IGNITION SYSTEM
9-8
IGNITION CONTROL MODULE
INSPECTION
Remove the control panel (page 8-8).
Check for continuity between the terminals according to
the table below.
• Some testers have reverse polarity.
Unit:
Ω
Terminal number
1
2
3
4
5
6
7
8
9
10
Termin
a
l numbe
r
1
–
1k – 50k
1k – 50k
20k – 500k
1k – 50k
50k – 500k
2
1k – 50k
–
1k – 50k
20k – 500k
1k – 50k
50k – 500k
3
1k – 50k
1k – 50k
–
20k – 500k
1k – 50k
50k – 500k
4
20k – 500k 20k – 500k 20k – 500k
–
50k – 500k
1k – 50k
50k – 500k
5
50k – 500k 50k – 500k 50k – 500k
–
10k – 200k 200k – 1M
6
10k – 200k 10k – 200k 10k – 200k
10k – 200k
–
20k – 500k
7
50k – 500k 50k – 500k 50k – 500k
50k – 500k 20k – 500k
–
8
–
9
–
10
30k – 500k 30k – 500k 30k – 500k
50k – 500k 10k – 200k 200k – 1M
–