MAINTENANCE
3-3
ENGINE OIL LEVEL CHECK
Place the generator on a level surface.
Open the oil maintenance cover (1).
Remove the oil filler cap (2), and wipe the oil level
gauge clean.
Insert the oil filler cap without screwing it into the oil filler
neck (3).
Remove the oil filler cap and check the oil level shown
on the oil level gauge.
If the oil level is low, fill with the recommended oil to the
upper level of the oil filler neck.
Oil is a major factor affecting performance and service
life. Use 4-stroke automotive detergent oil.
SAE 10W-30 is recommended for general use. Other
viscosities shown in the chart may be used when the
average temperature in your area is within the
recommended range.
Tighten the oil filler cap securely.
Reinstall the oil maintenance cover.
ENGINE OIL CHANGE
Drain the engine oil while the engine is warm. Warm oil
drains quickly and completely.
Place the generator on a level surface.
Open the oil maintenance cover.
Remove the oil drain plug (1) from the under cover.
Recommended oil:
SAE10W-30 API service classification SE or later
(1)
(3)
UPPER LEVEL
(2)
(3)
SAE VISCOSITY GRADES
AMBIENT TEMPERATURE