background image

3 - 1

3

Bluetooth Module Programming Bar Codes

Introduction

Bar codes in this section are designed to be read by a ring scanner or ring imager connected to the Bluetooth Ring Scanner 
module.

This section contains programming bar codes to be used when programming the Bluetooth Ring Scanner module only.  The bar 
codes were created using Code 128 ASCII.  An asterisk (*) next to an option indicates the default setting.  Honeywell scanners 
and imagers are setup to read Code 128 bar codes by default.

The ring scanner, that is a part of the Bluetooth Ring Scanner product, has an SE955 scan engine.  Use 

1D Laser Scanner 

Programming Bar Codes

 (page 4-1) to program the ring scanner engine parameters.

The ring imager, that is a part of the Bluetooth Ring Scanner product, has an SE4400 scan engine.  Use 

2D Laser Imager 

Programming Bar Codes

 (page 5-1) to program the ring imager scan engine parameters.

Preparation

Assemble the Bluetooth Ring Scanner components.

Connect a ring decoder to the Bluetooth Ring Scanner module before inserting a battery into the module.  The Bluetooth Ring 
Scanner module performs initialization with the Ring Scanner on bootup.  A fully charged battery must be secured in the module 
battery well.

A ring scanner or ring imager can be tethered to the Bluetooth Ring Scanner module.  Either ring device can be used to read the 
Bluetooth Ring Scanner module programming bar codes in this section.

When parameters are changed, and saved to memory, the Bluetooth Ring Scanner module LED blinks.  Bar codes cannot be 
scanned until the LED color returns to normal mode.

The scan engine manufacturer may offer more bar codes and options than are contained in this guide.  Note that the bar codes 
in this guide are only those supported by Honeywell and the imagers or scanners linked to mobile devices that Honeywell 
manufactures or supports.  Contact 

Customer Support

 (page 10-1) if you need help when using the bar codes in this guide.

Module Programming Bar Codes

To change a parameter value scan the appropriate bar code in this section.  The new value replaces the default value in 
memory.  An asterisk (*) next to an option in this section indicates the default setting.

Note: Imager White LED programming bar codes have been replaced by the bar codes in 

Decoding Illumination

 (page 5-8) and 

LED Illumination

 (page 5-10).

Bluetooth Ring Scanner Module Factory Default Settings

Pairing Status

 (page 3-3)

Slave Mode Enabled

Suspend Timeout

 (page 3-4)

5 minutes

Beep on Reconnect

 (page 3-5)

Enabled

Reconnect Timeout

 (page 3-7)

30 seconds

Reconnect Timeout

 (page 3-7)

1 minute

Role Switching

 (page 3-8)

Enabled

Authentication

 (page 3-9)

Disabled

Encryption

 (page 3-9)

Disabled

PIN Code

 (page 3-12)

16 zeros

Friendly Name

 (page 3-13)

“LXE Scanner” + Module MAC address

Ring Imager Focus Mode

 (page 3-11)

Smart Focus

Beep Volume

 (page 3-10)

High

Summary of Contents for 8650

Page 1: ...8650 Bluetooth Ring Scanner User s Guide ...

Page 2: ...ithout the prior written consent of HII 2008 2015 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Trademarks RFTerm is a trademark or registered trademark of EMS Technologies Inc in the United States and or other countries The Bluetooth word mark and logos are owned by the Bluetooth SIG Inc Symbol is a registered trademark of Symbol Technologies MOTOROLA MOTO MOTO...

Page 3: ... 3 Bluetooth Ring Scanner Before Assembly 2 3 Bluetooth Module 2 3 Ring Imager Ring Scanner 2 4 Assembly 2 5 Determine Left or Right Orientation 2 5 Insert Module in Sleeve 2 5 Connecting the Ring Device Cable 2 6 Module Battery Help 2 7 Adjusting the Ring Device Strap 2 7 Status LEDs and Beep Indicators 2 7 Bluetooth Module Status LED and Beep Indicators 2 8 Bluetooth Ring Device LED 2 9 Rebootin...

Page 4: ...e Programming Bar Codes Introduction 3 1 Preparation 3 1 Module Programming Bar Codes 3 1 Restore Factory Defaults 3 2 Module Firmware Version 3 2 Pairing Status 3 3 Suspend Timeout 3 4 Beep on Reconnect 3 5 Reconnect Interval Timeout 3 6 Reconnect Timeout 3 7 Role Switching 3 8 Authentication 3 9 Encryption 3 9 Beep Volume 3 10 Ring Imager Focus Mode 3 11 Enter Friendly Name or PIN Code 3 12 PIN ...

Page 5: ...BEL 4 18 Baud Rate 4 18 Decode Data Packet Format 4 19 Host Character Time out 4 19 Intercharacter Delay 4 20 Software Handshaking 4 22 Stop Bit Select 4 23 Time out Between Decodes Same Symbol 4 23 Transmit No Read Decode Message 4 24 Trigger Mode 4 25 Scanner Parameters Bar Code Type Specific 4 26 Chinese 2 of 5 4 26 Codabar 4 27 CLSI Editing 4 27 NOTIS Editing 4 28 Set Lengths for Codabar 4 28 ...

Page 6: ...th Within Range 4 41 Any Length 4 41 Discrete 2 of 5 4 42 Set Lengths for Discrete 2 of 5 4 42 One Discrete Length Parameter L1 4 42 Two Discrete Lengths Parameter L2 4 43 Length Within Range 4 43 Any Length 4 43 Interleaved 2 of 5 4 44 I 2 of 5 Check Digit Verification 4 44 Convert I 2 of 5 to EAN 13 4 45 Set Lengths for I 2 of 5 4 45 One Discrete Length Parameter L1 4 45 Two Discrete Lengths Par...

Page 7: ...Coupon Extended Code 4 65 UPC EAN Security Level 4 66 GS1 DataBar RSS Codes 4 67 GS1 DataBar Omnidirectional RSS 14 4 67 GS1 DataBar Limited RSS Limited 4 67 GS1 DataBar Expanded RSS Expanded 4 68 Convert GS1 DataBar RSS to UPC EAN 4 68 Appendix 4 69 Laser On Time superseded 4 69 Scan Angle SE955 only superseded 4 69 Set Lengths for I 2 of 5 superseded 4 70 One Discrete Length Parameter L1 4 70 Tw...

Page 8: ...Read Message 5 25 UPC EAN 5 26 UPC A 5 26 UPC E 5 26 UPC E1 5 27 EAN 8 JAN 8 5 27 EAN 13 JAN 13 5 28 Bookland EAN 5 28 Bookland Format 5 29 Decode UPC EAN JAN Supplementals 2 and 5 digits 5 29 UPC EAN JAN Supplemental Redundancy 5 31 Transmit UPC A Check Digit 5 31 Transmit UPC E Check Digit 5 32 Transmit UPC E1 Check Digit 5 32 UPC A Preamble 5 33 UPC E Preamble 5 34 UPC E1 Preamble 5 35 Convert ...

Page 9: ...k Digits 5 49 Interleaved 2 of 5 ITF 5 50 Set Lengths for I 2 of 5 5 50 One Discrete Length Parameter L1 5 50 Two Discrete Lengths Parameter L2 5 51 Length Within Range 5 51 Any Length 5 51 I 2 of 5 Check Digit Verification 5 52 Transmit I 2 of 5 Check Digit 5 52 Convert I 2 of 5 to EAN 13 5 53 Discrete 2 of 5 DTF 5 53 Set Lengths for Discrete 2 of 5 5 54 Two Discrete Lengths Parameter L2 5 54 Len...

Page 10: ...DataBar RSS to UPC EAN 5 68 Composite 5 69 Composite CC C 5 69 Composite CC A B 5 69 Composite TLC 39 5 70 UPC Composite Mode 5 70 2D Symbologies 5 71 Aztec 5 71 Aztec Inverse 5 72 PDF417 5 72 MicroPDF417 5 73 Code 128 Emulation 5 73 Data Matrix 5 74 Data Matrix Inverse 5 74 Maxicode 5 75 MicroQR 5 75 QR Code 5 76 QR Inverse 5 76 Redundancy Level 5 77 Security Level 5 79 Intercharacter Gap Size 5 ...

Page 11: ... into the Charging Pocket 8 5 Removing the Battery from the Charging Pocket 8 5 Interpreting the Charging Pocket LEDs 8 5 Charge Timer 8 6 Charging Pocket 8 6 Inserting a Battery into the Charging Pocket 8 6 Removing the Battery from the Charging Pocket 8 7 Interpreting the Charging LED 8 7 Charge Timer 8 7 Battery Charger Help 8 8 Charger Cleaning Storage and Service 8 9 Cleaning 8 9 Storage 8 9 ...

Page 12: ...x Dimensions 9 2 ASCII Character Equivalents 9 2 Chapter 10 Customer Support Technical Assistance 10 1 Product Service and Repair 10 1 Limited Warranty 10 1 ...

Page 13: ...ant for the following models 8650 series 8651 8652 8653 8654 Bluetooth Ring Scanner Label Locations Caution RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE The battery should be disposed of by a qualified recycler or hazardous materials handler Do not incinerate the battery or dispose of the battery with general waste materials Left Side of Scanner head Right Side of Scanner Head Bot...

Page 14: ...T DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT 1 0 mW MAX OUTPUT 630 680nM Laser Warnings Do not look into the laser s lens Do not stare directly into the laser beam Do not remove the laser caution labels from the Bluetooth Ring Scanner ring bar code decoders Do not connect the laser bar code aperture to any other device The laser bar code aperture is certified for use with the Blueooth Ring Scann...

Page 15: ...ce in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications See dimension of field below Depth of Field 20 50 8 cm Width of Field 15 38 1 cm 10 31 6 cm 5 12 7 cm 0 0 cm 20 50 8 cm 15 38 1 cm 10 31 6 cm 5 12 7 cm 0 0 cm 5 12 7 cm 10 25 4 ...

Page 16: ...w operation instruction as documented in this manual EU Note This device is a 2 4 GHz wideband transmission system transceiver intended for use in all EU member states and EFTA countries except in France and Italy where restrictive use applies In Italy the end user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outd...

Page 17: ... 多溴联苯 PBB 多溴二苯醚 PBDE 扫描模块 Scanner Module x o o o o o 印刷电路部件 PCA x o o o o o 外壳 Housing x o o o o o 连接线 Cable x o o o o o o 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ T11363 2006 标准规定的限量要求以下 Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in China s SJ T11363 2006 x 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量要求 In...

Page 18: ...1 6 ...

Page 19: ...th another Bluetooth device the Bluetooth Ring Scanner Module can send serial data to the paired Bluetooth device The Bluetooth tethered ring scanner and tethered ring imager connectors are not interchangeable with other Honeywell mobile devices that also use tethered ring scanners or ring imagers i e Dolphin 70e Black in wearable sled HX2 or HX3 For information about other scanners such as tether...

Page 20: ... with the Bluetooth Module Hardware Setup 1 Determine which hand or wrist will contain the assembly 1 Insert the Bluetooth Ring Scanner Module into the leather sleeve 1 Thread ring cable connector through elastic loop on the appropriate side 1 Connect the ring cable connector to the Bluetooth Ring Scanner Module 1 Secure the module strap to the hand or wrist 1 Connect the ring cable connector to t...

Page 21: ...does not have a power or on off switch When the battery is installed the unit and its accessories are On Remove the battery to power down or turn off the unit 1 Module 2 Battery 3 Ring Scanner 4 Hand Strap Assembly 1 Battery Compartment Latch 2 Speaker 3 LED 4 Input Output Port Ring device cable connector ...

Page 22: ...er for processing The Bluetooth Ring Scanner module emits good read or bad read sounds based on the ring scan results See Status LEDs and Beep Indicators page 2 7 for an explana tion of the LED and beep patterns emitted These ring decoding devices do not have the ability to emit a good read or bad read sound Do not touch push against or brace your finger on the scan aperture at any time When new t...

Page 23: ... strap sizes to accommodate different sizes of wrists and hands Choose the best size for a secure fit Insert the module in the module sleeve on the hand strap before securing the hand strap to the hand if desired The mod ule is inserted in the sleeve with the LED facing upwards and visible through the circular cutout on the top of the module sleeve Press the loops on the top of the wrist strap aga...

Page 24: ...ice cable from the Bluetooth Ring Scanner module Inserting the Battery The battery is spring loaded and will slide out when the battery cover latch is opened As soon as the battery contacts lose connection with the battery terminals in the battery bay the Bluetooth module turns Off When a battery is in the module the battery slides out of the battery bay far enough to be grasped and removed Do not...

Page 25: ... high tone beep and the LED flashes Adjusting the Ring Device Strap The ring device finger loop is located under the ring device The ring device has a built in quick disconnect designed for safety hazards The quick disconnect is not intended for daily removal of the ring device 1 Pull gently on the end of the finger loop strap to separate the hook and loop fabric 1 Slide your finger into the opene...

Page 26: ...d paired device beeps on reconnect Bluetooth Module Status LED and Beep Indicators The Bluetooth Module blue LED and buzzer indicate status as follows Blue LED System Condition Indication Fast blink 0 25 sec duration every 1 0 sec Radio Failure Short high tone beep Short high tone beep Short low tone beep Short low tone beep Fast blink 0 25 sec duration every 1 0 sec Pairing Failed Short low tone ...

Page 27: ...quence Green User Good Scan Short high beep Green Configuration Good Scan Configuration process successful Three Short high beeps Red Scan in progress None Red Configuration Bad Scan Configuration process failed Three Short low beeps Slow blink Amber once every 25 sec Low Battery in the Bluetooth Module Four Short high beeps Off Suspend or Off not tethered or no battery power available in Bluetoot...

Page 28: ...al tools are needed The 3 7V 750mAhH Li Ion battery in the Bluetooth module is designed to power the Bluetooth module for 8 hours and remain in standby for approximately 24 hours The Bluetooth ring scanner module does not have a power or on off switch When the battery is installed the unit and its accessories are On Remove the battery to power down or turn off the unit Batteries are recharged in t...

Page 29: ...er module s Bluetooth LED flashes every 4 seconds This is the recommended method for pairing Note An unpaired Bluetooth Ring Scanner will re pair with the last device to which it was paired when it scans a regular non pairing bar code If the last paired device is not available then the Bluetooth Ring Scanner will remain unpaired In this case scanning a regular bar code is equivalent to scanning th...

Page 30: ...in the Bluetooth Devices panel can be cleared deleted in this manner if necessary The deleted Bluetooth Ring Scanner module is excluded from the list the next time the Bluetooth Devices panel is opened If you cannot disconnect delete the Bluetooth Ring Scanner module from the generic device at the end of the work day Contact your System Administrator for assistance Removing Replacing the Trigger M...

Page 31: ...ould slide easily Cleaning the Beam Aperture Note These instructions are for components made of glass If there is a removable protective film sheet on the beam aperture remove the film sheet before cleaning and before first use Keep fingers and rough sharp or abrasive objects away from the beam aperture If the aperture becomes soiled or smudged clean only with a standard household cleaner such as ...

Page 32: ...ropped up at an angle Scan a Linear Bar Code Holding the beam aperture approximately 3 12 inches away from the bar code aim the scan aperture toward the selected bar code Refer to the bar code reader engine type in Decode Zones later in this guide for recommended decode ranges Press the Scan button Align the scan beam so that the bar code is centered within the beam The beam must cross the entire ...

Page 33: ...mum read distance possible particularly with reflective labels use Code 39 The use of Code 128 or other more complex symbologies will almost always result in a reduction in maximum read distance Scanner maximum distances from Decode Zones when symbologies other than Code 39 are used are not supported Lens Damage A scratched scan beam aperture can impact read rates and distances Beam apertures shou...

Page 34: ...ammable Bar Codes Beep After Good Decode Audible scan progress indicators are generated by the scanner driver on mobile devices not the bar code decoder engine Use the Windows wedge panel options to set up the mobile device audible indicators Beeper Frequency Adjustment Audible scan progress indicators are generated by the scanner driver on mobile devices not the bar code decoder engine Use the Wi...

Page 35: ...ult settings remove the battery Replace the battery while pressing the ring scanner trigger for 30 or more seconds and the factory default configuration is restored Important After resetting the module to factory default settings the next step is to open the bar code wedge panel on the host mobile device collecting the scanned data Click the OK button to close the panel This action will synchroniz...

Page 36: ...2 18 ...

Page 37: ...g device can be used to read the Bluetooth Ring Scanner module programming bar codes in this section When parameters are changed and saved to memory the Bluetooth Ring Scanner module LED blinks Bar codes cannot be scanned until the LED color returns to normal mode The scan engine manufacturer may offer more bar codes and options than are contained in this guide Note that the bar codes in this guid...

Page 38: ...ideo display Bluetooth Ring Scanner must be fully assembled battery ring decoder 2 If necessary open a text editor on the host device make sure the cursor is in the open file then scan this bar code Scan this bar code with either the ring scanner or the ring imager to view the firmware version of the Bluetooth Ring Scan ner module on the host device display Restore Factory Defaults Module Firmware...

Page 39: ...itching page 3 8 Note The LnkB bar codes on some Bluetooth capable mobile devices are quite small If you are unsuccessful using the ring imager when scanning a LnkB bar code change the ring imager s default Smart Focus Mode to Near Focus by scanning the Enable Near Focus bar code Ensure focus mode is changed back to the default value of Smart Focus after the LnkB bar code read is successful Enable...

Page 40: ...quired to wake the module from Suspend Note After the trigger press to wake the module from Suspend another trigger press is needed to scan a bar code Disable Suspend Timeout Set Suspend Timeout to 15 seconds Set Suspend Timeout to 30 seconds Set Suspend Timeout to 1 minute Set Suspend Timeout to 5 minutes Set Suspend Timeout 15 minutes ...

Page 41: ...disabled and reconnect is unsuccessful over the reconnect interval the module emits a pat tern of a short high beep and a short low beep and the blue LED blinks fast every 1 second Scan the Disable Beep on Reconnect to disable audible notification for connect and disconnect Set Suspend Timeout to 30 minutes Set Suspend Timeout to 45 minutes Set Suspend Timeout to 60 minutes Enable Beep on Reconnec...

Page 42: ...unt of time between attempts to reconnect with a previously connected Bluetooth enabled device Reconnect Interval Timeout 15 seconds Reconnect Interval Timeout 30 seconds Reconnect Interval Timeout 45 seconds Reconnect Interval Timeout 1 minutes Reconnect Interval Timeout 5 minutes ...

Page 43: ...tion attempts before ceas ing attempts When the parameter is set to Off reconnect attempts will continue until the battery in the Bluetooth module is depleted Reconnect Interval Timeout 10 minutes Reconnect Interval Timeout 15 minutes Reconnect Interval Timeout 30 minutes Reconnect Timeout Off Reconnect Timeout 1 minute ...

Page 44: ...ly paired with an Bluetooth capable mobile device as a master the module will perform role switching with the mobile device and become a slave device Reconnect Timeout 5 minutes Reconnect Timeout 30 minutes Reconnect Timeout 60 minutes Enable Role Switching Disable Role Switching ...

Page 45: ...e Bluetooth Ring Scanner module When Authentication is enabled the connecting device is required to enter the PIN value set by the Bluetooth Ring Scanner module before suc cessful connection can occur Encryption Encryption is the process of encoding data for transmission between devices to ensure its integrity Enable Authentication Disable Authentication Enable Encryption Disable Encryption ...

Page 46: ...3 10 Beep Volume The Bluetooth Module speaker volume can be reset by scanning one of the following bar codes Volume Off Volume Low Volume Medium Volume High ...

Page 47: ...4400 Scan Engine Technical Specifications for typical working ranges for the Ring Imager decoder The focus mode persists over a power cycle remove and replace the module battery This parameter reverts to the default setting after a module Reset holding the imager trigger for 30 seconds after reinstall ing the module battery It reverts to the default setting after the Factory Defaults bar code is s...

Page 48: ...lpha and uppercase alpha bar codes 2 When finished entering all characters scan the Stop PIN Code setup bar code 3 Scan the Stop PIN Code setup bar code to end PIN Code data entry The PIN Code default is 16 zeros 0000000000000000 To reset the Pin Code back to the default scan the Set Pin Code bar code and the Pin Code Default bar code only Set PIN Code Pin Code Default Stop PIN Code setup ...

Page 49: ...rs lowercase alpha and uppercase alpha bar codes 2 When finished entering all characters scan the Stop Friendly Name setup bar code to end Friendly Name data entry 3 The Friendly Name default value is LXE Scanner MAC address in Hexadecimal The Friendly Name can be viewed using EZ Pairing on the paired mobile device Set Friendly Name Stop Friendly Name setup ...

Page 50: ...3 14 Numbers Cancel current programming function 0 1 2 3 4 ...

Page 51: ...3 15 5 6 7 8 9 ...

Page 52: ...3 16 Lowercase Letters Cancel current programming function a b c d e ...

Page 53: ...3 17 f g h i j k l ...

Page 54: ...3 18 m n o p q r s ...

Page 55: ...3 19 t u v w x y z ...

Page 56: ...3 20 Uppercase Letters Cancel current programming function A B C D E ...

Page 57: ...3 21 F G H I J K L ...

Page 58: ...3 22 M N O P Q R S ...

Page 59: ...3 23 T U V W X Y Z ...

Page 60: ...3 24 ...

Page 61: ...tained in this chapter Note that the bar codes in this chapter are only those supported by Honeywell and the mobile devices it manufactures or supports Contact Customer Support page 10 1 if you need help using the bar codes in this guide To change a parameter value Scan the appropriate bar code in this section The new value replaces the standard default value in memory The following bar code symbo...

Page 62: ...x Ring decoder engine prefix and suffix parameters should not be set changed or reset using the Prefix and Suffix bar codes shown in this section When the Bluetooth Ring Scanner module is reset to defaults the prefix and suffix settings revert to their default values and need to be scanned again Use the ScanWedge ScanWedge NGW Power Tool Dolphin 70e or Data Collection Scanner control panel all oth...

Page 63: ...A Preamble page 4 59 System Character UPC E Preamble page 4 60 System Character UPC E1 Preamble page 4 61 System Character Convert UPC E to UPC A page 4 57 Disable Convert UPC E1 to UPC A page 4 57 Disable Convert EAN 8 to EAN 13 Type page 4 58 Type is EAN 13 EAN 8 Zero Extend page 4 65 Disable UPC EAN Security Level page 4 66 0 UCC Coupon Extended Code page 4 65 Disable Linear UPC EAN Decode Not ...

Page 64: ...ert I 2 of 5 to EAN 13 page 4 45 Disable Discrete 2 of 5 Discrete 2 of 5 page 4 42 Disable Set Lengths for Discrete 2 of 5 page 4 42 12 Chinese 2 of 5 Chinese 2 of 5 page 4 26 Disable Codabar page 4 27 CLSI Editing page 4 27 Disable NOTIS Editing page 4 28 Disable Set Lengths for Codabar page 4 28 Length within Range 05 55 MSI Plessey MSI Plessey page 4 48 Disable Set Lengths for MSI Plessey page ...

Page 65: ...ial Response Time out page 4 19 2 sec Host Character Time out page 4 19 200 msec Macro PDF Macro PDF Transmit Decode Mode Not Supported Transmit Each Symbol in Codeword Format Not Supported Transmit Unknown Codewords Not Supported Escape Character Not Supported ECI Delete Character Set ECIs Not Supported ECI Decoder Not Supported Transmit Macro PDF User Selected Field Transmit File Name Not Suppor...

Page 66: ...ore Defaults to restore the factory default values Set Factory Defaults Restore the factory default values If custom defaults were set they are eliminated Write Custom Defaults Store the current scanner settings as custom defaults Once custom default settings are stored they can be recovered at any time by scanning the Restore Defaults bar code See Also Reset page 2 10 Restore Defaults Set Factory...

Page 67: ...odes that correspond to the desired aim duration Times less than 1 0 second must have a leading zero For example to set an aim duration of 0 5 seconds scan the bar code above then scan the 0 and 5 bar codes on Keypad Number Symbols page 4 72 If you make an error or wish to change your selection scan the Cancel bar code Bi Directional Redundancy Use this parameter to decide whether a bar code is su...

Page 68: ...anned again Use the ScanWedge ScanWedge NGW Power Tool Dolphin 70e or Data Collection Scanner control panel all others in the host computer to store prefix and suffix values Scan Data Transmission Format page 4 9 must be set before selecting Prefix Suffix values A prefix and or one or two suffixes may be appended to scan data for use in data editing These values are set by scanning four bar codes ...

Page 69: ...eric bar codes that correspond to the computer keycode using the Keypad Number Symbols page 4 72 If you wish to change your numeric selection scan Cancel on the Keypad Number Symbols page Scan Data Transmission Format Note Parameter Prefix and Suffix page 4 8 should be set after setting this parameter Use this option when you want to append a prefix and suffix to the decode data Set this parameter...

Page 70: ...4 10 Data Suffix 1 Suffix 2 Prefix Data Prefix Data Suffix 1 Prefix Data Suffix 2 Prefix Data Suffix 1 Suffix 2 ...

Page 71: ...bol Scan one of the following bar codes to select either no code ID character a Symbol Code ID character or an AIM Code ID character Transmit No Code ID Character Transmit Symbol Code ID Character A UPC A UPC E UPC E1 EAN 8 EAN 13 B Code 39 Code 32 C Codabar D Code 128 ISBT 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA H Code 11 J MSI Plessey K UCC EAN 128 L Bookland...

Page 72: ...d check character 4 Reader has performed Full ASCII character conversion 5 Reader has performed Full ASCII character conversion and checked one check character 7 Reader has performed Full ASCII character conversion and checked and stripped check character Example A Full ASCII bar code with check character W A I MI DW is transmitted as A7AimId where 7 3 4 Trioptic Code 39 0 No option specified at t...

Page 73: ...ansmit 0 Example A Code 93 bar code 012345678905 is transmitted as G0012345678905 MSI Plessey 0 Single check digit checked 1 Two check digits checked 2 Single check digit verified and stripped before transmission 3 Two check digits verified and stripped before transmission Example An MSI Plessey bar code 4123 with a single check digit checked is transmitted as M04123 Discrete 2 of 5 0 No options s...

Page 74: ... If a label has not been decoded before this time expires and the session is ter minated the system regards it as a failed scan attempt To begin setting Laser On Time scan this bar code Next scan two numeric bar codes that correspond to the desired on time using the Keypad Number Symbols page 4 72 Times less than 1 0 second must have a leading zero If you wish to change your number selection scan ...

Page 75: ... Note Linear Code Type Security does not apply to Code 128 Level 1 The following code types must be successfully read twice before being decoded Codabar All lengths MSI Plessey Length of 4 characters or less D 2 of 5 Length of 8 characters or less I 2 of 5 Length of 8 characters or less Level 2 All code types must be successfully read twice before being decoded Level 3 Code types other than the fo...

Page 76: ...rameters can be set using the bar codes in this section Note When this parameter is disabled scan the Set Default Parameter page 4 6 bar code to enable parameter scanning When disabled either scan the Enable Parameter Scanning bar code or the Set All Defaults bar code or set this parameter to 01h via a serial command to reset the parameter and bar codes in this section can then be scanned When ena...

Page 77: ... power mode after one second of waiting for a Scan button press Pressing the Scan button will begin the decode sequence Select a Power Mode by scanning either of the bar codes shown below Scan Angle SE955 only Choose one of the options below to set the scan angle to narrow or wide Once the parameter bar code is scanned the Scan Angle setting is persistently stored Select an option by scanning one ...

Page 78: ...e setting of the host device If not data may not reach the host device or may reach it in distorted form Baud rate should always be set to 9600 If the baud rate is set to any other value but 9600 a transmit error will occur Either scan the 9600 bps bar code or reset the mobile device to factory default or last saved good default values Set this parameter by scanning this bar code The SSI Options b...

Page 79: ...e scan this bar code Next scan two numeric bar codes that correspond to the desired value using the Keypad Number Symbols at the end of this chapter Single digit numbers must have a leading zero For example a value of 300 msec is selected by scan ning the 3 and the 0 numeric bar codes A value of 30 msec is selected by scanning the 0 and the 3 bar codes If you wish to change your selection scan Can...

Page 80: ...ar code below scan two numerical bar codes to set the delay To begin setting the delay value scan this bar code Next scan two numeric bar codes that correspond to the desired value using the Keypad Number Symbols page 4 72 at the end of this chapter Time durations of less than 1 msec require a leading zero For example a value of 25 msec is selected by scanning the 2 and the 5 numeric bar codes A v...

Page 81: ...d the host programmer when writing host scanner interface programs for different hosts Contact Customer Support page 10 1 for technical help Mark Parity The parity bit is always 1 Space Parity The parity bit is always 0 No Parity No parity is required ...

Page 82: ...odes to set software handshaking Disable ACK NAK Handshaking When this option is selected the decoder will neither generate nor expect ACK NAK handshaking packets Enable ACK NAK Handshaking When this option is selected after transmitting data the scanner expects either an ACK or NAK response from the host The scanner will also ACK or NAK messages from the host when this option is selected The scan...

Page 83: ...tomer Support page 10 1 for technical help Time out Between Decodes Same Symbol Default 1 0 second Use this parameter to prevent the beeper from continuously beeping when a symbol is left in the scanner s field of view To begin setting differing symbol timeout values scan this bar code Using the Keypad Number Symbols page 4 72 section at the end of this chapter scan two numeric bar codes that repr...

Page 84: ...nd decode processing the processing continues until a scan button release or The laser decode processing continues until the Laser On Timeout is reached A NR No Read is transmitted to the host Any prefix or suffixes which have been enabled are appended around this message When disabled and a symbol does not decode no message is sent to the host Select an option by scanning either of the bar codes ...

Page 85: ...sing The laser remains on and decode processing continues until a trigger release a valid decode or the Laser On Time out is reached Pulse A trigger pull or Scan button press activates the laser and decode processing The laser remains on and decode processing continues until a valid decode or the Laser On Time out is reached Continuous The laser is always on and decoding See Also Time out Between ...

Page 86: ...ype Specific Chinese 2 of 5 When enabled Chinese 2 of 5 symbols will be scanned decoded and transmitted Set this parameter by scanning either of the bar codes shown below Blinking Host Cancel Enable Chinese 2 of 5 Disable Chinese 2 of 5 ...

Page 87: ...n enabled the start and stop characters are stripped from the bar code and a space is inserted after the 1st 5th and 10th characters of a 14 character Codabar symbol Set this parameter by scanning either of the bar codes shown below Note Symbol length does not include start and stop characters Enable Codabar Disable Codabar Enable CLSI Editing Disable CLSI Editing ...

Page 88: ...haracters See the table titled ASCII Character Equivalents page 9 2 One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only Codabar symbols containing 14 characters scan the Codabar One Discrete Length bar code and then 1 and 4 bar codes using the Keypad Number Symbols page 4 72 To begin setting one discrete length s...

Page 89: ... selection scan Cancel on the Keypad Number Symbols page Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only Codabar symbols containing between 4 and 12 characters scan the Codabar Length Within Range bar code and then 0 4 1 and 2 bar codes To begin setting lengths within a range scan this bar code Next scan numeri...

Page 90: ...scan only Code 11 symbols containing 14 characters scan the Code 11 One Discrete Length bar code and then 1 and 4 bar codes using the Keypad Number Symbols page 4 72 To begin setting one discrete length scan this bar code Next scan two numeric bar codes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the ...

Page 91: ...e 11 symbols containing between 4 and 12 characters scan the Code 11 Length Within Range bar code and then 0 4 1 and 2 bar codes To begin setting lengths within a range scan this bar code Next scan numeric bar codes that correspond to the desired value using the Keypad Number Symbols page 4 72 Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on ...

Page 92: ...thm Note Enable Code 11 Check Digit Verification when Transmit Code 11 Check Digits is enabled Set this parameter by scanning one of the bar codes shown below Transmit Code 11 Check Digits Note Code 11 Check Digit Verification must be enabled for this parameter to function Disable this feature One Check Digit Two Check Digits Transmit Enable Do Not Transmit Disable ...

Page 93: ...ing strips off the leading FNC 1 character and replaces other FNC 1 characters with the ASCII 29 GS control character When AIM symbology identifiers are transmitted the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines For example c1 indicates a GS1 128 symbol with a leading FNC1 character Standard Code 128 bar codes which do not have a leading FN...

Page 94: ...Examples FNC1 ABCDFNC1 E are read as ABCD29 E AFNC1BCDFNC1E are read as ABCD29E FNC1FNC1 ABCDFNC1 E are read as ABCD29 E ABCDFNC1E cannot be read ABCDE cannot be read Enable Disable Read only symbols without leading FNC1 Examples FNC1 ABCDFNC1 E cannot be read AFNC1 BCDFNC1 E cannot be read FNC1FNC1 ABCDFNC1 E cannot be read ABCDFNC1 E is read as ABCD29 E ABCDE is read as ABCDE Enable Enable Read ...

Page 95: ...en enabled this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms Only those Code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled Set this parameter by scanning either of the bar codes shown below Enable Code 39 Disable Code 39 Enable Code 39 Check Digit Verification Disable Code 39 Check Digit Verificatio...

Page 96: ...hown below Convert Code 39 to Code 32 Note Code 39 must be enabled in order for this parameter to function Note When parameter Code 32 Prefix is to be enabled this Convert Code 39 to Code 32 Italian Pharma Code parameter must also be enabled Set this parameter by scanning either of the bar codes shown below Enable Code 32 Prefix Disable Code 32 Prefix Enable Convert Code 39 to Code 32 Disable Conv...

Page 97: ... 39 may be set for any length one or two discrete lengths or lengths within a specific range The length of a code refers to the number of characters including check digits the code contains If Code 39 Full ASCII is enabled Length Within a Range or Any Length are the preferred options See the table titled ASCII Character Equivalents page 9 2 Code 39 One Discrete Length Parameter L1 This option deco...

Page 98: ...ection scan Cancel on the Keypad Number Symbols page Code 39 Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only Code 39 symbols containing between 4 and 12 characters scan the Code 39 Length Within Range bar code and then 0 4 1 and 2 bar codes using the Keypad Number Symbols page 4 72 To begin setting lengths with...

Page 99: ...ng either of the bar codes shown below Trioptic Code 39 Trioptic Code 39 symbols always contain six characters When Trioptic Code 39 is enabled set the Code 39 Full ASCII parameter to disabled Both parameters should not be enabled simultaneously Set this parameter by scanning either of the bar codes shown below Enable Transmit Code 39 Check Digit Disable Transmit Enable Trioptic Code 39 Disable Tr...

Page 100: ... Character Equivalents page 9 2 One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only Code 93 symbols containing 14 characters scan the Code 93 One Discrete Length bar code and then 1 and 4 bar codes using the bar codes on the Keypad Number Symbols page 4 72 To begin setting one discrete length scan this bar code N...

Page 101: ...n Cancel on the Keypad Number Symbols page Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only Code 93 symbols containing between 4 and 12 characters scan the Code 93 Length Within Range bar code and then 0 4 1 and 2 bar codes using the Keypad Number Symbols page 4 72 at the end of this chapter To begin setting len...

Page 102: ...le titled ASCII Character Equivalents page 9 2 One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only D 2 of 5 symbols containing 14 characters scan the D 2 of 5 One Discrete Length bar code and then 1 and 4 bar codes using the bar codes on the Keypad Number Symbols page 4 72 page To begin setting one discrete lengt...

Page 103: ...ge Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only D 2 of 5 symbols containing between 4 and 12 characters scan the D 2 of 5 Length Within Range bar code and then 0 4 1 and 2 bar codes using the Keypad Number Symbols page 4 72 To begin setting lengths within a range scan this bar code Next scan numeric bar code...

Page 104: ...erification When enabled this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algo rithm either USS Uniform Symbology Specification or OPCC Optical Product Code Council Set this parameter by scanning one of the bar codes shown below Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Disable I 2 of 5 Check Digit Verification USS Check Digit OPCC Check D...

Page 105: ...ers including check digits the code contains When settings lengths single digit numbers must always be preceded by a leading zero See the table titled ASCII Character Equivalents page 9 2 One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to decode I 2 of 5 symbols containing only 14 characters scan the I 2 of 5 One Discrete...

Page 106: ...th Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only I 2 of 5 symbols containing between 4 and 12 characters scan the I 2 of 5 Length Within Range bar code and then 0 4 1 and 2 bar codes using the Keypad Number Symbols page 4 72 at the end of this section To begin setting lengths within a range scan this I 2 of 5 Length...

Page 107: ... is transmitted with the data Parameter setting for I 2 of 5 Check Digit Verification has no effect on this parameter value Set this parameter by scanning either of the bar codes shown below Enable Transmit I 2 of 5 Check Digit Disable Transmit I 2 of 5 Check Digit ...

Page 108: ... shown below MSI Plessey Check Digit Algorithm When the Two MSI Plessey Check Digits option is selected an additional verification is required to ensure integrity Either of the two following algorithms may be selected Set this parameter by scanning either of the algorithm bar codes shown below Enable MSI Disable MSI Mod 10 Mod 11 Mod 10 Mod 10 ...

Page 109: ...a specific range The length of a code refers to the number of characters including check digits the code contains See the table titled ASCII Character Equivalents page 9 2 One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only MSI Plessey symbols containing 14 characters scan the MSI Plessey One Discrete Length bar ...

Page 110: ...Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only MSI Plessey symbols containing between 4 and 12 characters scan the MSI Plessey Length Within Range bar code and then 0 4 1 and 2 bar codes using the Keypad Number Symbols page 4 72 To begin setting lengths within a range scan this bar code Next scan numeric bar c...

Page 111: ...ssey Check Digit When enabled the check digit is transmitted with the data Set this parameter by scanning either of the bar codes shown below Enable Transmit MSI Plessey Check Digit Disable Transmit MSI Plessey Check Digit ...

Page 112: ...4 52 UPC EAN UPC A Select an option by scanning either of the bar codes shown below UPC E Select an option by scanning either of the bar codes shown below Enable UPC A Disable UPC A Enable Disable ...

Page 113: ... 53 UPC E1 Select an option by scanning either of the bar codes shown below EAN 8 Select an option by scanning either of the bar codes shown below Enable UPC E1 Disable UPC E1 Enable EAN 8 Disable EAN 8 ...

Page 114: ... Select an option by scanning either of the bar codes shown below Bookland EAN Select an option by scanning either of the bar codes shown below Enable EAN 13 Disable EAN 13 Enable Bookland EAN Disable Bookland EAN ...

Page 115: ...EAN 13 in 13 digit format to meet the 2007 ISBN 13 protocol For Bookland EAN to function properly first enable Bookland EAN using Enable Disable Bookland EAN then select either Decode UPC EAN Supplementals Autodiscriminate UPC EAN Supplementals or Enable 978 979 Supplemen tal Mode in Decode UPC EAN Supplementals Check Digits Transmit UPC A Check Digit This parameter determines whether the symbol w...

Page 116: ...her of the bar codes shown below Transmit UPC E1 Check Digit This parameter determines whether the symbol will be transmitted with or without the UPC E1 check digit Select an option by scanning either of the bar codes shown below Enable Transmit UPC E Check Digit Disable Transmit UPC E Check Digit Enable Transmit UPC E1 Check Digit Disable Transmit UPC E1 Check Digit ...

Page 117: ...ing either of the bar codes shown below Convert UPC E1 to UPC A When this parameter is enabled UPC E1 zero suppressed decoded data is converted to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit etc When disabled UPC E1 zero suppressed decoded data is transmitted without conversion Select an option...

Page 118: ...s parameter setting labels the extended symbol as either an EAN 13 bar code or an EAN 8 bar code When EAN 8 Zero Extend is disabled this parameter s conversion setting is ignored Select an option by scanning either of the bar codes shown below Type is EAN 13 Type is EAN 8 ...

Page 119: ...cters are considered part of the symbol Data is sent to the host in the following format Select an option by scanning one of the bar codes shown below No Preamble data System Character schar data System Character and Country Code country code schar data No UPC A Preamble System Character System Character and Country Code 0 for USA ...

Page 120: ... are considered part of the symbol Data is sent to the host in the following format Select an option by scanning one of the bar codes shown below No Preamble data System Character schar data System Character and Country Code country code schar data No UPC E Preamble System Character System Character and Country Code 0 for USA ...

Page 121: ... are considered part of the symbol Data is sent to the host in the following format Select an option by scanning one of the bar codes shown below No Preamble data System Character schar data System Character and Country Code country code schar data No UPC E1 Preamble System Character System Character and Country Code 0 for USA ...

Page 122: ... supplemental symbol is scanned the UPC EAN is decoded and the supplemental characters ignored Autodiscriminate UPC EAN Supplementals When this option is selected you must assign a value to the Decode UPC EAN Supplemental Redundancy parameter A value of 5 or more is recommended Enable 378 379 Supplemental Mode The scanner will identify supplementals for EAN 13 bar codes that start with a 378 or 37...

Page 123: ...ntal Mode Enable 491 Supplemental Mode Enable Smart Supplemental Mode Applies to EAN 13 bar codes starting with any prefix listed previously Supplemental User Programmable Type 1 Supplemental User Programmable Type 1 and 2 Smart Supplemental Plus User Programmable 1 ...

Page 124: ...72 Decode UPC EAN Supplemental Redundancy Default 7 Times With Autodiscriminate UPC EAN Supplementals selected this option adjusts the number of times a symbol without supplementals will be decoded before transmission The range is from 2 to 20 times Five or above is recommended when decoding a mix of UPC EAN symbols with and without supplementals and the autodiscriminate option is selected To begi...

Page 125: ...arameter Convert EAN 8 to EAN 13 Type setting is ignored Select an option by scanning either of the bar codes shown below UCC Coupon Extended Code Note UCC Coupon Extended Code replaces UPC EAN Coupon Code The UCC Coupon Extended Code is an additional bar code adjacent to a UCC Coupon Code To enable or disable UCC Coupon Extended Code scan the appropriate bar code below Enable EAN 8 Zero Extend Di...

Page 126: ...ile providing sufficient security in decoding in spec UPC EAN bar codes Level 1 Misdecode 1 2 7 8 As bar code quality levels diminish certain characters become prone to misdecodes before others i e 1 2 7 8 Select this level upon misdecodes of poorly printed labels that are limited to 1 2 7 and 8 Level 2 Misdecodes not 1 2 7 8 Select this security level upon experiencing misdecodes of poorly printe...

Page 127: ...rs Disable GS1 DataBar Omnidirectional RSS 14 GS1 DataBar Limited RSS Limited Cancel Enable GS1 DataBar Omnidirectional RSS 14 Disable GS1 DataBar Omnidirectional RSS 14 Enable GS1 DataBar Limited RSS Limited Disable GS1 DataBar Limited RSS Limited ...

Page 128: ...ve the leading 010 stripped and the bar code reported as EAN 13 Bar codes beginning with two or more zeros but not six zeros have the leading 0100 stripped and the bar code reported as UPC A The UPC A Preamble parameter to transmit the system character and country code applies to converted bar codes Note that neither the system character nor the check digit can be stripped Enable GS1 DataBar Expan...

Page 129: ...nd the session is termi nated the system regards it as a failed scan attempt To begin setting Laser On Time scan this bar code Next scan two numeric bar codes that correspond to the desired on time using the Keypad Number Symbols page 4 72 at the end of this section Times less than 1 0 second must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symb...

Page 130: ...mbols page 4 72 To begin setting one discrete length scan this I 2 of 5 One Discrete Length bar code Next scan two numeric bar codes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected...

Page 131: ...d of this section To begin setting lengths within a range scan this I 2 of 5 Length Within Range bar code Next scan numeric bar codes that correspond to the desired value Single digit numbers must have a leading zero If you wish to change your number selection scan Cancel on the Keypad Number Symbols page Any Length This option decodes I 2 of 5 bar codes containing any number of characters Note Im...

Page 132: ...low represent a numeric keypad with decimal values 0 through 9 Each label can be scanned individually to enter a numeric value Use these numeric value symbols to enter numeric input in the course of performing a scan engine system configuration 0 1 2 3 4 5 ...

Page 133: ...4 73 6 7 8 9 Cancel ...

Page 134: ...4 74 ...

Page 135: ...ostal Code symbologies is Enabled For best performance when reading a specific postal symbology all other postal symbologies should be disabled Note Prefix Suffix Ring decoder engine prefix and suffix parameters should not be set changed or reset using the Prefix and Suffix bar codes shown in this section When the Bluetooth Ring Scanner Module is reset to defaults the prefix and suffix settings re...

Page 136: ...5 15 Trigger Mode PL4407 Level Trigger Modes page 5 15 Trigger Mode MS4407 Presentation Mode Report Version page 5 16 Current Software Version Transmit Code ID Character page 5 16 None Prefix Suffix Values page 5 22 Prefix Null Suffix 1 LF Suffix 2 CR Scan Data Transmission Format page 5 23 Data As Is Transmit No Read Message page 5 25 Disable Simple Serial Interface SSI Options Not Supported Even...

Page 137: ...t Verification page 5 43 Disable Transmit Code 39 Check Digit page 5 44 Disable Code 39 Full ASCII Conversion page 5 44 Disable Code 93 Code 93 page 5 45 Disable Set Lengths for Code 93 page 5 45 4 to 55 Code 11 Code 11 page 5 47 Disable Set Lengths for Code 11 page 5 47 4 to 55 Code 11 Check Digit Verification page 5 49 Disable Transmit Code 11 Check Digits page 5 49 Disable Interleaved 2 of 5 IT...

Page 138: ...e GS1 DataBar Expanded RSS Expanded page 5 68 Enable Convert GS1 DataBar RSS to UPC EAN page 5 68 Disable Composite Composite CC C page 5 69 Disable Composite CC A B page 5 69 Disable Composite TLC 39 page 5 70 Disable UPC Composite Mode page 5 70 UPC Always Linked Composite Beep Mode Not Supported UCC EAN Code 128 Emulation Mode page 5 70 Disable 2D Symbologies Aztec page 5 71 Enable Aztec Invers...

Page 139: ...ters are changed the new value replaces the standard default value in memory See Pre Configured Defaults page 5 1 for an alphabetical listing of all default values See Also Reset page 2 10 Intercharacter Gap Size page 5 80 Normal Macro PDF Not Supported Macro PDF Transmit Decode Mode Symbols Not Supported Transmit Macro PDF Control Header Not Supported Escape Characters Not Supported Flush Macro P...

Page 140: ...wedge panel resident on the host mobile device Bar code manipulation parameters assigned using the Bar Code Wedge panels are applied to the data resulting from successful bar code scans Decode Session Timeout Default 9 9 Seconds This parameter sets the maximum time decode processing continues during a scan attempt It is programmable in 0 1 sec ond increments from 0 5 to 9 9 seconds If a label has ...

Page 141: ...oexposure Select Enable Autoexposure to allow the imager to control gain settings and exposure integration time to best capture an image for the selected operation mode Select Disable Autoexposure to manually adjust the gain and exposure time not supported in this version This option is only recommended for advanced users with difficult image capture situations Enable Decode Aiming Pattern Disable...

Page 142: ...ed above the scan aperture Note Enable this parameter for LED illumination upon every decode The effectiveness of the illumination decreases as the distance to the target increases Disable this parameter to prevent LED illumination See LED Illumination page 5 10 Select a setting by scanning one of the bar codes shown below Enable Illumination Disable Illumination ...

Page 143: ...ptimized to read at its far position With Near Focus the imager is optimized to read at its near position Smart Focus toggles the focus position after every frame There may be audible signals from the ring imager as Smart Focus toggles after every frame Scan the appropriate bar code below Far Focus Near Focus Smart Focus ...

Page 144: ...l bright LEDs situated above the scan aperture Internal LED illumination turns the LEDs on during scan mode The effectiveness of the illumination decreases as the distance to the target increases External illumination setting turns the LEDs off during scan mode Internal and External Illumination turns the LEDs on during scan mode See Decoding Illumination page 5 8 Select an illumination setting by...

Page 145: ... adjusts to the lighting conditions Hold the imager steady until the image is captured denoted by a single beep If a trigger event is not activated within the Snapshot Mode Timeout period the decoder returns to Decode Mode Use Snapshot Mode Timeout not supported in this version to adjust this timeout period The default timeout period is 30 seconds To disable the laser aiming pattern during Snapsho...

Page 146: ...ad read then scan again This parameter determines how long the ring decoder will attempt to decode a bar code before determining if it is a good read or a bad read Presentation Mode means the ring decoder is always On and will scan bar codes that enter its field of view Presentation Mode applies to Decode Mode only See also Trigger Modes page 5 15 Default 2 Seconds To set the duration of the attem...

Page 147: ...ns active after decoding The decoder wakes upon a Scan button press or when the host attempts to communicate with the decoder This parameter only applies when Power Mode is set to Low Power 1 Second Delay 5 Second Delay 1 Minute Delay 5 Minute Delay 15 Minute Delay 60 Minute Delay ...

Page 148: ... is programmable in 0 1 second increments from 0 0 to 9 9 seconds To select the timeout between decodes for the same symbol scan the following bar code then scan two numeric bar codes from the Imager Keypad Number Symbols page 5 81 at the end of this chapter that correspond to the desired interval in 0 1 second increments Times less than 1 0 second must have a leading zero If you wish to change yo...

Page 149: ...button press activates the laser and decode processing The laser remains on and decode processing continues until a Scan button release a valid decode or the decode session time out is reached Presentation Trigger Mode When the ring scanner detects an object in its field of view it scans and attempts to decode The range of object detection does not vary under normal lighting conditions This applie...

Page 150: ...th the ring imager Transmit Code ID Character Default None A code ID character identifies the code type of a scanned bar code This may be useful when the imager is decoding more than one code type In addition to any single character prefix already selected the code ID character is inserted between the prefix and the decoded symbol Scan one of the following bar codes to select either no code ID cha...

Page 151: ...f 5 or Discrete 2 of 5 IATA H Code 11 J MSI Plessey K UCC EAN 128 L Bookland EAN M Trioptic Code 39 N Coupon Code R RSS 14 RSS Limited RSS Expanded T UCC Composite TLC 39 X PDF417 MacroPDF417 MicroPDF417 P00 Data Matrix P01 QR Matrix P02 Maxicode P03 US Postnet P04 US Planet P05 Japan Postal P06 UK Postal P08 Dutch Postal P09 Australian Postal P09 UK Postal ...

Page 152: ...de 39 Trioptic Bookland EAN US Postnet US Planet UK Postal Japan Postal Australian Postal Dutch Postal Code Type Option Value Option Code39 0 No Check character or Full ASCII processing 1 Reader has checked one check character 3 Reader has checked and stripped check character 4 Reader has performed Full ASCII character conversion 5 Reader has performed Full ASCII character conversion and checked o...

Page 153: ...78905 is transmitted as G0012345678905 MSI Plessey 0 Single check digit checked 1 Two check digits checked 2 Single check digit verified and stripped before transmission 3 Two check digits verified and stripped before transmission Example An MSI Plessey bar code 4123 with a single check digit checked is transmitted as M04123 D 2 of 5 0 No options specified at this time Always transmit 0 Example A ...

Page 154: ...ve been invoked or whether data byte 92DEC has been doubled in transmission 1 Reader set to follow the ECI protocol Extended Channel Interpretation All data characters 92DEC are doubled 2 Reader set for Basic Channel operation no escape character transmission protocol Data characters 92DEC are not doubled Note When decoders are set to this mode unbuffered Macro symbols and symbols requiring the de...

Page 155: ...ing E00012345678905 E110 QR Code 0 Model 1 symbol 1 Model 2 symbol ECI protocol not implemented 2 Model 2 symbol ECI protocol implemented 3 Model 2 symbol ECI protocol not implemented FNC1 implied in first position 4 Model 2 symbol ECI protocol implemented FNC1 implied in first position 5 Model 2 symbol ECI protocol not implemented FNC1 implied in second position 6 Model 2 symbol ECI protocol impl...

Page 156: ...er that correspond to key codes for various mobile devices Note See the table titled ASCII Character Equivalents page 9 2 for keycodes Note Prefix To begin setting Prefix values for SSI hosts first set the Scan Data Transmission Format then scan this Scan Prefix bar code Next scan four numeric bar codes that correspond to the computer key code using Imager Keypad Number Symbols page 5 81 at the en...

Page 157: ...ttings revert to their default values and need to be scanned again Use the ScanWedge ScanWedge NGW Power Tool Dolphin 70e or Data Collection Scanner control panel all others in the host computer to store prefix and suffix values Note Use this option when you want to append a prefix and suffix to the SSI host decode data If you wish to change your selection scan the Cancel bar code and scan again S...

Page 158: ...5 24 Prefix Data Suffix 1 Prefix Data Suffix 2 Prefix Data Suffix 1 Suffix 2 Cancel ...

Page 159: ... to select whether or not to transmit a No Read message When enabled the characters NR are transmitted when a bar code is not decoded When disabled if a symbol does not decode nothing is sent to the host Enable Transmit No Read Disable Transmit No Read ...

Page 160: ...6 UPC EAN UPC A Select an option by scanning either of the bar codes shown below UPC E Select an option by scanning either of the bar codes shown below Enable UPC A Disable UPC A Enable UPC E Disable UPC E ...

Page 161: ...ither of the bar codes shown below Note UPC E1 is not a UCC Uniform Code Council approved symbology EAN 8 JAN 8 Select an option by scanning either of the bar codes shown below Enable UPC E1 Disable UPC E1 Enable EAN 8 JAN 8 Disable EAN 8 JAN 8 ...

Page 162: ...ect an option by scanning either of the bar codes shown below Bookland EAN Select an option by scanning either of the bar codes shown below Enable EAN 13 JAN 13 Disable EAN 13 JAN 13 Enable Bookland EAN Disable Bookland EAN ...

Page 163: ...s The UPC EAN JAN symbol is decoded and the supplemental bar code is ignored Autodiscriminate UPC EAN JAN Supplementals When this option is selected you must assign a value to the Decode UPC EAN Supplemental Redundancy parameter A value of 5 or more is recommended Enable 378 379 Supplemental Mode The scanner will identify supplementals for EAN 13 JAN 13 bar codes that start with a 378 or 379 prefi...

Page 164: ...Decode UPC EAN JAN only with Supplementals Ignore Supplementals Autodiscriminate UPC EAN JAN Supplementals Enable 378 379 Supplemental Mode Enable 978 Supplemental Mode Enable Smart Supplemental Mode Cancel ...

Page 165: ...ted To begin setting the decode redundancy value scan this bar code Next scan two numeric bar codes that correspond to the desired value using the Imager Keypad Number Symbols page 5 81 Single digit numbers must have a leading zero To correct an error or change a selection scan Cancel on the Imager Keypad Number Symbols page Transmit UPC A Check Digit This parameter determines whether the symbol w...

Page 166: ...her of the bar codes shown below Transmit UPC E1 Check Digit This parameter determines whether the symbol will be transmitted with or without the UPC E1 check digit Select an option by scanning either of the bar codes shown below Enable Transmit UPC E Check Digit Disable Transmit UPC E Check Digit Enable Transmit UPC E1 Check Digit Disable Transmit UPC E1 Check Digit ...

Page 167: ...ers are considered part of the symbol Data is sent to the host in the following format Select an option by scanning one of the bar codes shown below No Preamble data System Character schar data System Character and Country Code country code schar data No Preamble System Character System Character and Country Code 0 for USA ...

Page 168: ...ers are considered part of the symbol Data is sent to the host in the following format Select an option by scanning one of the bar codes shown below No Preamble data System Character schar data System Character and Country Code country code schar data No Preamble System Character System Character and Country Code 0 for USA ...

Page 169: ...ers are consid ered part of the symbol Data is sent to the host in the following format Select an option by scanning one of the bar codes shown below No Preamble data System Character schar data System Character and Country Code country code schar data No Preamble System Character System Character and Country Code 0 for USA ...

Page 170: ...by scanning either of the bar codes shown below Convert UPC E1 to UPC A When this parameter is enabled UPC E1 zero suppressed decoded data is converted to UPC A format before transmis sion After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit etc When disabled UPC E1 zero suppressed decoded data is transmitted without conversion Select ...

Page 171: ...aces UPC EAN Coupon Code The UCC Coupon Extended Code is an additional bar code adjacent to a UCC Coupon Code To enable or disable UCC Coupon Extended Code scan the appropriate bar code below When enabled this parameter decodes UPC A bar codes starting with digit 5 EAN 13 bar codes starting with digit 99 and UPC A EAN 128 Coupon Codes UPCA EAN 13 and EAN 128 must be enabled to scan all types of Co...

Page 172: ...et this parameter by scanning either of the bar codes shown below UCC EAN 128 Set this parameter by scanning either of the bar codes shown below Enable Code 128 Disable Code 128 Enable UCC EAN 128 Disable UCC EAN 128 ...

Page 173: ...tenation of the ISBT data Set this parameter by scanning either of the bar codes shown below Code 39 Note This parameter must be enabled when Convert Code 39 to Code 32 is to be enabled Note Set this parameter by scanning either of the bar codes shown below Enable ISBT 128 Disable ISBT 128 Enable Code 39 Disable Code 39 ...

Page 174: ...of the bar codes shown below Convert Code 39 to Code 32 Note Code 39 must be enabled in order for this parameter to function Note When parameter Code 32 Prefix is to be enabled this Convert Code 39 to Code 32 Italian Pharmacy Code parameter must also be enabled Note Set this parameter by scanning either of the bar codes shown below Enable Trioptic Code 39 Disable Trioptic Code 39 Enable Convert Co...

Page 175: ...ds the prefix character A to all Code 32 bar codes Note When enabled Convert Code 39 to Code 32 parameter must also be enabled Set this parameter by scanning either of the bar codes shown below Enable Code 32 Prefix Disable Code 32 Prefix ...

Page 176: ...umber Symbols page Two Discrete Lengths Parameter L2 This option decodes only those codes containing two selected lengths For example when you want to scan only Code 39 symbols containing 2 or 14 characters scan the following bar code and then 0 2 1 and 4 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting two discrete lengths scan this Two Discrete Lengths bar code Next sc...

Page 177: ... complies with specified check digit algorithms Only Code 39 symbols which include a Modulo 43 check digit are decoded when this parameter is enabled When Transmit Code 39 Check Digit is enabled this parameter must be enabled too Enable this feature if the code 39 bar codes contain a Modulo 43 check digit Set this parameter by scanning either of the bar codes shown below Enable Code 39 Check Digit...

Page 178: ...hown below When enabled the ASCII character set assigns a code to letters punctuation marks numerals and most control key strokes on the keyboard The first 32 codes are non printable and are assigned to keyboard control characters such as Backspace and Return or Enter The other 96 are called printable codes because all but Space and Delete produce visible characters Code 39 Full ASCII interprets t...

Page 179: ...titled ASCII Character Equivalents page 9 2 One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only Code 93 symbols containing 14 characters scan the Code 93 One Discrete Length bar code and then 1 and 4 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting one discrete length scan this Code 93 ...

Page 180: ...Imager Keypad Number Symbols page Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only Code 93 symbols containing between 4 and 12 characters scan the Code 93 Length Within Range bar code and then 0 4 1 and 2 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting lengths within a range scan this...

Page 181: ...tled ASCII Character Equivalents page 9 2 One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only Code 11 symbols containing 14 characters scan the Code 11 One Discrete Length bar code and then 1 and 4 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting one discrete length scan this Code 11 On...

Page 182: ...ger Keypad Number Symbols page 5 81 Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only Code 11 symbols containing between 4 and 12 characters scan the Code 11 Length Within Range bar code and then 0 4 1 and 2 bar codes To begin setting lengths within a range scan this Code 11 Length Within Range bar code Next scan...

Page 183: ... check digit algorithm Note Enable Code 11 Check Digit Verification when Transmit Code 11 Check Digits is enabled Set this parameter by scanning one of the bar codes shown below Transmit Code 11 Check Digits Code 11 Check Digit Verification must be enabled for this parameter to function Disable Code 11 Check Digit Verification One Check Digit Two Check Digits Transmit Enable Code 11 Check Digits D...

Page 184: ... a complete scan yielding less data than is encoded in the bar code To prevent this select specific lengths using I 2 of 5 One Discrete Length and I 2 of 5 Two Discrete Lengths for I 2 of 5 applications One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only I 2 of 5 symbols containing 14 characters scan the I 2 of 5...

Page 185: ... Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only I 2 of 5 symbols containing between 4 and 12 characters scan the I 2 of 5 Length Within Range bar code and then 0 4 1 and 2 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting lengths within a range scan this I 2 of 5 Length within Range b...

Page 186: ...g one of the bar codes shown below Transmit I 2 of 5 Check Digit When enabled the check digit is transmitted with the data Parameter setting for I 2 of 5 Check Digit Verification has no effect on this parameter value Set this parameter by scanning either of the bar codes shown below Disable I 2 of 5 Check Digit Verification USS Uniform Symbology Specification OPCC Optical Product Code Council Enab...

Page 187: ...led the parameter converts a 14 character I 2 of 5 bar code into EAN 13 and transmits it to the host as EAN 13 Set this parameter by scanning either of the bar codes shown below Discrete 2 of 5 DTF When enabled Discrete 2 of 5 D 2 of 5 symbols will be scanned decoded and transmitted Set this parameter by scanning either of the bar codes shown below Enable Convert I 2 of 5 to EAN 13 Disable Convert...

Page 188: ...ining 14 characters scan the D 2 of 5 One Discrete Length bar code and then 1 and 4 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting one discrete length scan this D 2 of 5 One Discrete Length bar code Next scan two numeric bar codes that correspond to the desired value Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel ...

Page 189: ...umbers must have a leading zero To correct an error or to change a selection scan Cancel on the Imager Keypad Number Symbols page Any Length This option decodes D 2 of 5 bar codes containing any number of characters Selecting this option may lead to misdecodes for D 2 of 5 codes See next note To set any length scan this D 2 of 5 Any Length bar code Note Due to the construction of the D2 of 5 symbo...

Page 190: ...n enabled the start and stop characters are stripped from the bar code and a space is inserted after the 1st 5th and 10th characters of a 14 character Codabar symbol Set this parameter by scanning either of the bar codes shown below Note Symbol length does not include start and stop characters Enable Codabar Disable Codabar Enable CLSI Editing Disable CLSI Editing ...

Page 191: ...le titled ASCII Character Equivalents page 9 2 One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only Cod abar symbols containing 14 characters scan the Codabar One Discrete Length bar code and then 1 and 4 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting one discrete length scan this Coda...

Page 192: ...r Symbols page Length Within Range This option decodes a code type within a specified minimum and maximum range For example when you want to scan only Codabar symbols containing between 4 and 12 characters scan the Codabar Length Within Range bar code and then 0 4 1 and 2 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting lengths within a range scan this Codabar Length Wit...

Page 193: ...reted as a complete scan yielding less data than is encoded in the bar code To prevent this select specific lengths using MSI One Discrete Length and MSI Two Discrete Lengths for MSI applications Note One Discrete Length Parameter L1 This option decodes only those codes containing a selected length For example when you want to scan only MSI symbols containing 14 characters scan the MSI One Discret...

Page 194: ...een 4 and 12 characters scan the MSI Length Within Range bar code and then 0 4 1 and 2 bar codes using the Imager Keypad Number Symbols page 5 81 To begin setting lengths within a range scan this MSI Length Within Range bar code Next scan numeric bar codes that correspond to the desired value Single digit numbers must have a leading zero To correct an error or to change a selection scan Cancel on ...

Page 195: ...cally transmitted with the data Note When Two MSI Check Digits is selected an MSI Check Digit Algorithm must also be selected Note Set the number of check digits to be included with the bar code by scanning either of the bar codes shown below Transmit MSI Check Digit When enabled the check digit is transmitted with the data Set this parameter by scanning either of the bar codes shown below One MSI...

Page 196: ...rification is required to ensure integrity Either of the two following algorithms may be selected Set this parameter by scanning either of the bar codes shown below Postal Codes Note The default value for all Postal Code symbologies is Enabled For best performance when reading a specific postal symbology all other postal symbologies should be disabled US Postnet To enable or disable US Postnet sca...

Page 197: ... Planet To enable or disable US Planet scan the appropriate bar code UK Postal To enable or disable UK Postal scan the appropriate bar code Enable US Planet Disable US Planet Enable UK Postal Disable UK Postal ...

Page 198: ...her to transmit UK Postal data with or without the check digit Japan Postal To enable or disable Japan Postal scan the appropriate bar code Transmit UK Postal Check Digit Do Not Transmit UK Postal Check Digit Enable Japan Postal Disable Japan Postal ...

Page 199: ...ble or disable Australian Postal scan the appropriate bar code Dutch Postal To enable or disable Dutch Postal scan the appropriate bar code Enable Australian Postal Disable Australian Postal Enable Dutch Postal Disable Dutch Postal ...

Page 200: ...to transmit US Postal data with or without the check digit 4 State Postal To enable or disable 4 State Postal scan the appropriate bar code Transmit US Postal Check Digit Do Not Transmit US Postal Check Digit Enable 4 State Postal Disable 4 State Postal ...

Page 201: ...GS1 DataBar RSS GS1 DataBar Omnidirectional RSS 14 To enable or disable GS1 DataBar Omnidirectional RSS 14 scan the appropriate bar code See Also Convert GS1 DataBar RSS to UPC EAN page 5 68 GS1 DataBar Limited RSS Limited To enable or disable GS1 DataBar Limited RSS Limited scan the appropriate bar code See Also Convert GS1 DataBar RSS to UPC EAN page 5 68 Enable GS1 DataBar Omnidirectional RSS 1...

Page 202: ... DataBar Limited RSS Limited symbols encoding a single zero as the first digit and report the bar code as EAN 13 For bar codes beginning with two or more zeros but not six zeros this parameter strips the leading 0100 and reports the bar code as UPC A The UPC A Preamble parameter that transmits the system character and country code applies to con verted bar codes Note that neither the system charac...

Page 203: ...codes to enable or disable Composite bar codes of type CC C Composite CC A B Scan one of the following bar codes to enable or disable Composite bar codes of type CC A B Enable Composite CC C Disable Composite CC C Enable Composite CC A B Disable Composite CC A B ...

Page 204: ...8 Emulation Mode Enable Composite TLC 39 Disable Composite TLC 39 UPC Never Linked Transmit UPC bar codes regardless of whether a 2D symbol is detected UPC Always Linked Transmit UPC bar codes and the 2D portion If 2D is not present the UPC bar code does not transmit Autodiscriminate UPC Composites The decoding engine determines if there is a 2D portion then transmits the UPC as well as the 2D por...

Page 205: ... for UCC EAN Composite Codes 2D Symbologies Aztec To enable or disable Aztec scan the appropriate bar code below Enable UCC EAN Code 128 Emulation Mode for UCC EAN Composite Codes Disable UCC EAN Code 128 Emulation Mode for UCC EAN Composite Codes Enable Aztec Disable Aztec ...

Page 206: ...r controls the setting of the Aztec Inverse decoder Scan the appropriate bar code below PDF417 To enable or disable PDF417 scan the appropriate bar code below Regular Only Inverse Only Inverse Auto Detect Enable PDF417 Disable PDF417 ...

Page 207: ... enabled for this parameter to work If Code 128 Emulation is enabled these MicroPDF417 symbols are transmitted with one of the following prefixes C1 if the first codeword is 903 907 912 914 915 C2 if the first codeword is 908 or 909 C0 if the first codeword is 910 or 911 If disabled they are transmitted with one of the following prefixes L3 if the first codeword is 903 907 912 914 915 L4 if the fi...

Page 208: ...x scan the appropriate bar code below Data Matrix Inverse This parameter controls the setting of the Data Matrix inverse decoder Scan the appropriate bar code below Enable Data Matrix Disable Data Matrix Regular Only Inverse Only Inverse Auto Detect ...

Page 209: ...xicode To enable or disable Maxicode scan the appropriate bar code below MicroQR To enable or disable MicroQR scan the appropriate bar code below Enable Maxicode Disable Maxicode Enable MicroQR Disable MicroQR ...

Page 210: ...le QR Code scan the appropriate bar code below QR Inverse This parameter controls the setting of the QR Inverse decoder Scan the appropriate bar code below Enable QR Code Disable QR Code Regular Only Inverse Only Inverse Auto Detect ...

Page 211: ...wing code types must be successfully read twice before being decoded Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded The following codes must be read three times Redundancy Level 4 The following code types must be successfully read three times before being decoded Code Type Code Length Codabar 8 characters or less MSI 4 characters or less...

Page 212: ...5 78 Redundancy Level 1 Redundancy Level 2 Redundancy Level 3 Redundancy Level 4 ...

Page 213: ...te in its most aggressive state while providing sufficient security in decoding most in spec bar codes Security Level 1 Select this option if misdecodes occur This default setting should eliminate most misdecodes Security Level 2 Select this option if Security level 1 fails to eliminate misdecodes Security Level 3 If Security Level 2 was selected and misdecodes still occur select this security lev...

Page 214: ...ll Due to various bar code printing technologies this gap can grow larger than the maximum size allowed preventing the decoder from decoding the symbol If this problem occurs scan the Large Intercharacter Gaps parameter to tolerate these out of specification bar codes Normal Intercharacter Gaps Large Intercharacter Gaps ...

Page 215: ...ad with decimal values 0 through 9 Each label should be scanned individually Use these numeric value symbols to enter numeric input in the course of performing an imager engine system configuration To correct an error or change a selection scan Cancel then scan a desired bar code 0 1 2 3 4 5 ...

Page 216: ...5 82 6 7 8 9 Cancel ...

Page 217: ...page 10 1 for upgrade arrangements Updating the Module Firmware 1 Remove the battery pack from the Bluetooth Ring Scanner module 2 Disconnect the ring decoder cable 3 Connect the USB end of the firmware update cable to the USB port on a computer 4 Connect the I O end of the firmware update cable to the I O connector on the Bluetooth Ring Scanner module 5 Insert a fully charged battery pack into th...

Page 218: ... or by removing the cable before the update is complete the original firmware will be destroyed and the Bluetooth Ring Scanner will not be able to run in normal operation mode If this event occurs the utility on the host computer indicates that the firmware upgrade was not successful This condition can be recovered by repeating the firmware update procedure Install BlueCore Device Update Wizard an...

Page 219: ...date Wizard 4 Insert the update cable into the Bluetooth module to be updated The module should power up indicated by a beep sequence and the blue LED illuminating then flashing 5 Insert the USB update cable into one of the host PC USB ports The PC should recognize that a USB device has been detected 6 A message will appear stating the USB device driver needs to be installed on the PC 7 The Window...

Page 220: ... Finish on the next dialog box 13 Navigate to the Windows Device Manager screen On Windows XP devices one path to the Device Manager screen is Start Control Panel System Hardware tab and click the Device Manager button Shown below is a sample of a Device Manager screen 14 Click the plus sign next to Universal Serial Bus controllers Verify the BTRS Ringscanner in DFU mode is present Close all open ...

Page 221: ...ior to actual bar code decoding with a duration from 1 sec to 8 sec The following good scan and decode ranges decode zones are related to a specific scan engine either integrated or connected to your mobile device If you do not see your type of scan engine listed you may be using a tethered Bluetooth bar code scanner or a serial port connected bar code scanner these types of external scanners are ...

Page 222: ...ges Guaranteed Working Ranges Near Far Near Far 5 0 mil 3 5 in 8 9 cm 7 0 in 17 8 cm 4 25 in 10 8 cm 6 0 in 15 2 cm 6 67 mil 3 75 in 9 5 cm 6 0 in 15 2 cm 4 5 in 11 4 cm 5 75 in 14 6 cm 7 5 mil 2 75 in 7 0 cm 7 75 in 19 7 cm 3 5 in 8 9 cm 6 5 in 16 5 cm 10 mil 3 25 in 8 3 cm 7 25 in 18 4 cm 4 0 in 10 2 cm 6 5 in 16 5 cm 13 mil 2 25 in 5 7 cm 8 75 in 22 2 cm 3 0 in 7 6 cm 7 0 in 17 8 cm 15 mil 7 5 ...

Page 223: ... 0 cm 10 0 in 25 4 cm 3 5 in 8 9 cm 8 5 in 21 6 cm 10 mil 3 25 in 8 3 cm 10 25 in 26 0 cm 4 0 in 10 2 cm 9 5 in 24 1 cm 13 mil 2 25 in 5 7 cm 16 0 in 40 6 cm 3 0 in 7 6 cm 13 in 33 0 cm 15 mil 13 75 in 34 9 cm 12 75 in 32 4 cm 20 mil 21 5 in 51 6 cm 17 0 in 43 2 cm Symbol Density Focus Position Typical Working Ranges Near Far 5 0 mil Near Far 3 5 in 8 9 cm 6 5 in 16 5 cm 5 875 in 14 1 cm N A 6 67 ...

Page 224: ...7 4 ...

Page 225: ...entilated Is not in high traffic areas Locates or orients the AC cord so that it will not be stepped on tripped over or subjected to damage or stress Has enough clearance to allow easy access to the power port on the back of the device Is protected from rain dust direct sunlight or inclement weather This device is intended for indoor use only and requires an indoor AC power source The charger is n...

Page 226: ... the Li Ion battery pack in direct sunlight or anywhere the battery pack cannot cool down If the Li Ion battery pack is hot after removal from the Bluetooth Ring Scanner allow it to cool at room temperature or in a cool air stream before placing it in the charger Do not dispose of Li Ion batteries into a fire Burning will generate hazardous vapors and may cause the battery to explode Failure to ob...

Page 227: ... life end of life occurs after 500 charge discharge cycles it must be replaced Battery packs do not need to be fully discharged between charge cycles While charging the charger and battery pack will generate enough heat to feel warm This is normal and does not indicate a problem Eight Bay Battery Charger Front View Place the charger on a horizontal hard surface or fasten securely to a wall using t...

Page 228: ...S models a power cord is required 1 Plug the 2 prong cable into an AC wall outlet 2 Firmly press the female end of the power cable into the male connector on the AC power adapter 3 AC power is now being applied to the power adapter Setup Prerequisite The AC Adapter is assembled and receiving AC power Do not insert battery packs until the battery charger has finished powering up Battery charger 1 B...

Page 229: ...mly and pull it straight up and out of the charging pocket Interpreting the Charging Pocket LEDs The status of the charge operation is indicated by the color of the LED for each charging pocket RED Continuous on any charge pocket Continuous red means the battery pack is charging RED FLASHING on all charge pockets Battery charger fault or failure GREEN on any charge pocket Continuous green means th...

Page 230: ...serting the battery incorrectly could result in damage to the battery pack or the charger Caution Do not slam the battery pack into the charging pocket Damage may result When preparing the battery pack for insertion into the battery charging pocket hold the battery with its three charging con tacts in line with the three charging contacts in the charging pocket use the direction of the arrow on th...

Page 231: ...ing the Charging LED The status of the charge operation is indicated by the color of the LED RED The battery pack is charging GREEN The battery pack is charged Charge Timer The Single bay charger does not contain a timer The charger provides a soft charge mode for deeply discharged batteries a fast charge mode and a constant charge mode that maintains power levels in charged batteries Battery char...

Page 232: ...ugged into a live outlet battery pack is inserted but RED LED is OFF and no other LEDs are on or all LEDs are off New battery pack same result Contact Customer Support page 10 1 for replacement options When you first put a fully charged battery pack in the charging pocket the RED LED comes on indicating the battery pack is charging During the first few minutes the battery charger checks the batter...

Page 233: ...promptly and properly The best way to dispose of used batteries is to recycle them Battery recycling facilities recover the Nickel Lithium or Lead from old batteries to manufacture new batteries Use only mild detergent with a slightly damp cloth to clean the outside of the battery Do not use solvents or flammable cleaners Allow the case to dry fully before using again Do not allow cleaning agents ...

Page 234: ... charger rather than hold its charge Battery packs may leak up to 1 mA current through the battery contacts when left in an unpowered charger pocket Service There are no user serviceable parts in the Lithium Ion Battery Pack Contact Customer Support page 10 1 for battery dis posal and replacement options ...

Page 235: ...ner Height 0 75 1 90cm x Width 1 75 4 44cm x Length 2 9 7 4cm Module Weight 2 15oz 60 9g with battery 1 60oz 45g without battery 4 05 4 15oz 114g 117g with battery and scanner Ring Scanner 1 75oz 49 6g Ring Imager 1 85oz 52 4g Battery Li Ion 3 7v 750mAh with a 500 charge discharge life cycle Operating Temperature 4 F to 122 F 20 C to 50 C Storage Temperature 40 F to 158 F 40 C to 60 C Water and Du...

Page 236: ...batteries 9 10oz 258g With 8 batteries 13 85oz 392g AC Adapter 6 40oz 181g Without battery 2 05oz 58g With battery 2 75oz 78g With battery and power plug 3 25oz 92g Power plug 0 70oz 19 8g Plug Type IEC 2 prong IEC 2 prong Length 9 23cm 2 9 7 4cm with 2 prong plug 4 10cm Width 3 25 8 25cm 1 9 4 8cm Height 1 25 3 17cm with batteries 2 5 6 3cm 1 15 2 92cm with battery 2 25 5 71cm Mounting Distance b...

Page 237: ...L 1029 lDh C CTRL 1030 lEh D CTRL 6 1031 lFh E CTRL 1032 20h Space Space 1033 21h A 1034 22h B 1035 23h C 1036 24h D 1037 25h E 1038 26h F 1039 27h G 1040 28h H 1041 29h I 1042 2Ah J 1043 2Bh K 1044 2Ch L 1045 2Dh 1046 2Eh 1047 2Fh 1048 30h 0 0 1049 31h 1 1 1050 32h 2 2 1051 33h 3 3 1052 34h 4 4 1053 35h 5 5 1054 36h 6 6 1055 37h 7 7 1056 38h 8 8 1057 39h 9 9 1058 3Ah Z Scan Value Hex Value Full A...

Page 238: ... 1075 4Bh K K 1076 4Ch L L 1077 4Dh M M 1078 4Eh N N 1079 4Fh O O 1080 50h P P 1081 51h Q Q 1082 52h R R 1083 53h S S 1084 54h T T 1085 55h U U 1086 56h V V 1087 57h W W 1088 58h X X 1089 59h Y Y 1090 5Ah Z Z 1091 5Bh K 1092 5Ch L 1093 5Dh M 1094 5Eh N 1095 5Fh O 1096 60h W 1097 61h A a 1098 62h B b 1099 63h C c 1100 64h D d 1101 65h E e Scan Value Hex Value Full ASCII Code 39 Encode Char Keystrok...

Page 239: ...6Dh M m 1110 6Eh N n 1111 6Fh O o 1112 70h P p 1113 71h Q q 1114 72h R r 1115 73h S s 1116 74h T t 1117 75h U u 1118 76h V v 1119 77h W w 1120 78h X x 1121 79h Y y 1122 7Ah Z z 1123 7Bh P 1124 7Ch Q 1125 7Dh R 1126 7Eh S 1127 7Fh Undefined Scan Value Hex Value Full ASCII Code 39 Encode Char Keystroke ...

Page 240: ...9 6 ...

Page 241: ...r party B excessive voltage or current supplied to or drawn from the interface connections C static electricity or electro static discharge D operation under conditions beyond the specified operating parameters or E repair or service of the product by anyone other than HII or its authorized representatives This warranty shall extend from the time of shipment for the duration published by HII for t...

Page 242: ...HII extends these warranties only to the first end users of the products These warranties are non transferable The duration of the limited warranty for the Bluetooth Ring Scanner Module is 1 year The duration of the limited warranty for the Bluetooth Ring Scanner Module Battery Charger is 1 year The duration of the limited warranty for the Bluetooth Ring Scanner Module 750mAh Li Ion Battery is 6 m...

Page 243: ......

Page 244: ... Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 8650 UG Rev A 1 15 ...

Reviews: