8

9

10

11

You have now installed the Chronotherm.  For gas boiler applications, the factory system
settings will not need to be changed (for other applications see below). You can now use
the USER GUIDE to program the unit and demonstrate how it works to the homeowner.

Special Features

Optimisation (Variable
Start Time)

AM-PM/ 24hr Display

Pump Exercise

Upper Temperature Limit

Lower Temperature Limit

Temperature Offset

Proportional Band Width

What do I need to do if I wish
this feature?

Set parameter n.1 in the installer
set-up mode to 1

Set parameter n.3 in the installer
set-up mode to 1

Set parameter n.8 in the installer
set-up mode to 1

Set parameter n.11 in the installer
set-up mode to the desired limit

Set parameter n.12 in the installer
set-up mode to the desired limit

Set parameter n.13 in the installer
set-up mode to the desired offset
value.

Set parameter n.15 in the installer
set-up mode to the desired value

Description

The Chronotherm will adjust the start time in the morning/afternoon so the
desired temperature is reached by the start of the program period e.g. Time
7:00, Temp 21°C. The system will restrict the start time to a max of 3 hours

The end user can have a different clock format display

The circulating pump on hydronic systems can be exercised once a day for 1
minute at mid-day. Useful to prevent the pump from sticking after the summer

The normal upper temperature limit of 30°C can be reduced down to 21°C to
save the homeowner energy.

The normal lower temperature limit of 5°C can be increased up to 16°C to
protect the inhabitants from cold. Useful if the inhabitants include the elderly,
children or disabled

If the Chronotherm is located in a particularly hot/cold location and cannot
be moved because of wiring then the measured/displayed temperature can
be adjusted by +/- 3°C. Useful if the homeowner wants the reading to match
another appliance temperature display

Can be adjusted up to 3°C (default is 1.5°C) to provide better temperature
control (less overshoot). Useful for:
a.  Well insulated homes with over-sized heating systems
b.  Air systems with fast response

Optional
Accessories

Outside Temperature
Sensor

Remote Temperature
Sensor

Automatic Time Setting
(ATS) Module

What do I need to do if I wish
this feature?

1. Fit the sensor (instructions

included in the sensor package)

2. Set parameter n. 10 in the

installer set-up mode to 1

1. Fit the sensor (instructions

included in the sensor package)

2. Set parameter n. 10 in the

installer set-up mode to 2

1. Fit the ATS module
2. Set parameter n. 4 in the

installer set-up mode to 1

Description

An Outside Temperature Sensor can be fitted to your CM67 to allow the
homeowner to display the outside temperature on the Chronotherm display
by using the INFO   button.

A Remote Temperature Sensor can be fitted to your CM67 to allow the
Chronotherm to control the temperature from another room e.g. in a
commercial premises where the public may adjust keys.

The ATS module picks up a time signal daily from a European transmitter, so
you never need to set or adjust the time.

Move the slider to
the OFF position.
Press and hold
INFO   button and
press PROG 3,4
together.

Press TEMP 

 or 

 to change factory setting.

The display will flash indicating that a change has
been made.

Press INFO   button to confirm the change is ok.
The display will stop flashing indicating that the new
value has been stored.

Adjust other settings using the Installer Set-
Up Mode - Settings Table 
on the next page.

To exit the Installer Set-Up Mode move the
slider to the AUTOmatic or MANual position.

1

2

3

4

5

6

7

7

1

Installer Set-Up Number

(Press 

 + or - to change)

e.g. 

1 = Optimisation

Abbreviated Set-Up Description

e.g. 

0P = Optimisation

Factory Setting or New Choice

(Press Temp 

 or 

 to change)

e.g. 

0 = Optimisation disabled

e.g. 

1 = Optimisation enabled

Installer Set-Up Mode

Selected

Category 1 Installer Set-Ups

1

Once you have inserted the battery cartridge,
after a pause the unit will display information.
If this does not happen or the display shows
the 

 symbol please refer to the ‘trouble

shooting’ section in the CM67 user guide.

What else will the Chronotherm do?

•

Cover Specific Applications

•

Perform Special Features

•

Support Optional Accessories

Installer Set-Up Mode

1

Press 

 + or -

 to go to the next parameter and follow

steps 3 & 4 to make changes.

1

Specific Application

Heating

Air-
conditioning

What do I need to change?

Note:
a. To change Cycle/Hour, please go to parameter n. 9 in the installer

set-up mode.

b. To change Minimum ON Time, please go to parameter n. 2 in the

installer set-up mode

No action required

1. Set Minimum ON Time to 4 minutes.
2. Set Cycle/Hour to 3.

Set Cycle/Hour to 12.

No action required

1. Configure the Chronotherm for electric heating (set parameter n.7

in the installer set up mode to 1)

2. Set Cycle/Hour to 12

1.  For cooling application only, set the Chronotherm to cooling (set

parameter n.6 in the installer set-up mode to 0)

2.  For heat/cool application, set the Chronotherm accordingly to

required mode of operation by changing parameter n.6 in the
installer set-up mode.

winter = heating    summer = cooling

Explain to the end-user how to implement the change-over and ensure that the
appropriate time and temperature profile is established for heating and cooling

1.  Set Minimum ON Time to 4 minutes.
2.  Set Cycle/Hour to 3.

No action required

Setting

Cycle/

Minimum

Hour

ON Time

6

1

3

4

12

1

6

1

12

1

3

4

6

1

Gas Boilers
(<30KW)

Oil Boiler

Thermal Actuator

Zone Valve

Electric Heating
(for applications
<8A)

Heat Pump/Air
conditioner

Fan Coil