Portable Evaporative Air Cooler
OWNER’S MANUAL
Read and save these instructions before use
Model: CO301PC
Power rating: 270 Watts
Made in P.R.C.
Voltage rating:
220-240 Volt, 50Hz
Page 1: ...Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model CO301PC Power rating 270 Watts Made in P R C Voltage rating 220 240 Volt 50Hz ...
Page 2: ...Control Panel Functions 8 12 Operating the Unit 13 14 16 18 18 INDEX 1 Read all instructions carefully before setting up and operating the unit and please keep this instruction manual for future reference This manual is designed to provide you with important information needed to setup operate maintain and troubleshoot your cooler Failure to follow these instructions may damage and or impair its o...
Page 3: ...ns on your purchase of this versatile Honeywell Evaporative Air Cooler For optimum cooling performance from your unit fill the water tank with water ice if available to increase its cooling power Please read these instructions carefully ...
Page 4: ...similar to a breeze blowing across a lake This breeze drops the temperature and has a relaxing cooling effect The evaporative air cooler cools the air by means of the evaporation of water When water evaporates into the air the result is a mixture of air and water molecules This chemical change requires heat which is taken from the water molecules resulting in cooler air propelled from the unit ...
Page 5: ... air circulates in the room then exits via the door The maxi mum cooling effect is felt when a person is in the flow of air coming out of the evaporative air cooler The evaporative air cooler can also be used to humidify dry air during cool weather To be used for humidification the windows and doors should be closed to allow the humidified air to accumulate The evaporative air cooler is not an air...
Page 6: ...gasoline paint or other flammable goods and objects are stored When using the COOL setting please check the water tank to ensure it is full Operation of this unit on the COOL setting with an empty tank may result in damage to the water pump DO NOT run power cord under carpeting or cover it with rugs or runners Keep the cord away from areas where it may be tripped over Your cooler runs on 220 240 V...
Page 7: ...d damage the motor DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage the product and could cause an electrical shock or fire DO NOT attempt to repair or adjust any electrical or mechanical functions of the cooler as this may void the warranty DO NOT cover the air inlet or outlet on the appliance as this If the unit is damaged or it malfunctions do not co...
Page 8: ... 3 Front Pad Cover 4 Casters 5 Wheels 6 Water Fill Door 7 Hose Adapter 8 Water Level Indicator 9 Can Holders 10 Top Storage Compartment 11 Rear Pad Cover 12 Cord Wrap 13 Overflow Hole 14 Drainage cap 15 Power Cord Plug 1 2 3 4 5 6 9 10 11 12 13 14 7 8 15 ...
Page 9: ...louvers will begin to move automatically from side to side UP DOWN AIRFLOW To adjust the vertical direction of air flow adjust the horizontal louvers manually POWER Power On 1 Connect the cord to a power outlet the unit will start on Stand by mode indicated by a beeping sound and amber power display 2 Touch POWER to turn the unit on The blue outer power circle will light up and the TIMER will disp...
Page 10: ... and a warning sound will beep for 10 seconds At that moment the pump will be shut off to protect the life of the pump Refill the reservoir with fresh water and turn on the COOL function to enjoy the cool air again SAFETY LOCK CO301PC features safety lock function to prevent unintentional changes in function when the touchscreen panel is touched accidentally 1 To lock the unit at the selected sett...
Page 11: ...n Water level mark Running the unit with inadequate water may cause pump failure Connect a garden hose to the hose adapter securely Make sure hose adapter seal washer is evenly set inside the adapter Connect water supply to the garden hose and turn on water supply Water inside the tank will automatically refill once it reaches the Min Level Similarly the water supply to the tank will stop once the...
Page 12: ...ug the unit from the power outlet and fill the tank with water above the minimum level To turn off the alarm function and continue to use it in FAN mode turn off the unit and turn the unit on If COOL button is pressed again without filling the tank with water low water alarm will activate again COOLER LOCATION Place the cooler in front of an open door or window Ensure that there is adequate cross ...
Page 13: ...ction on SWING Automatic swing of louvers TIMER Timer function of 0 5 to 8 hours NOTE Under direct sunlight effective remote control range will be reduced REMOTE CONTROL 12 NOTE Batteries not included in the package Please insert two new AAA dry cell batteries for fully functional remote control ...
Page 14: ...creen panel to vary the speed of air flow depending upon your requirement LOW and HIGH speed will be indicated with incremental bars on the panel Press the COOL button to turn on the cooling function which will be indicated by lit up LED of the COOL button To turn off the unit press the COOL button to stop the cooling function then press SPEED button to reduce the speed to LOW and then the POWER b...
Page 15: ...RAINING THE WATER TANK Turn the power off and disconnect the unit from power supply Move the unit to a location where it can be drained and remove the drainage tube cap see parts description on page 7 Once the tank is empty refill with clean water and drain it again This should be repeated weekly to maintain the integrity of the unit and to remove particles filtered from the air Once the tank is c...
Page 16: ...e used to loosen mineral deposits Deep Cleaning Caution honeycomb assembly should be removed and serviced one at a time Rear Honeycomb Assembly Remove the screw holding the rear honeycomb cover in place Gently unsnap and remove the rear honeycomb cover Grab and pull out the rear honeycomb frame Remove screws from the honeycomb retainer cover Remove the honeycomb for inspection cleaning or replacem...
Page 17: ...ON Turn on COOL function from remote or control panel Low or no water in tank when COOL is selected Refill water tank Odour omission New Unit When the unit is used for the first time the Honeycomb cooling media will have an odour which will dissipate within a week of initial use Old Unit There may be an algae issue Replace the honeycomb cooling media Contact service centre Damaged Pump or Calcium ...
Page 18: ...e if needed Try to operate using the control panel Damaged PCB Try with remote control If the unit responds PCB board fasteners may be loose Contact service centre If neither remote control nor control panel works PCB board may be damaged Contact service centre PROBLEM POSSIBLE CAUSE SOLUTION 17 ...
Page 19: ...Frequency Wattage Water Tank Capacity Cooling Media Product Dimension Net Weight Current ELECTRICAL WIRING DIAGRAM TECHNICAL SPECIFICATIONS 220 240V 50Hz 270 Watts 30 Litre Honeycomb 546 L x 437 W x 1082 H mm 30 Kg 1 2 2 2 A 18 ...
Page 20: ... Limited The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representation or warranties with respect to this product Manufactured by AirTek International Corporation Limited ...