(cont...)
Infrared (IR) Emitter Port [8]
– This will accept a standard IR emitter with a 3.5mm 2-cond. mini plug.
This jack is provided for infrared control of the source component. It is a routed output that will only emit
commands from a Volume Control Module in a zone that has selected that source. Some components
have a 2-cond. IR input jack on the back. It is recommended that this direct connection be used.
CAUTION: Do not confuse a serial data port connection with an infrared port.
12v DC Trigger [12]
- This is a 12v DC output that turns on when that source is selected. The output
can be used to trigger a relay for power control of the source component.
CAUTION: Do not hook up devices to the Trigger that will exceed 50mA of current draw.
Audio Input [13]
- For connection to source component
Loop Out [14]
- To loop the same audio component source into a home theater receiver or an amplifier
A-BUS® is a Registered Trademark of LeisureTech Electronics Pty Ltd Sydney, Australia.
International Patent Pending LeisureTech Electronics Pty Ltd Sydney, Australia
IMPORTANT NOTE
- LTE reserves the right at any time and without prior notice to
update, amend, vary or alter the instructions and specifications in this manual.
LTEHWABX75IM Rev: 1.3 14/02/07
AUDZBX75 A-BUS Source Input Module
Specifications
Socket
Brown
Brown & White
Blue & White
Green & White
Green
Orange & White
Orange
Blue
8 7
5
3
1
6
4
2
8
7
6
5
4
3
2
1
Pin Signal
+24 Vdc
Ground
Right Ch. Ground
Left Ch. Ground
Status
IR
Right Channel
Left Channel
A-BUS Wiring Color Code (T568A)
Input Module
Inputs
Outputs
AUDZBX75
Audio
Audio
IR
Trigger
A-BUS
A-BUS Source Input Module
1 x Stereo RCA Pair
1 x Stereo RCA Pair Loop Thru
1 x 3.5mm mini phono
1 x 3.5mm mini phono 12vdc +V Center 50mA
1 x Cat-5 110 Punchdown