Figure 5.5

Figure 5.8

Figure 5.9

Figure 5.4

Figure 5.7

Figure 5.6

Blade Screw

Blade Washer

Blade Arm

Light Kit Screw

Glass Bowl

Raised Bump

Groove

Bulb

Blade Arm

Motor Screw

Fitter 

Plate 

Screw

Light 

Pan

9-pin 

Connector

Blade

4. Partially insert three blade screws, along with the blade washers, through the blade and into the blade arm. Tighten each 

blade screw, starting with the one in the middle. Repeat this step for the remaining blades and blade arms (Figure 5.4). 

5. Remove the ten motor screws from the motor assembly. Then install the blade arms into the underside of the motor assembly 

using the motor screws. Completely secure each blade arm to motor assembly before moving to the next (Figure 5.5). 

6. Remove one fitter plate screw from the fitter plate and loosen, but do not remove the other three. Insert the 9-pin connector 

from the motor assembly through the hole in the light pan. Align the three key slots in the light pan with the loosened fitter 

plate screws. Place the light pan over the three screws and turn the light pan clockwise. Re-install the previously removed 

light pan screw, and tighten all four screws securely (Figure 5.6). 

7.Remove one of the light pan screws from the light pan, and loosen (do not remove) the other two screws. Then, connect the 

9-pin connector from the fan to the 9-pin connector from the light kit. Then, lift the two key hole slots in the light kit over the 

loosened light pan screws. Turn the light kit in a clockwise direction and reinstall the previously removed light pan screw. 

Tighten all three screws securely (Figure 5.7).  

8. Install the E26-base B10 bulbs in the sockets of the light kit (Figure 5.8).

9. Align the grooves on the glass bowl with the raised bumps on the light kit. Then, turn the glass bowl in a clockwise direction 

until the glass is secure (Figure 5.9).

Summary of Contents for 50610

Page 1: ...Bonterra Ceiling Fan User Guide Model 50610 50690 Home ...

Page 2: ...nrod Pin Yoke Cover Remote Pack Bulb x 3 Yoke Closemount Screw x 3 Set Screw x 2 Motor Assembly Blade x 5 Blade Arm x 5 Light Pan Light Kit Glass Bowl Blade Balancing Kit Blade Washer x 15 Blade Screw x 15 Wire Connector Note Some extra hardware may be included The quantity listed above is the number required for installation ...

Page 3: ...larger than 12 gauge and or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use WARNING To reduce the risk of fire electric shock or personal injury do not bend the blade arms when installing them balancing the blades or cleaning the fan Do not insert objects between the rotating fan blades WARNING To reduce the r...

Page 4: ...ings A longer downrod is sometimes necessary to ensure proper blade clearance Ensure the ceiling angle is not steeper than 10 degrees Flushmount Installation not available for this model Closemount Installation best suited for ceilings 8 feet or lower 3 Choose a suitable location Ensure the blades will be at least 30 inches from any obstructions Also check the downrod length to ensure the blades w...

Page 5: ...downrod measure 8 inches of wire Cut off the excess wire using wire cutters not included Then strip 1 2 inch of insulation from the end of each wire strand Figure 3 4 5 Install the ball end of the downrod into the opening of the mounting bracket WARNING Failure to align the slot in the ball with the tap on the mounting bracket may cause the fan to fall which could result in injury or death Then in...

Page 6: ...e 5 2 3 Secure the canopy with the two previously removed mounting bracket screws Tighten all the mounting bracket screws securely Figure 5 3 Canopy Cover Closemount Screw Mounting Bracket Canopy Canopy Canopy Hook CLOSEMOUNT INSTRUCTIONS optional 1 Remove the canopy cover from the bottom of the canopy Figure 4 1 2 Remove the three Phillips head closemount screws from the top of the motor assembly...

Page 7: ...ther three Insert the 9 pin connector from the motor assembly through the hole in the light pan Align the three key slots in the light pan with the loosened fitter plate screws Place the light pan over the three screws and turn the light pan clockwise Re install the previously removed light pan screw and tighten all four screws securely Figure 5 6 7 Remove one of the light pan screws from the ligh...

Page 8: ...ce In warmer weather push the reverse switch left which will result in downward airflow creating a wind chill effect In cooler weather push the reverse switch right and the fan to low which will result in upward airflow that can help move stagnant hot air off the ceiling area Figure 6 2 10 Remove the battery door from the back of the remote Insert the battery from the remote pack into the remote e...

Page 9: ...the power off and check all connections at the ceiling outlet box 1 Power surge may have cleared the memory and remote needs to be resynced to the receiver Syncing instructions Turn off the main power then turn it back on Within 30 seconds press and hold the high and low speed buttons on the remote at the same time for 5 seconds The LED indicator will flash 3 times signaling a successful synchroni...

Page 10: ...itation of incidental or consequential damages so this limitation may not apply to you If the original purchaser ceases to own the fan this warranty is voided Should the purchaser encounter a problem with your fan related to defects in workmanship or materials within the warranty period associated with the defective part HKC agrees to replace the defective part without charge or at its option to r...

Reviews: