SOLDERING

CAUTION

PRODUCT DAMAGE

  Ensure iron tip is clean when soldering.

Failure to comply with these instructions may result in
product damage.

Hand Soldering

The following is recommended:

1.  Flux: Rosin Base
2.  Solder: Kester #44 60-40 rosin core, or

equivalent.

3.  Soldering Iron: Type; Weller, Model TC-552, 55

watt or equivalent.

4.  Tip Size: 3mm (.118 in.) Diameter x 30mm

(1.182 in.) long

5.  Tip Temperature: 288

°

C (550

°

F) max

6.  Terminal Contact Time: 6 seconds max.

Wave Soldering
   The following is recommended:

1.  Flux: London Chemical Co. Loncoflux - 106A35

or equivalent

2.  Preheat: Preheaters should be set to give 95 

°

C

(200 

°

F) on the top (component side) of printed

circuit board just prior to board entering the
wave. (May have to be adjusted depending
upon board thickness.)

3.  Solder Temperature: 260 

°

C (500 

°

F) max.;

preferably 252 

°

C to 260 

°

C (485 

°

F to 500 

°

F).

4.  Speed: Set conveyor speed to approximately

4.5 feet/minute (1,37 meters/minute).

5.  Printed circuit board requires rigid support

during wave soldering.

CLEANING

Hand Cleaning

Clean areas with a 50-50 mixture of isopropyl

alcohol and clean tap water. Dry in a 71 

°

C (160 

°

F)

oven for 10-15 minutes, preferably in a non-
circulating oven. This will remove all moisture from
the assembly, which must be done before electrical
testing, or application.

Machine Cleaning *

Detergent: London Chemical Company

Loncoterge 444-NRT6 or equivalent. Equipment:
Dee Electric Aqueous Cleaner or equivalent. The
following is reccommended:
1.  Wash Section: 55 

°

C (130 

°

F) maximum water

temperature, 5 to 10% maximum solution soft
water, low pressure nozzles (60 psi) on top
spray and high pressure nozzles (120 psi) on
bottom spray, conveyor speed 3 feet/minute
minimum. Recirculating tank.

2.  Rinse Section #1: Clean tap water up to 25

grains hard, salt free (to minimize possibility of
corrosion), unheated, non-recirculating, with
high pressure nozzles (120 psi).

3.  Rinse Section #2: Clean deionized water only,

high pressure nozzles (120 psi), unheated and
non-recirculating.

4.  Air Knife Section: To remove excessive amounts

of water.

5.  Drying Section: 71

°

C (160 

°

F) drying for 10-15

minutes, preferably in a non-circulating conveyor
oven.

* In this cleaning system, the detergent in the wash

section removes the non-polar contaminants, the first rinse

removes the detergent solution, and the deionized water

rinse removes the polar contaminants. The air knife and

dryer remove all the moisture from the assembly, which

must be done before electrical testing or application.

CAUTION

PRODUCT DAMAGE

  Ensure cleaner does not come in contact with sensor If

other cleaning methods are selected for removal of flux
residue.

Failure to comply with these instructions may result in
product damage.

Summary of Contents for 4AV15F

Page 1: ...ane dimensions are required to ensure operating characteristics will be met ELECTRICAL CHARACTERISTICS Catalog Listing Termination Lead Length Supply Voltage All Listings Supply Current All Listings Output Voltage All listings Output Sink Current All listings 4AV15F 24 AWG Wire 5 50 0 25 4AV16F 24 AWG Wire 7 45 0 25 4AV17F 24 AWG Wire 13 15 0 50 18 5 mA Max 40 C 15 25 mA typical 0 4 V Max 125 C 0 ...

Page 2: ...the 4AV are adjusted to produce a 100 010 dimension between the Operate point on one side of the package to the Release point on the other side The actuator can be designed to produce a specific pulse width for timing or sequencing operations MOUNTING DIMENSIONS for reference only CAUTION PRODUCT DAMAGE Do not exceed electrical specifications Do not mis wire the output connection Do not reverse su...

Page 3: ...his will remove all moisture from the assembly which must be done before electrical testing or application Machine Cleaning Detergent London Chemical Company Loncoterge 444 NRT6 or equivalent Equipment Dee Electric Aqueous Cleaner or equivalent The following is reccommended 1 Wash Section 55 C 130 F maximum water temperature 5 to 10 maximum solution soft water low pressure nozzles 60 psi on top sp...

Page 4: ...oing is Buyer s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose Specifications may change without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use While we provide application assistance personally through our li...

Reviews: