background image

M33856

PULL HERE

TO REMOVE

PULL HERE

TO REMOVE

Finger holds

Wallplate (back view)

Thermostat

1.5  Separate Wi-Fi thermostat 

 

and its wallplate

  

 

On your new thermostat, grasp the  

 

finger holds on the top and bottom of 

 

the  wallplate with one hand and the  

 

thermostat (front) with the other 

 

hand. Pull pieces apart. 

Quick Start Guide

Wi-Fi Programmable  

Thermostat

RET97E5D Wi-Fi Series

Install your thermostat

1

Wallplate

1.6  Mount wallplate for Wi-Fi  

 

thermostat

  

 

Mount your new wallplate using screws  

 

and anchors included with the  

 

 thermostat.
 

If necessary:

 

•  Drill 3/16-in holes for drywall

 

•  Drill 7/32-in holes for plaster 

 

 

Note

You may be able to use your  

 

existing wall anchors. Hold the wallplate  

 

up to the existing anchors to check  

 

for alignment.

MCR33857

W2 G

W

Y R RC

K Y2

C

MCR33878

Y

HEAT PUMP

CONVENTIONAL

AUX/E

G

O/B

Y R RC

K L

C

C

G W

R

1.8  Install quick reference card

 

Fold quick reference card along score  

 

lines, and slide it into the slot on the  

 

back of the thermostat.

1.9  Attach thermostat to    

 wallplate

 

Align the thermostat onto  

 

 

wallplate and snap into place.

Back of thermostat

Quick 

reference 

card

MCR33858

MCR33916

M33860

HOLD

Install your thermostat.

Connect your home Wi-Fi network.

Register online for remote access.

Before you begin

1

2

3

Welcome

Getting set up and ready is simple.

View the installation video 
at honeywellhome.com/
support

Gather

•  Small screw driver

•  Thermostat ID card 

•  Your home Wi-Fi  

  network password 

This thermostat works with common 24 volt 

systems such as forced air, hydronic, heat 

pump, oil, gas, and electric. It will not work with 

millivolt systems, such as a gas fireplace, or 

with 120/240 volt systems such as baseboard 

electric heat.

1.1  Switch OFF power to your  

 

heating/cooling system

 

 

1.1a 

Important!

 To protect your  

 

 

equipment, switch OFF the  

 

 

power to your heating/cooling  

 

 

system at the breaker box or  

 

 

the system switch.

 

 

1.1b Confirm power is OFF.  

 

 

Try to turn on heating/ 

 

 

cooling equipment by  

 

 

changing temperature  

 

 

on your old thermostat.  

 

 

Your power is OFF if your  

 

 

system does not turn ON.

or

M31535

Circuit 

breaker  

box

Heating/

cooling system 

power switch

If you have an older thermostat with a 

sealed mercury tube, see warning page 

for proper disposal instructions.

1.2  Remove old thermostat  

 

faceplate and leave wires  

 connected

 

1.2a Take a picture of the  

 

 

wire connections for  

 

 

later reference.

 

1.2b If no wire is connected  

 

 

to a terminal labeled C  

 

 

or no C terminal exists  

 

 

on the old thermostat, view  

 

 

the Alternate Wiring videos at  

  honeywellhome.com/wifi-thermostat

 

Important! 

C wire is required and is the  

 

primary power source for your thermostat.  

 

Without a C wire, your thermostat will not  

 

power up.

C

C

MCR33823

C

C

MCR31537

Blank 

sticky 

tag

Terminal

designation

1.3  Label wires 

 

Do not label by wire color.  

 

Use the supplied sticky tags to label 

 

each wire as you disconnect it. Label    

 

wires according to old thermostat  

 

 

terminal designations, not by wire 

 color.

 

 

Note

If no tag matches a terminal  

 

designation, write the appropriate  

 

letter on a blank sticky tag.

1.4  Remove wallplate

 

Remove the old wallplate from 

 

the wall after all wires are 

 

labeled and disconnected.

Sticky 

tag

1.7  Connect wires

 

1.7a Starting with the C Wire, match the  

 

 

sticky tag on the wire to the terminal  

  labels.

 Important! 

C wire is required and is the  

 

primary power source. Without a C wire,  

 

your thermostat will not power up. 

 

View the Alternate Wiring videos at  

 honeywellhome.com/wifi-thermostat
 

1.7b Loosen screw, insert wire on inside  

 

 

edge of terminal, then tighten screw.

 

1.7c  Verify wire is firmly secured by gently  

 

 

pulling on wire. 

 

1.7d Repeat steps 1.7a–1.7c for all other wires.

 

1.7e Push any excess wire back into the wall  

 

 

opening after all wires are installed.

Note

:

 The wiring for your 

application might be different 

from the wiring shown above.

Labels don’t match or have heat pump system?

 

See 

User Guide

.

Remove metal jumper 

only

 if 

you have both 

R

 and 

RC

 wires

Circuit 

breaker  

box

Heating/

cooling system 

power switch

1.10  Switch heating/cooling  

 

system ON

 

Important!

 

1.10a  Verify that the C  

 

 

wire is connected at the  

 

 

thermostat and at the  

  heating/cooling 

system.

 

1.10b Make sure the heating/cooling  

 

 

system door is firmly secured.

 

1.10c  Switch power back ON for  

 

 

your heating/cooling system  

 

 

at the breaker box or its  

  power 

switch.

or

M31544

1.11  Set date and time

 

1.11a Press 

s

 or 

t

 to set clock.

 

 

1.11b Press 

Set Day

.

 

 

1.11c Press 

s

 or 

t

 to select the day 

  of 

week.

 

 

1.11d Press 

Done

 to save.

 

 

(Press and hold a 

st

 button to 

 

quickly change a setting.)

MCR33908

HOLD

MCR33909

HOLD

Turn over  

69-2802-03

Resideo Inc., 1985 Douglas Drive North, 

Golden Valley, MN 55422 
69-2802—03    M.S.  Rev. 03-19 | Printed in United States

Apple, iPhone, iPad, iPod touch and iTunes are trademarks of Apple Inc. All other trademarks are the property of their respective owners. 

©2019 Resideo Technologies, Inc. This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-633- 3991 

The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved.

www.resideo.com

HOLD

M37771

Reviews: