Honeywell BK-G1.6A Operating Instructions Manual Download Page 4

GB-4

D

GB

F

NL

I

SK

RUS

E

RO

SRB

BK-G..E, BK-G..ET, BK-G..ETB with index EI
Category  devices:

BK

Elster GmbH, Strotheweg 1

D-49504 Lotte, Germany

0044         II 3/1G IIB T4

TÜV 14 ATEX 143120 X

t

amb

 = t

gas

 = –20 °C ... +55 °C

Use as follows:
Category, internal: 3 (Zone 2), external: 1 (Zone 0).

Type of atmosphere: gases, hazes and vapours.

For the ambient and gas temperatures of the ATEX 

Zones, see illustration.

Category  devices:

BK

Elster GmbH, Strotheweg 1

D-49504 Lotte, Germany

13 ATEX 1389 X

II -/3 G IIA T1

Use as follows:
Category, internal: none, external: 3 (Zone 2).

Type of atmosphere: gases, hazes and vapours.

BK-G..B

BK

Elster GmbH, Strotheweg 1

D-49504 Lotte, Germany

TÜV 12 ATEX 098560 X

II -/2 G IIA T4

Use as follows:
Category, internal: none, external: 2 (Zone 1).

Type of atmosphere: gases, hazes and vapours.

BK-G..E with EI5

M ... 

Elster GmbH, Strotheweg 1

49504 Lotte, GERMANY

S/N

: ............ 

EI5.0x

0102

16ATEX1551X

tamb = tgas = –20 °C ... +55 °C

II 3Gic c IIA T1Gc

Use as follows:
Category: 3 (Zone 2).

Type of atmosphere: gases, hazes and vapours.

BK-G..ETe with EI6

EI6.0x

t b 

t m 

t g 

IP 

Valve Ve

18ATEX1678 X

tamb = tgas = –25 °C ... +55 °C

M ... 

0102

GPRS

II -/3 G ic c IIB T4 Gc

Use as follows:
Category, internal: none, external: 3 (Zone 2).

Type of atmosphere: gases, hazes and vapours.

Installation

 WARNING

Please observe the following to ensure that neither 
persons nor the gas meter are damaged during 
installation and operation:

–   Note the max. allowable operating pres-

sure p

max

 and measuring range Q

max

, see 

page 2 (Type label/Index plate).

–   Note the permitted ambient temperature t

m

 and 

gas temperature t

g

, see page 2 (Type label/

Index plate) or page 9 (Technical data).

–   The gas meters are certified for mechanical 

environments pursuant to Class M1 of Directive 

2004/22/EC. When installed, the meters must 

not be subject to permanent vibration such as 
that caused by machines in the vicinity. In case 
of doubt, vibration isolation must be provided. 
For gas meter versions BK..A, BK..E and BK..B, 
Class E2 for electromagnetic environments also 
applies.

–   The dangers of chemical reactions between 

gas meter parts and the chemical substances 
in the environment are to be discussed by the 
manufacturer and the operator and must be 
eliminated.

–   When installing the diaphragm gas meter BK with 

integrated valve, make sure that no dirt particles 
get into the meter and thus into the valve.

–   The yellow sealing sleeve protects the pressure 

test point on the gas meter. It may only be opened 
for connecting a pressure measuring line.

–   Use seals made from tested materials.  Elastomer 

seals or asbestos-free flat seals from Elster are 
recommended.

–   Only use the seals once.
–   For meters resistant to high temperatures, only 

use seals tested to be resistant to high tempera-
tures.

Summary of Contents for BK-G1.6A

Page 1: ...ified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts All technical changes are prohibited Only use OEM spare parts Changes to edition 07 17 The following chapters have been changed Checking the usage Commissioning Accessories Technical data Declarations of conformity ATEX legend Logistics Contents Operating instructions D GB GB 1 1...

Page 2: ...C A E B Mechanical index Chekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te TB TeB Temperature conversion mechanical electronic mechanical electronic temperature conversion and pressure correction electronic temperature conversion and pressure correction Part designations 1 3 5 7 6 2 4 1 Diaphragm gas meter BK 2 Index with index plate 3 Co...

Page 3: ...the index variant can be found at the bottom of the type label or on the index cover next to the serial number S N EI6 tm tg tb M 0102 15 ATEX 1550 X Further information can be found in the supplemen tary operating instructions of the relevant index Diaphragm gas meters with integrated valve DE 07 MI002 PTB001 S N 002545632734 class 1 5 NG 47001BM0443 DIN EN 1359 2007 BK G VALVE Vx M 0102 m3 Valve...

Page 4: ...serve the following to ensure that neither persons nor the gas meter are damaged during installation and operation Note the max allowable operating pres sure pmax and measuring range Qmax see page 2 Type label Index plate Note the permitted ambient temperature tm and gas temperature tg see page 2 Type label Index plate or page 9 Technical data The gas meters are certified for mechanical environmen...

Page 5: ...w arrow The gas meter must not be in contact with ma sonry or other parts Ensure that there is sufficient installation space Ensure unobstructed view of the index The seal faces on the screw unions must be clean and damage free Ensure that the seal is correctly seated Co axial meters The seal must be centred over the internal dia meter When using an elastomer seal always use a pressure ring shape ...

Page 6: ...e installation and tightness test are com plete see page 6 Tightness test protect the pressure test point against external access with the sealing sleeve and the seal Pressure test point on outlet connector optional BS4161 compliant pressure test nipple Use a 10 mm spanner to release tighten the test point screw The test nipple is secured to prevent it turning with the screw Opening the test nippl...

Page 7: ...lectrical circuits of pulse transmitters IN Z61 and IN Z64 are consid ered to be grounded at voltages 10 V if the plug connector housings are connected to the ground potential The intrinsically safe electrical circuits of pulse transmitters IN Z61 IN Z62 and IN Z65 are to be considered as non grounded BK G A with Absolute ENCODER index AE1 Z6 Interface description for gas meters with ENCODER index...

Page 8: ...g force and fully releases the gas supply If consumers of the customer are open pressure equalization cannot occur and the valve remains in the Released position and continues to release only the minimum gas flow rate of the bypass Closed The valve and the bypass are closed in the event of remote shut down All valve positions are kept when de energized Maintenance Removal Gas meters BK G1 6 to 25 ...

Page 9: ...e required error limits If no gas temperature tg is specified on the index plate the following applies tg tm The specified centre temperature tsp of the BK G E series and BK G B meters is not stated on the index plate but can be called up in the display using the menu Diaphragm gas meters BK with pressure test point Pressure test point 24 olive fitting to EN ISO 8434 1 L6 x M12 x 1 5 St Diaphragm ...

Page 10: ... F NL I SK RUS E RO SRB Declarations of conformity Scans of all valid Declarations of conformity see www docuthek com Elster Instromet Diaphragm gas meters BK G M BK G C BK G MT BK G CT without ATEX declaration ...

Page 11: ...GB 11 D GB Diaphragm gas meters BK G M BK G C BK G MT BK G CT with ATEX declaration ...

Page 12: ...GB 12 GB F NL I SK RUS E RO SRB Diaphragm gas meters BK G M BK G C BK G MT BK G CT with RFID passive tag and ATEX declaration ...

Page 13: ...GB 13 D GB Diaphragm gas meters BK G A BK G AT ...

Page 14: ... for Zone 2 c Constructional safety explosion protec tion type IIB IIA Explosion group for gases TX No intrinsic heating T1 Temperature class maximum allowable surface temperature 450 C T4 Temperature class maximum allowable surface temperature 135 C T6 Temperature class maximum allowable surface temperature 85 C Gc Equipment protection level for Zone 2 Ta Ambient temperature Logistics Transport D...

Reviews: