background image

 

Panel Faults –

 If 

Panel Fault icons are displayed on the Security screen see the full Installation Guide.

 

 

AC Loss 

 

Bell Failure

 

 

Expander Failure 

 

 

Low Battery 

 

LRR Supervision Failure 

 

Max Attempts 

Exceeded 

 

Pager Failure 

 

Telco-1 Cut 

   

Telco-2 Cut

 

 

Wireless Failure

 

 

Panic

 

MOUNTING 

 

 

 

OPERATING THE TOUCHSCREEN 

For operating instructions, see the User Guide for the control 

panel used with this Touchscreen.

 

 

NOTE:

 If the touchpad is defaulted, it will cause the Z-Wave 

module to default. 

This TUXEDOW Touchscreen is for indoor use only and should be mounted at a comfortable viewing level. Avoid 

mounting in areas of high condensation such as bathrooms or in locations where bright light or sunlight shines directly 

on the screen. The Touchscreen is surface mounted directly to a wall.  

Locate the mounting plate and attach to a wall using the 4 screws provided. Insert bottom side of Touchscreen over 

the mounting plate and then click in top side to snap into place. Install the cover securing screw at the bottom of the 

device to secure. The bottom securing screw must be installed. 

To remove the Touchscreen from its mounting location, insert the end of a screwdriver between the plate and the 

touchscreen and twist to loosen and pull out to remove.  

 

WIRING 

CONNECT WIRING 

Route wiring from the controller through the opening in the 

mounting plate. 

Connect the Touchscreen in parallel with Touchscreens and 

other peripheral devices using the Touchscreen data (ECP) 

bus. If more than one Touchscreen is wired to one run, then 

the maximum lengths must be divided by the number of 

devices on the run. (e.g., the maximum length is 75 feet if two 

devices are wired on a #22 gauge run). 

Wire Gauge 

Length 

#22 gauge 

150 feet 

#20 gauge 

240 feet 

#18 gauge 

350 feet 

#16 gauge 

550 feet 

 

 

 

Refer to the control panel Installation Guide for additional  

Information. 

 

 

NOTE

: If mounting on a surface where the wire can not be 

inserted through the hole in the mounting bracket, 

knockouts have been provided to run the wires through the 

sides.  They are on all four sides. To knock them out, before 

mounting flip over the mounting plate and, using a pair of 

pliers, remove the plastic to make room for the wire.

 

This equipment should be installed in accordance with 

National Electrical Code, NFPA 70, Standard for the 

Installation of Residential Fire Warning Systems, CAN/ULC-

S540 and Chapter 2 of the National Fire Alarm Code, 

ANSI/NFPA 72 (National Fire Protection Association, 

Batterymarch Park, Quincy, MA 02269). Printed information 

describing proper installation, operation, testing, 

maintenance, evacuation planning, and repair service is to 

be provided with this equipment.  

 

 

SPECIFICATIONS 

Mechanical Specifications: 

Width: 7.91 inches (200.9mm) 

Height: 5.04 inches (128.016mm) 

Depth: .827 inches (21.00mm) 

Electrical specification: 

Backlight ON, Sound ON 

12V, 270mA 

Operating Environment: 

Humidity: 93% RH, non-condensing 

Operating Temp. 

14°F to 131°F / -10°C to 55°C  

(UL tested 32°-120°F / 0° to 49°C) 

Ship/Storage/Temp.: 40°F to 158°F / -40°C to 70°C 

Z-Wave:  

Z-Wave Plus Controller

 

Install in accordance with NFPA-70 and NFPA-72. 

Compatibility 

The table below identifies the alarm systems that the Touchscreen can 

interface with, the maximum number of Touchscreens that can be used 

with each system, and the minimum alarm panel software revision level 

for compatibility. 
 

Panel Type 

Panel Version 

Max # of 

touchscreens 

VISTA-15p 

V3 and higher 

VISTA-20p 

V3 and higher 

VISTA-21iP 

All 

VISTA-128BPT 

All 

VISTA-250BPT 

All 

VISTA-32FBPT 

All 

VISTA-128FBPT 

All 

VISTA-250FBPT 

All 

UL Note:

 For residential burglar alarm applications, the entry delay 

time shall not exceed 15 seconds, therefore use is restricted to 

compatible listed control units capable of being programmed for this 

time parameter. 

Warning: 

5G Band 5150-5250 MHz is only for indoor use. 

Warning

: Owner’s instruction notice: ’Not to be removed by anyone 

except occupant’ 

This system must be checked by a qualified technician at least once 

every three (3) years. 

 

 

UL

 

Use a UL Listed, battery-backed supply for UL installations. The battery supplies power to these keypads in case of  

AC power loss. The battery-backed power supply should have enough power to supply the keypads with the UL  

required minimum standby power time. 

IMPORTANT: 

Touchscreens powered from supplies that do not have a backup battery do not function if AC power is 

lost. Make sure to power at least one keypad in each partition from the control’s auxiliary power output or UL Listed  

battery backed up power supply. 

FEDERAL COMMUNICATIONS COMMISSION & ISED CANADA STATEMENTS 

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.  Unauthorized changes or 

modifications could void the user's authority to operate the equipment. 

CLASS B DIGITAL DEVICE STATEMENT 

This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information. 
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may 

cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the 

specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no 

guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by 

turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

•  If using an indoor antenna, have a quality outdoor antenna installed. 

•  Reorient the receiving antenna until interference is reduced or eliminated. 

•  Move the radio or television receiver away from the receiver/control panel. 

•  Move the antenna leads away from any wire runs to the receiver/control panel. 

•  Plug the receiver/control panel into a different outlet so that it and the radio or television receiver are on different branch circuits. 

•  Consult the dealer or an experienced radio/TV technician for help. 

ISED CLASS B STATEMENT 

This Class B digital apparatus complies with Canadian ICES-003. 

Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 

FCC / ISED STATEMENT 

This device complies with Part 15 of the FCC Rules, and ISED’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not 

cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation. 

Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’ISED. Son fonctionnement est soumis aux conditions suivantes: (1) Cet 

appareil ne doit pas causer d' interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception 

indésirable. 

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center Drive., Melville, NY 

11747, Ph: 516-577-2000 

Partie responsable / Émetteur de la déclaration de conformité du fournisseur : 

 

Ademco Inc., une filiale de Resideo Technologies, Inc., 2 Corporate Center Drive., 

Melville, NY 11747, Tél. 516 577-2000 

Wi-Fi

®

 and the Wi-Fi logo are registered trademarks of Wi-Fi Alliance.

 

SUPPORT, WARRANTY & PATENT INFORMATION 

For the latest warranty information, please go to: https://www.security.honeywellhome.com/warranty 

For patent information, see https://www.resideo.com/patent 

SUPPORT: 

For technical support, call 1-800-645-7492 M-F 8:30am to 5pm EST  

REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS 

USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 

 

The product should not be disposed of with other household waste. Check for the nearest authorized collection 

centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative 

consequences for the environment and human health.

 

 

Ê800-25178BÇŠ 

800-25178B   4/19   Rev B

 

 

 

2 Corporate Center Drive, Suite 100 

P.O. Box 9040 

Melville, New York 11747 

© 2019 Resideo Technologies, Inc 

 www.resideo.com

 

 

This product manufactured by Resideo and its affiliates.  

The Honeywell Home Trademark is used under license from 

Honeywell International Inc. 

 

 

 

 

Reviews: