background image

OWNER’S MANUAL

Read and save these instructions before use

使用者操作手冊

在使用該產品前請詳讀本操作手冊

Model: CL20AE

機型

: CL20AE

Power rating: 230 Watts

Voltage rating: 110 Volt AC, 60Hz

消耗功率

:

 230 Watts

使用電壓

:

 110 Volt AC, 60Hz

For product inquiries or support, visit www.honeywellaircoolers.com

有關產品查詢及資訊,請上www.honeywellaircoolers.com網站

Portable Evaporative Air Cooler

for Indoor Use

移動式冷卻器(水冷器)

建議室內使用

Customer Support: 0800-888-753

消費者服務

:

 0800-888-753

Made in P.R.C.

中國製造

Summary of Contents for CL20AE

Page 1: ...230 Watts Voltage rating 110 Volt AC 60Hz 消耗功率 230 Watts 使用電壓 110 Volt AC 60Hz For product inquiries or support visit www honeywellaircoolers com 有關產品查詢及資訊 請上www honeywellaircoolers com網站 Portable Evaporative Air Cooler for Indoor Use 移動式冷卻器 水冷器 建議室內使用 Customer Support 0800 888 753 消費者服務 0800 888 753 Made in P R C 中國製造 ...

Page 2: ...open door or window Note Evaporative air cooler requires cross ventilation Turn ON and enjoy the cooling breeze Note Start with LOW speed and gradually increase to higher speed for optimum cooling performance Note Please make sure the household power voltage matches the product specifications ...

Page 3: ...1 2 3 快速入門指引 注水及插入標準電源插座 使用本設備儘可能在一個寬敞的空間或靠近 門窗邊使用 注意 本移動式冷卻器 水冷器 需要考慮室內空氣的循 環及交換 啟動本設備的開關 並享受清涼的微風 注意 開始請由低速逐步提高到更高的速度 以獲得最佳 的散熱性能 注意 請確認使用電源及電壓符合產品規格 ...

Page 4: ...ons carefully before setting up and operating the unit and please keep this instruction manual for future reference This manual is designed to provide you with important information needed to setup operate maintain and troubleshoot your cooler Failure to follow these instructions may damage and or impair its operation and void the warranty Fill Water Function Buttons Room Cooling and Humidifying R...

Page 5: ...器 ...

Page 6: ...ead Place the cooler in front of an open door or window Ensure that there is adequate cross ventilation in the room by leaving a door or window open opposite the cooler Following these guidelines will ensure your cooler will work as effectively as possible Not an Air Conditioner Important Please Read The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigeran...

Page 7: ...佳的冷卻效 果 請注水至水箱內最高水位刻度 將冰塊放入置冰室 然後打開電源開關開始使用 冷卻器放置位置 室內 重要 請仔細閱讀 移動式冷卻器 水冷器 請放置在空氣流通的地方 靠近開放的門窗邊使用 確保有足夠 的空氣流通 或在房間裡留一個開放的門或開放的窗 相對會較涼爽及冷 冷氣房可 不再此限制 依循這些規則 將可確保您的冷卻器將達到最好的效能 不是一般的冷凍空調器 重要 請仔細閱讀 移動式冷卻器 水冷器 不是一般的冷凍空調器 它不使用壓縮機或製冷劑氣體 冷媒 不應該被預期有冷凍空調器冷卻的效率 ...

Page 8: ... the Honeycomb Cooling Media Water pumped from the tank pours over the Honeycomb Cooling Media As the warm air passes through the media the water absorbs the heat naturally cooling and humidifying the air A fan propels the cooled air out into the room This no compressor system cools naturally efficiently and inexpensively Pump Water Honeycomb Cooling Media Evaporative Air Cooling Mechanism Warm an...

Page 9: ...且有效地降低了用電成 本 當熱空氣被吸入冷卻器 先通過活性碳的濾網 再進入蜂巢式冷卻濾材Honeycomb 同一時間 水箱幫浦汲起的水將會佈滿整個蜂巢式冷卻濾材Honeycomb 熱空氣通過 蜂巢式冷卻濾材Honeycomb間格內的細小水分子 將會吸收熱空氣中的熱能 就會有自 然冷卻及加濕空氣 最後由風扇將冷卻的空氣送出進入室內 這個無壓縮機系統的自然 冷卻效應有效率且價廉 汲水幫浦 水 蜂巢式冷卻濾材Honeycomb 移動式冷卻器 水冷器 的蒸發冷卻機制 溫暖及乾燥 的空氣 涼爽和潮濕 的空氣 ...

Page 10: ... placed near an open window so that outside air is drawn into the evaporative air cooler circulates in the room then exits via the door The maximum cooling effect is felt when a person is in the flow of air coming out of the evaporative air cooler The evaporative air cooler can also be used to humidify dry air during cool weather To be used for humidification the windows and doors should be closed...

Page 11: ...持水平 水箱需保持充滿水 房間內 的門和窗戶需打開 讓空氣保持流通 冷卻器工作時 最好放 置在寬廣的空間或門窗邊 好讓外部的空氣容易被吸入到冷卻 器中 空氣才足以循環 在如此空氣流通及冷卻循環的環境 中 將容易達到最好的冷卻效率 移動式冷卻器 水冷器 也適用在乾燥的空氣環境中 有加濕的 功效就好像是一台加濕機 若用於需加濕的環境中 窗戶及門 就必須關閉 讓加濕空氣持續積累 初次使用本產品 蜂巢式冷卻濾材Honeycomb可能有異味 但持續使用它 大約一個星 期左右味道將會減少或消失 我們建議 在門窗開啟 空氣流通較好 的房間使用 冷氣房可不再此限制 我們不建議 在門窗緊閉 空氣流通較 差的房間使用 冷氣房可不再此限制 注意 ...

Page 12: ...unplug the product before refilling the water tank Always unplug the appliance from the power source before cleaning servicing or relocating the unit Remove the power cord from the electrical receptacle by grasping and pulling on the power cord plug end only never pull the cord DO NOT use the product in areas where gasoline paint or other flammable goods and objects are stored When using the COOL ...

Page 13: ...後的商品 外觀及所有配件 是否正常 發現任何損壞的電源線或插頭 請不要使用 請避免將電源線捲曲或蓋藏在任何物品或地毯下 請避免可 能被電源線絆倒 補充水箱中的水之前 請務必拔下電源線插頭 清洗 維修 搬遷之前 請務必拔下電源線插頭 從插座拔下電源線時 請抓住電源線插頭端 切勿拉扯電源 線 切勿與汽油 油漆 其他易燃物品共同和儲存收藏 當啟動 COOL 功能時 請檢查水箱中的水是否足夠 啟動 COOL 功能時 若水幫浦無法汲取水箱中的水 將可能導致水 幫浦的損壞 請勿嘗試自行維修或調整任何功能及零件 因為這可能會導 致保固失效 觸電的危險 水位指示器 ...

Page 14: ... continue to operate it Refer to the troubleshooting section and seek professional advice Place the unit on a level floor This product is not intended for use in wet or damp locations DO NOT use in bathrooms Never locate the product where it may fall into a bathtub or other water container Store in a dry area when not in use This appliance is not intended for use by persons including children or e...

Page 15: ...產品 且可能導致觸電或火災 當蜂巢式冷卻濾材Honeycomb卸除時 請勿進行操作 因為 這可能會超過負載和損壞馬達電機 請避免長時間在無人看顧的狀態 讓設備一直運轉而無人操 作 請避免讓孩子自行操作設備及包裝外箱 包裝塑料袋 如發現有損壞或故障 無法繼續使用 請參閱說明書故障排 除部分或請諮詢專業意見 0800消費者專線 請保持機體放置在水平地面上使用 本設備不適合在潮濕的地方使用 請勿在浴室中使用 當設備不使用時 應存放在乾燥的地方 當兒童或年長者使用時 請特別住意他們使用設備的過程 移動設備時 請牢牢握住機體 ...

Page 16: ...r Ornament Power Cord Plug Casters Ice Compartment Lid Vertical Louvers Manual Movement 1 2 3 4 5 6 7 8 9 Front Panel Water Level Indicator Remote Control Remote Control Holder Right Side Panel Water Fill Door Drain Plug 10 11 12 13 14 15 16 1 2 3 4 5 7 8 11 12 13 14 15 16 PARTS DESCRIPTION 7 10 9 6 ...

Page 17: ......

Page 18: ...CONTROL PANEL SPEED TIMER MODE SWING High Mid Low Sleep Cool 8hr 7hr 6hr 5hr 4hr 3hr 2hr 1hr POWER Speed Control Swing Control Power Button Timer Control Mode Button USE OPERATION 8 ...

Page 19: ......

Page 20: ...utton again The cooler will start automatically at medium speed After a few seconds the speed will switch to low SPEED Press the SPEED button repeatedly and the speed will change The indicator light will show the selected speed MODE COOL To begin cooling the desired area press the MODE button The indicator light will come on and the water pump will operate You will feel the cooler air after the ho...

Page 21: ...器 器 器 器 器 ...

Page 22: ...et time has passed the unit will automatically shut off The Timer function allows you to program the unit for up to 8 hours of use Louvers Movement SWING Press the SWING button The indicator light will come on and the louvers will begin to move from right to left automatically Manually adjust the horizontal louvers to change vertical airflow 10 ...

Page 23: ...器 ...

Page 24: ...t Thus reducing the humidity inside the room When the water regulator is set to MAX the water pump distributes the maximum amount of water to the honeycomb media This results in maximum water evaporation and the cooling performance improves Thus increasing the humidity inside the room Water Regulator is located inside the ice loading compartment Regulator knob can be rotated using your own hands N...

Page 25: ......

Page 26: ... two new AAA dry cell batteries Care must be taken to insert the batteries according to the correct polarity markings shown inside the battery compartment Always point the remote control signal transmitter towards the unit when operating Make sure that the signal path is not obstructed Remove the batteries if the unit is not going to be used for an extended period of time Do not drop the remote co...

Page 27: ...器 打開遙控器背面的電池槽 放入兩個新的AAA 4號 乾電池 必須根據正確的極性 標記小心放入的電池 使用遙控器時需正確指向設備發訊號 確認遙控器訊號路徑不受阻礙 如長時間不使用設備 請將遙控器內電池取出 避免摔落遙控器 不是充電電池 是不能被充電的 不要混合使用不同類型的電池 如鹼性電池 碳鋅電池或充電電池 不要混合使用新舊電池 請不要使用電力不足的電池產品 器 ...

Page 28: ...ater tank when water level is low Do not fill water above the Max water level mark Check water level in the tank before running the COOL function Please be sure water in the tank is always above minimum water level mark Running the unit with inadequate water may cause pump failure If ice is available you may add ice in the top compartment to enhance the cooling performance Unplug from power when r...

Page 29: ...器 器 器 器 ...

Page 30: ...roduct is not in use store the unit in a dry place out of direct sunlight Turn the power OFF and disconnect the unit from power supply Move the unit to a location where it can be drained and remove the drain plug see parts description on page 7 Once the tank is empty refill with clean water and drain it again This should be repeated weekly to maintain the integrity of the unit and to remove partic...

Page 31: ...器 器 器 器 器 器 ...

Page 32: ... year or as necessary Draining the water tank and refilling it with fresh water at least once a week will greatly reduce mineral deposits in the pads and help extend the life of the Honeycomb Cooling Media Do not run the unit in COOL mode with stale water in the tank It is recommended to empty the tank and refill it with fresh water if the water has been standing inside the tank for an extended pe...

Page 33: ...器 器 器 器 ...

Page 34: ...n COOL function from remote or control panel Low or no water in tank when COOL is selected Refill water tank Odour When the Cooler is new When the unit is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate within a few hours of initial use If the Cooler has been used There may be an algae issue Replace the Honeycomb Cooling Media Damaged Pump or Calcium depo...

Page 35: ...器 器 器 器 器 器 ...

Page 36: ...l panel Damaged Control Panel on unit Try to activate the unit with the Remote Control If the unit responds then the Control Panel on the unit may be experiencing problems contact the Customer Service Center If neither the Remote Control or the Control Panel is working contact the Customer Service Center PROBLEM POSSIBLE CAUSE SOLUTION 17 ...

Page 37: ...器 器 器 ...

Page 38: ...eycomb 480 L x 370 W x 830 H mm 10 3 Kg Voltage Frequency Wattage Water Tank Capacity Cooling Media Product Dimension Net Weight TECHNICAL SPECIFICATIONS ELECTRICAL WIRING DIAGRAM COOL SWING PUMP PLUG IN PLUG COOL F R L N PCB H M L N CAPACITOR M M 18 ...

Page 39: ...COOL SWING PUMP PLUG IN PLUG COOL F R L N PCB H M L N CAPACITOR M M ...

Page 40: ... 888 753 2014 AirTek Int l Corp Ltd All rights reserved The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representations or warranties with respect to this product This product is manufactured by Airtek Int l Corp Ltd ...

Reviews: