background image

Installation

42009636-005 R3

1

honeywell

Chronotherm

Parameters

Optimisation

Minimum ON Time

AM-PM / 24hr Display

Accessory Module Type

RESET Time / Temperature
Program

Heat / Cool Operation

Electric Heat

Pump Exercise

Cycle Rate

Second Temperature
Sensor

Upper Temperature Limit

Lower Temperature Limit

Temperature Offset

Pressure Offset
(needed for Weatherstation
accessory only)

Proportional Band Width

Return all Set-Up Features
to Factory Settings

Installer Set-Up Mode - Settings Table

You must now press the PROG 2 key to enter the next section

Installer Set-Up
Number /
Abbreviation
(Press  + or -
key to change)

1:0P

2:0t

3:Cl

4:At

5:rP

6:HC

7:Eh

8:PE

9:Cr

10:SS

11:UL

12:LL

13:tO

14:PO

15:Pb

16:FS

Display

0

1

0

0

1

1

0

0

6

0

30

5

0

0

1.5

1

Factory Setting

Description

Optimisation disabled

1 minute minimum ON time

24 hr clock display

No accessory module
plugged in

Time / Temperature profile
set to factory default
Changes to 0 when one of the
time/temp profiles are changed

Heating Operation

Applications < 3A

Pump Exercise Disabled

6 cycles per hour (cph) for
gas boilers, zone valves and
fan-coil

No sensor fitted

30°C Upper Temp. Limit

5°C Lower Temp. Limit

No offset

No offset

1.5°C Proportional Band

All settings held are the
factory defaults. Changes to
0 when one of the parameter
values are changed

Display/Setting

1

2 to 5

1

1, 2

0

1

0

1

1

3, 9, 12

1, 2

21 to 29

6 to 16

-3 to +3

-99 to +99

1.6 to 3.0

0

1

Optional Setting

Description

Optimisation enabled

2 - 2 minutes
3 - 3 minutes
4 - 4 minutes
5 - 5 minutes

12 hr AM / PM clock display

1 - Auto Time Setting Module
2 - Weatherstation Module

Time / Temperature are as
programmed
To restore the factory profile
set to 1

Cooling Operation

Applications 3 - 8A

Pump Exercise Enabled

3 - 3 cph
9 - 9cph
12 - 12 cph

1 - Outside Temperature
Sensor fitted
2 -Remote Temp. Sensor fitted

21°C to 29°C adjustment in
1°C steps

6°C to 16°C adjustment in 1°C
steps

-3°C to +3°C adjustment in
0.1°C steps

-99 mbar  to +99 mbar
adjustment in 1 mbar steps

1.6°C to 3.0°C adjustment in
0.1°C steps

Settings are as modified
above
To restore the factory profile
set to 1

Installer Set-Up
Category
(Press keys PROG 1
or 2 to select)
 

 

1  2

1

1

1

1

1

2

2

2

2

2

2

2

2

2

2

2

Notes
1) When the Installer Set-Up Mode is initiated, only Category 1  (

 

1) Set-Up Features

are accessible.
Category 2 (

 

2) Set-Up Features are accessed by pressing the PROG. 2 key.

2) Remember to always press the INFO   button to confirm that you want to store your new

Installer Set-Up setting.

3) To exit the Installer Set-Up Mode move the slider to the AUTOmatic or MANual position.

2

3

4  

a

4  

b

4  

c

5

6

1.0-2.5mm²

honeywell

Home Comfort & Systems

Honeywell Control Systems Ltd.

Newhouse Industrial Estate

Motherwell, ML1 5SB

Scotland

http://europe.hbc.honeywell.com

3mm
max.

3mm
max.

This product has been designed with your
environment in mind! Please respect this by
disposing of all packaging, used parts and
eventually the product itself in an environ-
mentally friendly manner.