background image

 

SENSITIVITY ADJUSTMENT

 

NOTE: 

The PROSiXSHOCK sensitivity must be set after 

mounting and enrollment.  See the Controller’s instructions 

for details. 

 

The PROSiXSHOCK has the following sensitivity settings: 

 

Maximum – Medium – Low - Lowest 

1.  Verify the sensitivity setting is adequate by striking the 

protected surface with the soft part of your fist at the point 

farthest from the device. 

2.  If sensitivity is adequate the red LED flashes briefly 

(remove cover for easier viewing of LED). 

  If the LED does not flash, select the next higher 

sensitivity setting and repeat from step 1. 

 

 

 

24-HOUR ENROLLMENT DELETION AND DEFAULT 

If the device is enrolled in a panel different than the intended 

panel, and you are unable to delete it from the unintended 

panel, reset the device to factory default setting: 

1.  Open the cover and remove the battery. 

2.  Hold down the tamper switch while reinserting the 

battery. Rapid LED flashing indicates successful deletion 

(LED flashes as if in enrollment mode). If LED does not 

flash, delete was not successful. 

3.  Reattach the cover. 

 

This procedure is available for 24 hours after enrollment with 

a panel and the device remains powered (battery installed).

 

 

LED INDICATIONS 

 

LED

 

Status

 

Rapid Flashes for about 20 

seconds, then ON for 3 seconds

 

Power Up – Enrollment

 

Slow Flashes

 

Power Up – Device enrolled; Wall or Cover Tamper activated. To stop flashes, clear the 

tamper condition by reconnecting to the mounting plate and reattaching the cover. It also 

times out after 10 minutes.

 

ON (while in Programming Mode)

 

Sensor LED toggles on and off when the sensor is selected. See Sensor Location Feature. 

 

 

BATTERY REPLACEMENT  

  Push the bottom latch of the mounting 

bracket back to disengage it. Then slide the 

back housing up and out to remove it from 

the mounting bracket. 

 

  Slide the front and back housings in opposite 

directions and pull the housings apart.  

  Remove the battery, 

wait 10 seconds

, then 

insert a new battery.  

Recommended batteries:  

Duracell DL123A, Huiderui CR123A, 

Panasonic CR123A, Resideo 466  

  Place the front and back housings together 

and slide them together. 

BATTERY CAUTION

: Risk of fire, explosion 

and burns. Do not recharge, disassemble, heat 

above 212°F (100°C) or incinerate. Dispose of 

used batteries properly. Keep away from 

children. 

NOTE

:  Constant exposure to high or low 

temperature or high humidity may reduce 

battery life.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 