Honeywell ADEMCO 745 3 Series Installation And Setup Manual Download Page 1

N9080-1V2  3/04 

 

ADEMCO 745x3 

Voice Siren Driver

 

INSTALLATION AND SETUP GUIDE 

FEATURES 

• 

Listed for:  UL 985 Household Fire, UL 1023 Household 
Burglary, UL 609 Commercial Burglary.   

• 

Generates voice output in English, Spanish, and French.   

• 

Separate messages for FIRE and BURGLARY conditions.   

• 

Separate siren sounds for FIRE and BURGLARY 
conditions.   

• 

Terminal strip for secure connection to control panel.   

• 

Selectable input level (High/Low) for FIRE/BURGLARY 
inputs.   

• 

Supervision feature for speaker and speaker wiring.   

• 

Compatible with control panels within parameters 
stated.   

• 

Sounder options for bell ringback/bell test.   

• 

Compatible with 8 - 32 ohm speakers.   

• 

Operates on 12 - 16V DC.   

• 

Small compact size for easy installation using double-
sided tape provided – measures only 4” x 2-5/8” x 1-1/4”.   

OUTPUT SELECTION 

The voice driver can be programmed for the desired alarm 
output on burglary and fire by means of jumpers JP1 
through JP4, as indicated in Table 1.  See Figure 1 for 
location of jumpers.   

Table 1.  Output Selection 

JUMPERS 

OUTPUT 

JP1 JP2 JP3  JP4 FIRE BURG 

– – –  – 

ENG 

ENG 

X –  –  – 

ENG/FREN 

ENG/FREN 

– X –  – 

ENG/SPAN 

ENG/SPAN 

X X  –  – 

E N G /S P A N /F R E N   ENG/SPAN/FREN 

– – X  – 

FREN 

FREN 

X – X  – 

SPAN 

SPAN 

– X X  – 

SIREN 

SIREN 

X X X  – 

ENG 

SIREN 

– – –  X 

ENG/FREN 

SIREN 

– – X X 

ENG/SPAN 

SIREN 

– X –  X 

E N G /S P A N /F R E N   SIREN 

– X X  X 

SIREN 

ENG 

X – X  X 

SIREN 

FREN 

X X  –  X 

SIREN 

SPAN 

X –  –  X 

SIREN 

ENG/SPAN/FREN 

X X X  X 

ENG 

ENG 

X = CUT, – = INTACT  

Bell Test/Ringback Options (JP5) 

If jumper JP5 is kept intact, the siren driver will generate a 
steady sound for bell test and bell ringback conditions.   

If the jumper is cut, a warbled sound will be generated for 
bell test/ringback conditions.   

NOTE:  If this mode is selected, a fire signal will 
momentarily generate a warbled siren sound for the initial 
portion of the siren sound and then revert to the normal 
siren sound and voice message.  

Jumper JP5 shall be cut in 

UL Listed systems

.   

Burglary Signal Polarity (JP6) 

Intact = High (12V+), cut = Low (0V) 

The burglary message may be activated by either a steady 
logic high or steady logic low, as provided by the control 
panel (refer to the control panel’s instructions).   

When jumper JP6 is intact, activation is by a logic high 
(12V+) at terminal 2.  Cut jumper JP6 for activation by a 
logic low (0V).   

Note that a pulsing high or low (pulse width 0.25 to 1.75 
seconds, that is provided by some panels) connected to the 
Burglary/Fire input (terminal 2) will be interpreted as a 
Fire condition and will produce the fire message.   

Fire Signal Polarity (JP7) 

Intact = High (12V+), cut = Low (0V).   

As in the case of Burglary signal polarity, the fire message 
may be activated by either a logic high or logic low, but at 
terminal 3.  When jumper JP7 is intact, activation is by a 
logic high (12V+).  Cut jumper JP7 for activation by a logic 
low (0V).   

Burglary Messages: 

ENGLISH: 

YOU HAVE VIOLATED THE PROTECTED AREA…THE 
POLICE HAVE BEEN CALLED…LEAVE IMMEDIATELY! 

SPANISH: 

USTED HA VIOLADO UNA AREA PROTEGIDA…LA 
POLICIA HA SIDO LLAMADA   SALGA INMEDIATAMENTE! 

FRENCH: 

VOUS AVEZ PENETRE UN LIEU SURVEILLE…LA POLICE 
A ETE AVERTI…EVAQUEZ IMMEDIATEMENT! 

Burglary Alarm Sequence:

   

Warble Siren sound, Burglary Voice Message (repeated 3 
times), 15-second Warble Siren Sound.   

Sequence will repeat until the Burglary output condition is 
terminated.   

 

Fire Messages: 

ENGLISH:  

FIRE…LEAVE IMMEDIATELY! 

SPANISH:  

FUEGO…SALGA INMEDIATAMENTE!

 

FRENCH:  

AU FEU!…EVAQUEZ IMMEDIATEMENT! 

Fire Alarm Sequence: 

Steady Siren Sound, Fire Voice Message repeated 3 times 
on a single language output, followed by 15 seconds of 
Steady Siren Sound.  Sequence will repeat until the Fire 
output condition is terminated.   

WIRING CONNECTIONS 

Wiring connections to the terminals are as follows:  Refer to 
Figure 1 (and Table 2 for Honeywell products).   

1 SUPV:  SPEAKER/WIRING SUPERVISION (OPTIONAL). 

For supervision of speaker and associated wiring, connect to 
the high (+) side of a 24-hour zone that is activated by a 
short.  Removing the speaker or shorting either speaker 
terminal to ground where operation is affected will appear 
as a short on the zone.  Note that in series-connected 

Reviews: