511398
301W User Manual
23
5/07
Honeywell
Using the Transmitter
How to Program the Transmitter
How to Program the Transmitter
If you initiate a programming function by pressing pushbutton 1 and
LED 2 lights, the transmitter is already performing a task. You must wait
until the transmitter is free before programming.
LEDs will blink for one minute to display network quality after the
confirmation cycles for functions related to the network. See Function 1
- Display Network Quality for a detailed description of network quality
blinking.
Powering Up the Transmitter
•
Press and hold pushbutton 1 and 2 simultaneously
•
Count 5 blinks and release
The transmitter searches for a network.
Function 1 - Display Network Quality
Enables you to consult the signal quality of the link to the network.
•
Press pushbutton 1
•
Press pushbutton 2, count 2 blinks and release.
•
Press pushbutton 1.
After the three cycle confirmation sequence, LEDs will blink for 1 minute
to display network quality:
If there is no signal, LED 1 will blink once and LED 2 remains off.
If the signal is weak, LED 1 remains off and LED 2 will blink once.
If the signal is average (or mean) the LEDs will blink in sequence: LED
1 one blink, LED 2 one blink.
If the signal is strong the LEDs will blink in sequence: LED 1 one blink,
LED 2 one blink, LED 1 one blink, LED 2 one blink.
Summary of Contents for 301W
Page 2: ......
Page 3: ...Wireless Gas Monitoring Device 301W Installation and User Manual ERP 511398 5 07 ...
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 22: ......
Page 34: ......
Page 38: ......
Page 44: ......
Page 45: ...Dispositif de détection de gaz sans fils 301W Manuel de l utilisateur ERP 511398 5 07 ...
Page 46: ......
Page 48: ......
Page 50: ......
Page 52: ......
Page 64: ......
Page 72: ......
Page 86: ......