water in tank when COOL is selected Refill water tank Odors When the Cooler is new When the unit is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate within a few hours of initial use If the Cooler has been used There may be an algae issue Replace the Honeycomb Cooling Media Damaged Pump or Calcium deposits on blower Contact service center PROBLEM P...

Page 21: ...trol Panel Try activating with the Remote Control If the unit responds then it may be the Control Panel that is experiencing problems Contact Customer Service Center If neither Remote Control nor Control Panel works contact Customer Service Center PROBLEM POSSIBLE CAUSE SOLUTION Customer Support 1 800 474 2147 19 TROUBLESHOOTING GUIDE ...

Page 22: ...0V 60Hz 288 Watts 8 Gallons Honeycomb 18 W x 13 9 D x 33 7 H inch 24 9 lbs Voltage Frequency Wattage Water Tank Capacity Cooling Media Product Dimension Net Weight ELECTRICAL WIRING DIAGRAM BU 20 TECHNICAL SPECIFICATIONS ...

Reviews: