SENSITIVITY ADJUSTMENT
NOTE:
The PROSiXSHOCK sensitivity must be set after
mounting and enrollment. See the Controller’s instructions
for details.
The PROSiXSHOCK has the following sensitivity settings:
Maximum – Medium – Low - Lowest
1. Verify the sensitivity setting is adequate by striking the
protected surface with the soft part of your fist at the point
farthest from the device.
2. If sensitivity is adequate the red LED flashes briefly
(remove cover for easier viewing of LED).
If the LED does not flash, select the next higher
sensitivity setting and repeat from step 1.
24-HOUR ENROLLMENT DELETION AND DEFAULT
If the device is enrolled in a panel different than the intended
panel, and you are unable to delete it from the unintended
panel, reset the device to factory default setting:
1. Open the cover and remove the battery.
2. Hold down the tamper switch while reinserting the
battery. Rapid LED flashing indicates successful deletion
(LED flashes as if in enrollment mode). If LED does not
flash, delete was not successful.
3. Reattach the cover.
This procedure is available for 24 hours after enrollment with
a panel and the device remains powered (battery installed).
LED INDICATIONS
LED
Status
Rapid Flashes for about 20
seconds, then ON for 3 seconds
Power Up – Enrollment
Slow Flashes
Power Up – Device enrolled; Wall or Cover Tamper activated. To stop flashes, clear the
tamper condition by reconnecting to the mounting plate and reattaching the cover. It also
times out after 10 minutes.
ON (while in Programming Mode)
Sensor LED toggles on and off when the sensor is selected. See Sensor Location Feature.
BATTERY REPLACEMENT
•
Push the bottom latch of the mounting
bracket back to disengage it. Then slide the
back housing up and out to remove it from
the mounting bracket.
•
Slide the front and back housings in opposite
directions and pull the housings apart.
•
Remove the battery,
wait 10 seconds
, then
insert a new battery.
Recommended batteries:
Duracell DL123A, Huiderui CR123A,
Panasonic CR123A, Resideo 466
•
Place the front and back housings together
and slide them together.
BATTERY CAUTION
: Risk of fire, explosion
and burns. Do not recharge, disassemble, heat
above 212°F (100°C) or incinerate. Dispose of
used batteries properly. Keep away from
children.
NOTE
: Constant exposure to high or low
temperature or high humidity may reduce
battery life.