352*5$00,1*)250
Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
Entries shown in dashed boxes indicate partition entries for VISTA-20P only (not applicable for VISTA-15P).
Field Function Data Entries Programmable Values
SYSTEM SETUP (
✱
20–
✱
29)
∗
20
INSTALLER CODE
| | |
[4112]
4 digits, 0–9
✱
21
QUICK ARM ENABLE
[0,0]
Part. 1 Part.2
0 = no; 1 = yes
✱
22
RF JAM OPTION
[0]
0 = no RF Jam detection; 1 = send RF Jam report
UL: must be 1 if wireless devices are used
✱
23
FORCED BYPASS
[0,0]
Part. 1 Part. 2
0 = none UL: must be “0”
1 = bypass open zones
∗
24
RF HOUSE ID CODE
| | |
Part. 1 Part. 2 Common
00 = disable all wireless keypad usage
01–31 = using 5827, 5827BD or 5804BD keypad
[00,00,00]
✱
26
CHIME BY ZONE
[0]
0 = no; 1 = yes (select zones to chime on zone list 3,
using *81 Menu mode)
✱
27
X–10 HOUSE CODE
[0]
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G,
7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N,
#14 = O, #15 = P UL: not for fire or UL installations
✱
28
ACCESS CODE FOR
4285/4286 PHONE MODULE
| [00]
(Partition 1 only)
00 = disable; 1st digit: enter 1–9; 2nd digit: enter # + 11
for "
✱
", or # + 12 for "#".
UL: must be “00” for UL Commercial Burg. installations
✱
29
LONG RANGE RADIO OUTPUT
[0]
0 = disable; 1 = enable
ZONE SOUNDS AND TIMING (
✱
31 –
✱
39)
✱
31
ONE AUDIBLE ALARM PER ZONE
[0]
0 = no UL: must be “0”; 1 = yes
✱
32
FIRE ALARM SOUNDER TIMEOUT
[0]
0 = sounder stops at timeout;
1 = no sounder timeout UL: must be “1” for fire install.
✱
33
ALARM SOUNDER TIMEOUT
[1]
0 = none; 1 = 4 min; 2 = 8 min; 3 =12 min;
4 = 16 min; UL: minimum “1” (4 min.)
✱
34
EXIT DELAY
| | [70,70]
Part. 1
Part. 2
00–99 = seconds of exit delay time for each partition
Common zones use same delay as partition 1.
✱
35
ENTRY DELAY #1 (zone type 01)
| | [30,30]
Part. 1
Part. 2
00–99 = seconds of entry delay #1 time for each
partition; UL: 45 seconds max.
Common zones use same delay as partition 1.
✱
36
ENTRY DELAY #2 (zone type 02)
| | [60,60]
Part. 1
Part. 2
00–99 = entry delay #2 time for each partition;
UL: 60 seconds max.
Common zones use same delay as partition 1.
∗
37
AUDIBLE EXIT WARNING
[1,1]
Part. 1
Part. 2
0 = no; 1 = yes
✱
38
CONFIRMATION OF ARMING DING
[0,0]
Part. 1
Part. 2
0 = no; 1 = yes (wired keypads and RF)
2 = yes, RF only
✱
39
POWER UP IN PREVIOUS STATE
[1]
0 = no; 1 = yes UL: must be “1”
DIALER PROGRAMMING (
✱
40 –
✱
42)
Enter the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '
✱
'; #+12 for '#'; #+13 for a 2-second pause. If fewer than the
maximum digits entered, exit the field by pressing [
✶
] and next desired field number.
∗
40
PABX ACCESS CODE
| | | | |
Enter up to 6 digits. To clear entries from field, press
✱
40
✱
.
∗
41
PRIMARY PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. To clear entries, press
✱
41
✱
.
∗
42
SECOND PHONE No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. To clear entries, press
✱
42
✱
.