background image

 

— 2 —

 

— 3 —

 

3.

 

If 

concealed

 wiring is to be used,

 feed the wires through the concealed wiring entry hole at 

one corner of the plate (

surface

 wiring is mentioned in Step 5 below). 

4. Install the mounting plate,

 with its case holding posts pointing up (in this example), in the 

location selected as described in the control unit’s installation instructions. Use the flat-head 
screws supplied.  

5. If 

concealed

 wiring is to be used,

 feed it through the slot in the case back but do not connect 

to the terminal block yet. 

Surface

 wiring

 should enter via the thin "breakout" area provided in 

the case wall. 

6.  Attach the case back 

to the mounting plate by sliding the keyhole slots in the case back down 

onto the mounting plate’s hooks. The locking tab will click as the case back locks in place. 

7  Set the DIP switch 

(after the control has enrolled the transmitter’s input IDs) for the desired 

primary loop characteristics, as described in the table below.   

 

P R I M A R Y   L O O P   O P T I O N S   T A B L E 

SWITCH 

 

D I P   S W I T C H   P O S I T I O N 

SETTING 1 

ON 

REPEATING 

TRANSMISSION  

(every 4 sec.)  

UPON PRIMARY  

LOOP FAULT 

Use for high-priority  

alarm, such as fire.

 

NORMALLY  

OPEN CIRCUIT 

PRIMARY LOOP 

SLOW 

PRIMARY LOOP 

RESPONSE 

(Approx. 200mSec 

Normally Closed 
Response Time)

 

3 MINUTE, ALL LOOP 

TRANSMISSION INHIBIT 

AFTER RESTORE OF 

PRIMARY LOOP 

See Note c. 

This affects the Aux. loops as 

well.  Use on frequently used 

doors, etc. to conserve battery.

 

OFF

 

SINGLE 

TRANSMISSION  

PER PRIMARY 

LOOP  

CHANGE-OF-

STATE

 

NORMALLY  

CLOSED 

CIRCUIT 

PRIMARY 

LOOP 

FAST 

PRIMARY LOOP 

RESPONSE 

(Approx. 5mSec 

Normally Closed 
Response Time)

 

NO  

TRANSMISSION  

INHIBIT 

 

Notes

a. While the transmitter is being enrolled by the control, all DIP switch positions should 

be OFF. 

 

b. Except in the case of the position 4 ON setting, the Auxiliary loops are not affected by 

the DIP switch settings. 

 c. 

For UL installations with fire zones, the position 4 ON setting must not be used. 

 

WIRING CONNECTIONS 

With the battery still not inserted, connect the loop wiring to the unit’s terminals (see Diagram 2).  

Note

:  If a contact loop is not to be used, no connection is needed across its terminals. 

 

BATTERY INSTALLATION/REPLACEMENT 

1.  Remove the transmitter’s cover 

(if not already off) as described in Mounting Step 1. 

2. Observe correct polarity and insert the battery

 provided into the battery holder (see 

Diagram 2). 

Take care not to bend the antenna.

 

Note

:

 Replace 

battery 

only

 with: Duracelll DL123A, Sanyo CR123A,  

Panasonic CR123A, ADEMCO 466, or Varta CR123A. 

CAUTION:

  Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above 

212°F (100°C), or incinerate. Dispose of used batteries promptly. Keep away 
from children. 

3.  To replace the cover, 

engage the hooks along one edge and snap shut. 

 

SPECIFICATIONS 

Dimensions 

1-9/16"W x 3-1/2"H x 1-3/16"D (40mm x 89mm x 30mm) 

Battery 

3V Lithium (see 

BATTERY INSTALLATION/REPLACEMENT).

 

TO THE INSTALLER 

Regular maintenance and inspection (at least annually) by the installer and frequent testing by 
the user are vital to continuous satisfactory operation of any alarm system. 
The installer should assume the responsibility of developing and offering a regular maintenance 
program to the user, as well as acquainting the user with the proper operation and limitations of 
the alarm system and its component parts. Recommendations must be included for a specific 
program of frequent testing (at least weekly) to ensure the system’s operation at all times. 

REFER TO THE CONTROL'S

 

INSTALLATION INSTRUCTIONS FOR THE 

RECEIVER/CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS ON 
LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 

 

CASE

HOLDING

POSTS (2)

PLATE

MOUNTING

HOLES (2)

ALIGNMENT GUIDE STRIP
(NOT USED IN THIS APPLICATION.
BREAK AWAY, IF DESIRED.)

CONCEALED WIRING
ENTRY HOLE

CASE LOCKING TAB

 

 

Diagram 1: MOUNTING PLATE

 

 
 

 

 

Diagram 2: 5817 (SHOWN WITH COVER REMOVED) 