In Case of Difficulty 

Check that the COM port you are using matches the COM 
port selected in the SETUP screen. 
A null modem adapter (not supplied) may be required to 

match the outputs of your computer’s serial port to the 
4100SM.  To determine if this is necessary, proceed as 

follows: 
1.

 

Connect the 4100SM to the control panel and to your 

PC as described previously in this document.  Do not 
attach a null modem adapter. 

2.

 

Connect a DC voltmeter, set to a 15-volt (or higher) 
range, across the black wire on 4100SM terminal 7(–), 

and the wire on terminal 3(+).  No voltage should be 
seen at this time. If a voltage is found, check the 

connections between the control and the 4100SM. 

3.

 

Go to the COMM screen after selecting DIRECT WIRE 
and hit the [ENTER] key two times until the 

REQUESTING SESSION message appears. At this 
time, the meter reading should jump to approximately 

12 volts for few seconds and then return to zero. If this 

does not occur, there is a possibility that the transmit 
and receive pins on the computer are reversed. Insert a 

Null Modem adapter (not supplied) and try again. 

SPECIFICATIONS 

Physical 

4" W x 2-3/4" H x 3/4" D (102mm x 70mm x 19mm) 

approximately 

Electrical

 

 

Input Power:  12VDC, 25mA from control's keypad 

power (red wire) connection 

RS-232 Interface: 

DB25 female with DCE output 

 

 

 

WARRANTY INFORMATION 

 

For the l

a

te

s

t w

a

rr

a

nty inform

a

tion, ple

as

e go to: 

 

www.honeywell.com/

s

ec

u

rity/h

s

c/re

s

o

u

rce

s

/w

a

 

 

 

 
 
 
 
 

 

2 Corporate Center Drive, Suite 100 

P.O. Box 9040, Melville, NY  11747 

Copyright © 2015 Honeywell International Inc. 

 

www.honeywell.com/security 

 

Summary of Contents for ADEMCO 4100SM

Page 1: ... a header on the control panel s circuit board via the supplied 4142TR voltage trigger cable As shown in Figures 1 and 2 terminals 3 6 7 and 8 on the 4100SM are used The three colored terminals red blue and white must be left uncut for direct wire downloading applications Most IBM compatible PCs have two RS 232 serial ports COM1 and COM2 You must decide which serial port you want to use and then d...

Page 2: ...erify that the default message typically DISARMED READY TO ARM is displayed 3 Start up the downloading software on your PC and verify that the main menu is displayed 4 Make sure that the downloading software is configured to operate using the serial port COM1 or COM2 that you selected earlier If you have an internal modem the serial port must be changed every time you change from modem to direct w...

Page 3: ...not used not used TXD not used DTR BLUE WHITE To TB11 Aux Power 25mA current draw To TB12 Aux Power 3M Cable Supplied with 4100SM SERIAL PRINTER SET FOR 8 DATA BITS EVEN PARITY STOP BIT 300 1200 BAUD 4100SM JUMPERS CUT TO SET RESPECTIVE SIGNAL FLOATING COLOR FUNCTION PIN RED BLUE WHITE CD CTS DSR 8 5 6 RED 4100SM 012 V2 8 7 USE GENDER CHANGER NOT SUPPLIED WITH 4100SM IF PRINTER HAS DB25 MALE CONNE...

Page 4: ...and the 4100SM 3 Go to the COMM screen after selecting DIRECT WIRE and hit the ENTER key two times until the REQUESTING SESSION message appears At this time the meter reading should jump to approximately 12 volts for few seconds and then return to zero If this does not occur there is a possibility that the transmit and receive pins on the computer are reversed Insert a Null Modem adapter not suppl...

Reviews: