TROUBLESHOOTING

The fan does not 

move.

The fan is noisy.

The fan wobbles 

excessively.

The fan operates 

correctly but the lights 
are not working

Remote does not 

work.

1. Firmly push the reverse switch completely left or right.

2. Make sure the wall switch is turned on.

3. Turn the power on or check the fuse (breaker).

4. Turn the power off and check all connections at the ceiling outlet box.

1. Check and tighten all screws that hold the fan blades to the blade arms and the motor.

2. Replace the cracked blade.

3. Do not use a full range dimmer switch to control the fan speed.

4. Ensure the outlet box is secured to the building structure.

5. Ensure the mounting bracket is secured to the outlet box and that the screws are tight.

1. Ensure the single-pin connectors are properly secured.

2. Turn the power off and check all connections at the ceiling outlet box.

1. Power surge may have cleared the memory and remote needs to be resynced to the receiver. 

Syncing instructions:

 Turn off the main power, then turn it back on. Within 30 seconds, press 

and hold the high and low speed buttons on the remote at the same time for 5 seconds. The LED 

indicator will flash 3 times, signaling a successful synchronization. Once complete, the fan will start 

on the low speed with the light (if applicable) off.

2. Insert new 12V battery in battery compartment of the remote.

3. If there are several remote fans in close proximity, turn the power off to those fans and re-sync 

the fan.

1. Check and tighten all screws that hold the fan blades to the blade arms and the blade arms to the 

motor.

2. Switch one blade with a blade from the opposite side, or balance the fan using the blade 

balancing kit.

3. Turn off the power. Loosen the canopy and verify that the mounting bracket is secure to the 

electrical outlet box. The bracket must be flush without movement against the outlet box. Verify 

the outlet box is secure.

4. Use a longer downrod (sold separately) or move the fan to another location.

5. Lift up the yoke cover and tighten the set screws on the yoke until secure.

PROBLEM

CORRECTIVE ACTION

If you experience any faults, please check the Troubleshooting section below. If a problem cannot be remedied or you are 

experiencing difficulty in installation, please contact Customer Service: 1-877-361-3883.

Warning:

 Shut off the power supply before you begin any maintenance task. 

Summary of Contents for 50608

Page 1: ...Xerxes Ceiling Fan User Guide Model 50608 50609 Home ...

Page 2: ...Blade Arm x 8 Blade x 8 Yoke Cover Set Screw x 2 Yoke Closemount Screw x 3 Motor Assembly Fitter Plate Fitter Plate Screw x 3 Light Kit Lens Cover Remote Kit Blade Balancing Kit Blade Screw x 24 Screw Cap x 24 Wire Connector x 1 Note Some extra hardware may be included The quantity listed above is the number required for installation ...

Page 3: ...larger than 12 gauge and or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use WARNING To reduce the risk of fire electric shock or personal injury do not bend the blade arms when installing them balancing the blades or cleaning the fan Do not insert objects between the rotating fan blades WARNING To reduce the r...

Page 4: ...egrees Flushmount Installation not available for this model Closemount Installation best suited for ceilings 8 feet or lower 3 Choose a suitable location Ensure the blades will be at least 30 inches from any obstructions Also check the downrod length to ensure the blades will be at least 7 feet above the floor Figure 1 3 1 Loosen all four mounting bracket screws and completely remove the two screw...

Page 5: ... downrod measure 8 inches of wire Cut off the excess wire using wire cutters not included Then strip 1 2 inch of insulation from the end of each wire strand Figure 3 4 5 Install the ball end of the downrod into the opening of the mounting bracket Figure 3 5 WARNING Failure to align the slot in the ball with the tap on the mounting bracket may cause the fan to fall which could result in injury or d...

Page 6: ...o connect household supply and fan wires according to the diagram Figure 5 1 and the following steps Connect the green wire from the downrod and mounting bracket to the Bare Green ground supply wire Note Closemount installation does not use the downrod so there will only be two Green wires to connect Connect the White wire with red label from the receiver to the White neutral supply wire Connect t...

Page 7: ... the single pin connector from the fitter plate to the single pin connector from the light kit Blue to Black and White to White Align the slotted holes in the light kit with the loosened screws in the fitter plate Turn light kit clockwise and replace the previously removed fitter plate screw Tighten all screws Figure 5 6 7 Attach the lens cover to the light kit by twisting the lens cover tightly i...

Page 8: ...l to dim or brighten the lights Non dimmable Bulbs Turns the lights on and off Note The dimmer function does not work with CFL bulbs F D CFL Switch Switch should be set to D to correspond with the included LED bulbs which will enable the dimming function Flip to CFL if you change to non dimmable bulbs Figure 6 1 2 Use the reverse switch located on the top of the motor assembly to optimize your fan...

Page 9: ...ttons on the remote at the same time for 5 seconds The LED indicator will flash 3 times signaling a successful synchronization Once complete the fan will start on the low speed with the light if applicable off 2 Insert new 12V battery in battery compartment of the remote 3 If there are several remote fans in close proximity turn the power off to those fans and re sync the fan 1 Check and tighten a...

Page 10: ...itation of incidental or consequential damages so this limitation may not apply to you If the original purchaser ceases to own the fan this warranty is voided Should the purchaser encounter a problem with your fan related to defects in workmanship or materials within the warranty period associated with the defective part HKC agrees to replace the defective part without charge or at its option to r...

Reviews: