Honeywell ADEMCO 6150V Installation Manual Download Page 1

K0022V2 12/01  Rev. B

 

ADEMCO 6150V & 6160V 

Voice Remote Keypads

 

INSTALLATION AND SETUP GUIDE 

GENERAL INFORMATION

 

The ADEMCO 6150V and ADEMCO 6160V are addressable 
remote keypads designed for use with ADEMCO control 
panels and provide the following features:   

• 

Backlit Display 

• 

Voice Chime 

• 

Programmable Function 
Keys 

• 

Voice Status 

• 

Message Center 

• 

Built-in Sounder 

 

Notes:   

• 

When used with the ADEMCO VISTA-15P/VISTA-
20P control panels, address 16 must be assigned to 
the first keypad.  Additional keypads must be 
assigned to address 17 – 23.  Refer to Setting The 
Keypad Options.  

 

• 

Keypad keys are continuously backlit for convenience.   

• 

Permanent display backlighting is an option on some 
controls (refer to the control panel’s instructions for 
details).  

• 

Voice Chime should only be enabled when used with 
control panels that support the "chime by zone" mode 
(e.g., VISTA-15P/VISTA-20P).  This mode must be 
enabled at the control panel.  Refer to the control panel's 
installation and setup guide for information on how to 
program the chime mode.   

• 

Use only zone descriptors supported by this 
keypad.  If using zone descriptors not supported 
by this keypad, you must turn voice status and 
voice chime off.  Table 1 is a list of applicable zone 
descriptors and index entries.  

Refer to

 

the control 

panel’s installation and setup guide for information 
about how to program zone descriptors.   

KEYPAD DISPLAYS AND LEDS 

The keypads have the following display features: 

Model

 

Fixed 
Word 
Display

 

2-Line 
Alpha 
Display

 

2-Digit 
Zone 
Identifier

 

Custom 
Zone 
Descriptors

 

6150V

 

X   X   

6160V

 

 X 

  X 

The following table identifies the keypad’s LEDs and 
associated functions: 

LED

 

Function

 

ARMED

 

Lights red when the system is armed in any mode.

 

READY

 

Lights green when the system is "ready" to be 
armed.

 

MESSAGE

 

Flashes red when message waiting or lights red 
(steady) when in record mode.

 

PROGRAMMABLE FUNCTION KEYS 

The keypad's programmable function keys [A, B, C] are 
normally used for keypad panic functions, but they can be 
programmed for other special functions instead.  If they are 
programmed for other special functions, the associated 
keypad key pairs still provide the respective panic alarm (if 
programmed).  Refer to the control panel’s Installation & 
Setup Guide for details.  

 

Function 

Keys 

Equivalent Key Pairs 

A

 

[1] and [*]

 

B

 

[*] and [#]

 

C

 

[3] and [#]

 

D

 

NONE 

 

 

• 

Function  keys  must  be  held  down  for  at 
least 2 seconds to activate the programmed 
function. 

 

• 

If functions other than panics are assigned 
to the programmable function keys, 
programmed panics must be initiated by 
pressing the programmed key pair.

 

FUNCTION KEY LABELS

 

A set of adhesive-backed labels with some typical function 
symbols (i.e., fire, police, personal emergency, etc.) is 
provided.  These labels can be placed on or next to the keys 
to identify each key's function for the end user (as 
determined by the capability and programming of the 
control panel; refer to the installation and setup guide for 
the control panel). 

6160V

-001-V1

MOUNTING RELEASE SNAPS

(Remove case back by pushing up the 2 "snaps" along

the keypad's bottom edge and pulling the case apart.)

1

OFF

4

MAX

7

INSTANT

READY

2

AWAY

5

TEST

8

CODE

0

3

STAY

6

BYPASS

9

CHIME

#

MESSAGE

MIC

ARMED

READY

RECORD

VOLUME

PLAY

STATUS

FUNCTION

VOICE

SIDE

VIEW

D

C

B

A

 

WIRING AND INSTALLATION

 

Keypads can be surface mounted using drywall anchors or 
to a single- or double-gang electrical box.  
1. 

Remove the case back

 by pushing up the two "snaps" 

along the keypad’s bottom edge and pulling the case 
apart.  See diagram above. 

2. 

Route wiring from the control panel

 through the 

opening in the case back. 

3. 

Mount the case back

 to a wall or electrical box.  

4. 

Wire directly from the keypad’s terminal block 

to 

the terminal block on the control board. (See Wiring 
Table that follows.)  

Wiring Table (All Keypads) 

Keypad 

Control Panel 

Wire Color 

°

 G

 

Data In

 

Green

 

 

– Aux Pwr (GND)

 

Black

 

+

 

+ Aux. Pwr

 

Red

 

±

 Y

 

Data Out

 

Yellow

 

5. 

Re-attach the keypad 

to the case back. 

6. 

Remove clear protective film from LEDs (6160V 
only).

 

Reviews: