background image

3

USE & OPERATION (CONTINUED)

EN

FUNCTION BUTTONS  (CONTINUED)

MODE (COOL)

Press the MODE button to select COOL mode. Pressing the MODE button until COOL is illuminated 
on the control panel activates evaporative cooling. The water pump will operate and you will feel the 
cooler air after the Honeycomb Cooling Media is completely wet.

Pressing the MODE button again will deactivate COOL light on the control panel, switching off both 
evaporative cooling function altogether.

Note: 

When the cooling function is switched OFF, the unit can still function in a fan only mode 

(without evaporative cooling).

In cooling mode, Honeywell Air Coolers provide cool, moist air through the

 

evaporation of water. 

There is a manual Water Regulator knob located in

 

the ice compartment of the unit. This allows you 

to adjust the amount of

 

water pumped over the Honeycomb Cooling Media, thus helping to control

 

cooling and humidification levels.

When the Water Regulator is set to MIN, the water pump distributes a

 

minimal amount of 

 

water to the Honeycomb Cooling Media. This 

results in

 

less water evaporation and reduces the cooling effect.

When the Water Regulator is set to MAX, the water pump distributes  
the maximum amount of water to the Honeycomb Cooling Media. This  
results in maximum water evaporation and the cooling performance 
improves.

ROOM COOLING AND HUMIDIFYING

Water Regulator 

MAX

MIN

Summary of Contents for CL603AE

Page 1: ...lhomecomfort com Portable Evaporative Air Cooler User Manual Read and save these instructions before use EN Enfriador de Aire Evaporativo Portátil Manual de Instrucciones Lea y guarde estas instrucciones antes de usar la unidad ES Model Modelo CL603AE ...

Page 2: ...PTION EN 1 Control Panel 7 Water Level Indicator 2 Handle 8 Remote Control 3 Louvers 9 Water Fill Door 4 Power Cord Plug 10 Continous Water Supply 5 Casters 11 Drain Plug 6 Ice Compartment Lid 11 9 8 5 4 10 3 2 1 6 7 ...

Page 3: ...l the desired time duration setting is selected When the set time has passed the unit will automatically turn off unit remains in Standby mode until power cord is unplugged from electrical socket The TIMER function allows you to program the unit for up to 8 hours of use SWING Press the SWING button until the SWING indicator light is illuminated on the control panel The louvers will begin to move l...

Page 4: ...cooling In cooling mode Honeywell Air Coolers provide cool moist air through the evaporation of water There is a manual Water Regulator knob located in the ice compartment of the unit This allows you to adjust the amount of water pumped over the Honeycomb Cooling Media thus helping to control cooling and humidification levels When the Water Regulator is set to MIN the water pump distributes a mini...

Page 5: ...wn inside the battery compartment Always point the remote control signal transmitter towards the unit when operating Make sure that the signal path is not obstructed Remove the batteries if the unit is not going to be used for an extended period of time Do not drop the remote control Do not mix different types of batteries such as alkaline carbon zinc or rechargeable batteries Do not mix old and n...

Page 6: ...OOLER LOCATION Locate the male connector at one end of the garden hose Insert the garden hose connector into the water inlet valve of the cooler Screw and tighten the water inlet valve onto the threaded part of the garden hose connector making sure the hose connector is secured to ensure there will be no leaks If there is a leakage the hose and the water inlet valve may not be connected properly T...

Page 7: ...it in COOL mode with inadequate water may cause pump failure Note The water capacity refers to the total volume of water that can be contained within the air cooler water tank and water distribution system The water capacity in the tank at the Max indicator level may be lower than the actual water capacity of the air cooler Note This unit does not have a mark indicating the minimum water level req...

Page 8: ...nection or by filling the tank up to the maximum indicator level Plug in and switch ON again To deactivate the alarm and continue using the unit as a fan without evaporative cooling switch the unit OFF and then ON again The Low Water Alarm will not activate in Fan only mode The Low Water Alarm will sound again if the COOL function is activated while the water tank is still empty Applicable for mod...

Page 9: ...ineral content of water is high mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits If mineral deposits remain on the Honeycomb Cooling Media the media should be removed and washed under fresh water The media should be cleaned every two months or sooner depen...

Page 10: ...ll International Inc makes no representations or warranties with respect to this product This product is manufactured by Airtek Int l Corp Ltd subsidiary of JMATEK Ltd EN Hecho en China 2018 JMATEK Limited Todos los derechos reservados La marca Honeywell es usada bajo licencia de Honeywell International Inc Honeywell International Inc no representa ni garantiza este producto Este producto es fabri...

Reviews: