Section 3 - Installing the Control
3-21
To install the VIP module, perform the following steps:
Step Action
1
Mount the module in the control cabinet if
space is available or, if this is not possible, on
the side of the cabinet or adjacent to it.
If you mount the VIP Module inside the
control cabinet,
attach it to the cabinet’s
interior surface with 2-faced adhesive tape.
You may leave the module’s cover off if it is
mounted within the cabinet.
If you mount the module outside the
cabinet,
use the screw holes at the rear to
mount horizontally or vertically (2-faced
adhesive tape may be used, if preferred).
2
Affix the 4285/4286 connections
label
(supplied separately) to the inside of the VIP
Module’s cover, if the cover is used.
Otherwise, affix the label to the inside of the
control cabinet’s
door.
3
Make 12V (+) and (–) and data-in and data-
out connections from the VIP Module to the
control, using the connector cable supplied
with the VIP Module. These are the same
connections as for remote keypads.
Step Action
Connect the module to the phone line as
shown below. See
Figure 3-27.
4285/4286 Terminal
Connects to direct
connect cord:
1.
Phone In (Tip)
green wire
2.
Phone In (Ring)
red wire
3.
Phone Out (Tip)
brown wire
4.
Phone Out (Ring)
gray wire
5.
No Connection
6.
Audio Out 1
∗
Speaker
7.
Audio Out 1
∗
Speaker
Supported by the 4286 only
4
Use an RJ31X Jack with the phone cable
supplied with the control to make connections
to the VIP module. Make connections exactly
as shown in
Figure 3-27
.
This is essential,
even if the system is not connected to a
central station. The 4285/4286 will not
function if this is not done.
•
If touch-tones are not present following phone
access to the security system
via an on-
premises phone
, try reversing the pair of
wires connected to terminals 3 and 4 on the
4285/4286.
•
If the phone plug is disconnected from the
control, the premise’s phones will not operate.
YELLOW
NO CONNECTION
RED
BLACK
GREEN
TO CONTROL PANEL
KEYPAD CONNECTIONS
KEYED
HEADER
12
3
4
5
6
7
NO
CONNECTION
4286 VIP MODULE
ANSWERING
MACHINE
PREMISES
ANSWERING
MACHINE AND
PHONES
TIP
RING
RJ31X
JACK
TIP
RING
INCOMING TELCO LINE
CALLER ID
UNIT
IMPORTANT NOTE FOR EXISTING INSTALLATIONS:
EXISTING WIRES CONNECTED TO THE “HANDSET”
TERMINALS ON CONTROL MUST BE MOVED FROM
THERE TO TERMINALS 3 AND 4 ON THE 4286.
U.S. PATENT No. 4791658
THIS DEVICE COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION No. AC3USA-74659-KX-N
RINGER EQUIVALENCE: 1.0B
FOR COMPLETE INFORMATION, SEE INSTALLATION
INSTRUCTIONS N6431-3 ACCOMPANYING 4286 VIP
MODULE
GREY
BROWN
GREEN
RED
EARTH
GROUND
TIP RING TIP RING
4500
THERMOSTAT
GREEN
YELLOW
HANDSET INCOMING
TELCO LINE
NOTE:
4286 DEVICE
ADDRESS IS
FACTORY SET
TO “4”
SEE SPEAKER NOTE
SPEAKER NOTE:
IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY.
IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS
AND
CONNECT IN SERIES.
SPEAKER
VOLUME
CONTROL
4286_wiring-002-V1
Figure 3-27: VIP Module Connections
Summary of Contents for ADEMCO VISTA-40
Page 1: ...N7001V5 5 04 Rev A 0 0 2 2 9 9 6 67 7 3DUWLWLRQHG 6HFXULW 6 VWHP QVWDOODWLRQ DQG 6HWXS XLGH ...
Page 2: ...ii ...
Page 10: ...VISTA 40 Installation and Setup Guide 2 2 ...
Page 38: ...VISTA 40 Installation and Setup Guide 3 28 ...
Page 46: ...VISTA 40 Installation and Setup Guide 4 8 ...
Page 62: ...VISTA 40 Installation and Setup Guide 6 4 ...
Page 64: ...VISTA 40 Installation and Setup Guide 7 2 ...
Page 78: ...VISTA 40 Installation and Setup Guide B 2 ...
Page 80: ...VISTA 40 Installation and Setup Guide C 2 ...
Page 82: ...VISTA 40 Installation and Setup Guide D 2 ...
Page 89: ...NOTES ...
Page 90: ...NOTES ...
Page 91: ...NOTES ...
Page 92: ...NOTES ...
Page 93: ...NOTES ...
Page 94: ...NOTES ...
Page 95: ...NOTES ...