Honeywell ADEMCO 5800RL Installation Instructions Download Page 2

 

 

HOUSE 

ID

 

DIP SWITCH POSITIONS 

HOUSE 

ID

 

DIP SWITCH POSITIONS

 

16 

ON

 

ON 

17 

ON 

ON 

ON 

18 

ON 

ON 

ON 

ON 

19 

ON 

ON 

ON 

ON 

20 

ON 

ON 

ON 

ON 

21 

ON 

ON 

ON 

ON 

ON 

22 

ON 

ON 

ON 

ON 

ON 

ON 

23 

ON 

ON 

ON 

ON 

ON 

24 

ON 

ON 

ON 

ON 

25 

ON 

ON 

ON 

10 

ON 

ON 

26 

ON 

ON 

ON 

11 

ON 

ON 

ON 

27 

ON 

ON 

ON 

ON 

12 

ON 

ON 

28 

ON 

ON 

ON 

13 

ON 

ON 

ON 

29 

ON 

ON 

ON 

ON 

14 

ON 

ON 

ON 

30 

ON 

ON 

ON 

ON 

15 

ON 

ON 

ON 

ON 

31 

ON 

ON 

ON 

ON 

ON 

“ – “ indicates “OFF” 

 

2

3

4

5

6

1

2-6 SETS HOUSE ID

SW-1

NOT USED

5800RL DIP Switch

5800RF-003-V0

OFF POSITION

INDICATOR

SV6

7L

 

Figure 4.  DIP Switch Settings 

 

RELAY and LED Operation

 

The 5800RL contains two relays (Figure 2) (SPDT, rated 2A. 
28VAC/VDC)  that  may  be  used  to  activate  remote  sounders 
and/or  remote  arm/disarm  indicators.  There  are  three  LEDs 
(green,  yellow,  red)  located  above  the  DIP  switch  and  one 
LED (red) located approximately in the center of the pc board. 
The LEDs located above the DIP switch, indicate power and 
relay activity. Refer to Figure 2 on the previous page. The RF 
Interference LED monitors local radio frequency interference. 
If  this  LED  is  continuously  lit,  the  5800RL  should  be 
relocated.  

 

Relay 

LED 

Activates Upon… 

Yellow 

Alarm conditions as follows: 
Steady  ON  =  burglary  alarm  (NO  contact 
connects to COM) 
Temporal ON = fire alarm (NO contact connects 
temporal to COM) 
OFF = no alarms present (NC contact connects 
to COM) 

Red 

System armed/disarmed as follows: 
ON = system armed Away, Stay, or Instant (NO 
contact connect to COM) 
OFF = system disarmed (NC contact connects to 
COM) 

N/A 

Green 

Normally  on  (lighted)  when  power  is  applied. 
Flickering indicates RF is being processed. 

N/A 

RF 

Inter-

ference 

Lights when RF activity is present. 
If this LED is continuously lit, relocate the 
5800RL module. 

 

 

SPECIFICATIONS 

Dimensions: 

2-3/4”W x 4-15/16”H x 1-1/16”D

 

(70mm x 125mm x 27mm) 

Voltage:   

12VDC 100mA   

or 

9VAC, 15VA (use ADEMCO 1332 or equivalent) 

Current:   

100mA 

Relay:

  

Two relays, each with choice of normally open (NO) 

 

or normally closed (NC) operation. 

Operating Temperature:  

0 - 50°C / 32 - 122°F 

 

Federal Communications Commission (FCC) Part 15 

The user shall not make any changes or modifications to the equipment unless 
authorized by the Installation Instructions or User's Manual.  Unauthorized 
changes or modifications could void the user's authority to operate the 
equipment. 

CLASS B DIGITAL DEVICE STATEMENT 

This equipment has been tested to FCC requirements and has been found 
acceptable for use. The FCC requires the following statement for your 
information: 

 

This equipment generates and uses radio frequency energy and if not installed 
and used properly, that is, in strict accordance with the manufacturer's 
instructions, may cause interference to radio and television reception. It has 
been type tested and found to comply with the limits for a Class B computing 
device in accordance with the specifications in Part 15 of FCC Rules, which are 
designed to provide reasonable protection against such interference in a 
residential installation. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause interference to 
radio or television reception, which can be determined by turning the equipment 
off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures: 

 

•   If using an indoor antenna, have a quality outdoor antenna installed. 
•   Reorient the receiving antenna until interference is reduced or eliminated. 
•   Move the radio or television receiver away from the receiver/control. 
•   Move the antenna leads away from any wire runs to the receiver/control. 
•   Plug the receiver/control into a different outlet so that it and the radio or 

television receiver are on different branch circuits. 

•   Consult the dealer or an experienced radio/TV technician for help. 

 

INDUSTRY CANADA CLASS B STATEMENT 

This Class B digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du 
Canada. 

 

FCC/IC STATEMENT  

This  device  complies  with  Part  15  of  the  FCC  rules  and  RSS  210  of  Industry 
Canada.  Operation  is  subject  to  the  following  two  conditions:  (1)  This  device 
may  not  cause  harmful  interference,  and  (2)  This  device  must  accept  any 
interference  received,  including  interference  that  may  cause  undesired 
operation. 

Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 
des Industries Canada. Son fonctionnement est soumis aux conditions 
suivantes: (1) Cet appareil ne doit pas causer d' interférences nuisibles. (2) Cet 
appareil doit accepter toute interférence reçue y compris les interférences 
causant une réception indésirable. 

 

 

 
 
 
 

ÊK37906Š 

K3790  6/07  Rev. C

 

2 Corporate Center Drive, Melville, NY 11747

Copyright © 2007 Honeywell International Inc.

www.honeywell.com/security

 

 