SPECIFICATIONS 

Transmission Frequency:  

345MHz 

Unit Dimensions:  

2-1/4”W (57mm) x  1-1/2” H 

(38mm) x 0.5”D (12.7mm) 

+ POS. end 
must face down

+ POS. end 
must face down

 

INSTALLING THE BATTERIES 

Battery:  Use only Duracell DL2025 or ADEMCO 

supplied batteries. 

Battery Access: 

1. Put the alarm system into the TEST mode by 

entering your user code plus the number 5 
(TEST) on the keypad. While the alarm system is 
in the TEST mode, the keypad will beep every 30 
seconds. 

 

2. Remove case back by inserting the blade of a 

small screwdriver into the seam around the case 
and prying the case open. 

3.  Remove the existing batteries by prying them out 

with a small screwdriver. 

4.  Push new batteries into case back locations (see 

diagram).  The + POS side must face down. 

5.  Close by snapping case front and back together. 

6. Exit the alarm system TEST mode by entering 

your user code plus the number 1 (OFF). 

Important Note: 

Do not remove Printed Circuit 

Board. 

 

Figure 2. Battery tabs shown 

 

Blue

Red

 

Figure 3. 5804 shown open, 

buttons facing down. 

 

FCC STATEMENT 

FCC ID: CFS8DL5804   

    CANADA: 1748101619 5 3 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference.  (2) This device must accept any interference received, 
including interference that may cause undesired operation. 

 

FOR WARRANTY INFORMATION, AND FOR DETAILS REGARDING THE LIMITATIONS OF THE ENTIRE ALARM 
SYSTEM, REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH WHICH THIS 
DEVICE IS USED. 

165 Eileen Way, Syosset, New York 11791

Copyright © 2004 Honeywell International Inc.

www.honeywell.com/security

 

 

ÊN7674V2pŠ 

N7674V2  5/04  Rev. A

 

WWW.DIYALARMFORUM.COM