b.
Re-attach mating cable to Cannon connector (P4151/
P4161) on the back of the unit.
C.
ANTENNAS
(Refer to
FIGURE 2-8 KA 54 ANTENNA OUTLINE AND MOUNTING DRAWING
through
FIGURE 2-12 HONEYWELL GT 7003586 (SENSOR SYSTEMS TYPE S67-
2002-4 ANTENNA)
)
Refer to section 2.5.
E. IMPLEMENTING THE ANTENNA INSTALLATION
for
additional information and suggestions relating to installation of
antennas.
(1)
Removal
a.
Detach mating coaxial cable from antenna TNC connector.
b.
Remove the fasteners attaching the antenna to the air-
frame. (The number and pattern will vary depending on
antenna type, consult proper antenna mounting drawing
for details).
(2)
Re-installation
a.
Align antenna with panel mounting holes and secure with
fasteners. (The number and pattern will vary depending
on antenna type, consult proper antenna mounting draw-
ing for details).
b.
Re-attach mating coaxial cable to antenna TNC connec-
tor.
2.8
HONEYWELL MAINTENANCE RECOMMENDATIONS
The KRA 405B Radar Altimeter System has been designed for “on-condition”
maintenance. For details relating to “on condition” maintenance, refer
to Honeywell Service Memo SM #292, P/N 600-08292-XXXX.